8 resultados para on-ramp queue estimation
em Aston University Research Archive
Resumo:
Recently within the machine learning and spatial statistics communities many papers have explored the potential of reduced rank representations of the covariance matrix, often referred to as projected or fixed rank approaches. In such methods the covariance function of the posterior process is represented by a reduced rank approximation which is chosen such that there is minimal information loss. In this paper a sequential framework for inference in such projected processes is presented, where the observations are considered one at a time. We introduce a C++ library for carrying out such projected, sequential estimation which adds several novel features. In particular we have incorporated the ability to use a generic observation operator, or sensor model, to permit data fusion. We can also cope with a range of observation error characteristics, including non-Gaussian observation errors. Inference for the variogram parameters is based on maximum likelihood estimation. We illustrate the projected sequential method in application to synthetic and real data sets. We discuss the software implementation and suggest possible future extensions.
Resumo:
We analyse the performance persistence of Islamic and Socially Responsible Investment (SRI) mutual funds. We adopt a multi-stage strategy in which, in the first stage, partial frontiers’ approaches are considered to measure the performance of the different funds in the sample. In the second stage, the results yielded by the partial frontiers are plugged into different investment strategies based on a recursive estimation methodology whose persistence performance is evaluated in the third stage of the analysis. Results indicate that, for both types of funds, performance persistence actually exists, but only for the worst and, most notably, best funds. This result is robust not only across methods (and different choices of tuning parameters within each method) but also across both SRI and Islamic funds—although in the case of the latter persistence was stronger for the best funds. The persistence of SRI and Islamic funds represents an important result for investors and the market, since it provides information on both which funds to invest in and which funds to avoid. Last but not least, the use of the aforementioned techniques in the context of mutual funds could also be of interest for the non-conclusive literature.
Foveation time measure in Congenital Nystagmus through second order approximation of the slow phases
Resumo:
Congenital Nystagmus (CN) is an ocular-motor disorder characterised by involuntary, conjugated ocular oscillations, and its pathogenesis is still unknown. The pathology is de fined as "congenital" from the onset time of its arise which could be at birth or in the first months of life. Visual acuity in CN subjects is often diminished due to nystagmus continuous oscillations, mainly on the horizontal plane, which disturb image fixation on the retina. However, during short periods in which eye velocity slows down while the target image is placed onto the fovea (called foveation intervals) the image of a given target can still be stable, allowing a subject to reach a higher visual acuity. In CN subjects, visual acuity is usually assessed both using typical measurement techniques (e.g. Landolt C test) and with eye movement recording in different gaze positions. The offline study of eye movement recordings allows physicians to analyse nystagmus main features such as waveform shape, amplitude and frequency and to compute estimated visual acuity predictors. This analytical functions estimates the best corrected visual acuity using foveation time and foveation position variability, hence a reliable estimation of this two parameters is a fundamental factor in assessing visual acuity. This work aims to enhance the foveation time estimation in CN eye movement recording, computing a second order approximation of the slow phase components of nystag-mus oscillations. About 19 infraredoculographic eye-movement recordings from 10 CN subjects were acquired and the visual acuity assessed with an acuity predictor was compared to the one measured in primary position. Results suggest that visual acuity measurements based on foveation time estimation obtained from interpolated data are closer to value obtained during Landolt C tests. © 2010 IEEE.
Resumo:
Typical Double Auction (DA) models assume that trading agents are one-way traders. With this limitation, they cannot directly reflect the fact individual traders in financial markets (the most popular application of double auction) choose their trading directions dynamically. To address this issue, we introduce the Bi-directional Double Auction (BDA) market which is populated by two-way traders. Based on experiments under both static and dynamic settings, we find that the allocative efficiency of a static continuous BDA market comes from rational selection of trading directions and is negatively related to the intelligence of trading strategies. Moreover, we introduce Kernel trading strategy designed based on probability density estimation for general DA market. Our experiments show it outperforms some intelligent DA market trading strategies. Copyright © 2013, International Foundation for Autonomous Agents and Multiagent Systems (www.ifaamas.org). All rights reserved.
Resumo:
In developing neural network techniques for real world applications it is still very rare to see estimates of confidence placed on the neural network predictions. This is a major deficiency, especially in safety-critical systems. In this paper we explore three distinct methods of producing point-wise confidence intervals using neural networks. We compare and contrast Bayesian, Gaussian Process and Predictive error bars evaluated on real data. The problem domain is concerned with the calibration of a real automotive engine management system for both air-fuel ratio determination and on-line ignition timing. This problem requires real-time control and is a good candidate for exploring the use of confidence predictions due to its safety-critical nature.
Resumo:
In many models of edge analysis in biological vision, the initial stage is a linear 2nd derivative operation. Such models predict that adding a linear luminance ramp to an edge will have no effect on the edge's appearance, since the ramp has no effect on the 2nd derivative. Our experiments did not support this prediction: adding a negative-going ramp to a positive-going edge (or vice-versa) greatly reduced the perceived blur and contrast of the edge. The effects on a fairly sharp edge were accurately predicted by a nonlinear multi-scale model of edge processing [Georgeson, M. A., May, K. A., Freeman, T. C. A., & Hesse, G. S. (in press). From filters to features: Scale-space analysis of edge and blur coding in human vision. Journal of Vision], in which a half-wave rectifier comes after the 1st derivative filter. But we also found that the ramp affected perceived blur more profoundly when the edge blur was large, and this greater effect was not predicted by the existing model. The model's fit to these data was much improved when the simple half-wave rectifier was replaced by a threshold-like transducer [May, K. A. & Georgeson, M. A. (2007). Blurred edges look faint, and faint edges look sharp: The effect of a gradient threshold in a multi-scale edge coding model. Vision Research, 47, 1705-1720.]. This modified model correctly predicted that the interaction between ramp gradient and edge scale would be much larger for blur perception than for contrast perception. In our model, the ramp narrows an internal representation of the gradient profile, leading to a reduction in perceived blur. This in turn reduces perceived contrast because estimated blur plays a role in the model's estimation of contrast. Interestingly, the model predicts that analogous effects should occur when the width of the window containing the edge is made narrower. This has already been confirmed for blur perception; here, we further support the model by showing a similar effect for contrast perception. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
Motivation: In any macromolecular polyprotic system - for example protein, DNA or RNA - the isoelectric point - commonly referred to as the pI - can be defined as the point of singularity in a titration curve, corresponding to the solution pH value at which the net overall surface charge - and thus the electrophoretic mobility - of the ampholyte sums to zero. Different modern analytical biochemistry and proteomics methods depend on the isoelectric point as a principal feature for protein and peptide characterization. Protein separation by isoelectric point is a critical part of 2-D gel electrophoresis, a key precursor of proteomics, where discrete spots can be digested in-gel, and proteins subsequently identified by analytical mass spectrometry. Peptide fractionation according to their pI is also widely used in current proteomics sample preparation procedures previous to the LC-MS/MS analysis. Therefore accurate theoretical prediction of pI would expedite such analysis. While such pI calculation is widely used, it remains largely untested, motivating our efforts to benchmark pI prediction methods. Results: Using data from the database PIP-DB and one publically available dataset as our reference gold standard, we have undertaken the benchmarking of pI calculation methods. We find that methods vary in their accuracy and are highly sensitive to the choice of basis set. The machine-learning algorithms, especially the SVM-based algorithm, showed a superior performance when studying peptide mixtures. In general, learning-based pI prediction methods (such as Cofactor, SVM and Branca) require a large training dataset and their resulting performance will strongly depend of the quality of that data. In contrast with Iterative methods, machine-learning algorithms have the advantage of being able to add new features to improve the accuracy of prediction. Contact: yperez@ebi.ac.uk Availability and Implementation: The software and data are freely available at https://github.com/ypriverol/pIR. Supplementary information: Supplementary data are available at Bioinformatics online.