10 resultados para lateral aberrations

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent functional magnetic resonance imaging (fMRI) investigations of the interaction between cognition and reward processing have found that the lateral prefrontal cortex (PFC) areas are preferentially activated to both increasing cognitive demand and reward level. Conversely, ventromedial PFC (VMPFC) areas show decreased activation to the same conditions, indicating a possible reciprocal relationship between cognitive and emotional processing regions. We report an fMRI study of a rewarded working memory task, in which we further explore how the relationship between reward and cognitive processing is mediated. We not only assess the integrity of reciprocal neural connections between the lateral PFC and VMPFC brain regions in different experimental contexts but also test whether additional cortical and subcortical regions influence this relationship. Psychophysiological interaction analyses were used as a measure of functional connectivity in order to characterize the influence of both cognitive and motivational variables on connectivity between the lateral PFC and the VMPFC. Psychophysiological interactions revealed negative functional connectivity between the lateral PFC and the VMPFC in the context of high memory load, and high memory load in tandem with a highly motivating context, but not in the context of reward alone. Physiophysiological interactions further indicated that the dorsal anterior cingulate and the caudate nucleus modulate this pathway. These findings provide evidence for a dynamic interplay between lateral PFC and VMPFC regions and are consistent with an emotional gating role for the VMPFC during cognitively demanding tasks. Our findings also support neuropsychological theories of mood disorders, which have long emphasized a dysfunctional relationship between emotion/motivational and cognitive processes in depression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research concerns the development and application of an analytical computer program, SAFE-ROC, that models material behaviour and structural behaviour of a slender reinforced concrete column that is part of an overall structure and is subjected to elevated temperatures as a result of exposure to fire. The analysis approach used in SAFE-RCC is non-linear. Computer calculations are used that take account of restraint and continuity, and the interaction of the column with the surrounding structure during the fire. Within a given time step an iterative approach is used to find a deformed shape for the column which results in equilibrium between the forces associated with the external loads and internal stresses and degradation. Non-linear geometric effects are taken into account by updating the geometry of the structure during deformation. The structural response program SAFE-ROC includes a total strain model which takes account of the compatibility of strain due to temperature and loading. The total strain model represents a constitutive law that governs the material behaviour for concrete and steel. The material behaviour models employed for concrete and steel take account of the dimensional changes caused by the temperature differentials and changes in the material mechanical properties with changes in temperature. Non-linear stress-strain laws are used that take account of loading to a strain greater than that corresponding to the peak stress of the concrete stress-strain relation, and model the inelastic deformation associated with unloading of the steel stress-strain relation. The cross section temperatures caused by the fire environment are obtained by a preceding non-linear thermal analysis, a computer program FIRES-T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research has indicated that schematic eyes incorporating aspheric surfaces but lacking gradient index are unable to model ocular spherical aberration and peripheral astigmatism simultaneously. This limits their use as wide-angle schematic eyes. This thesis challenges this assumption by investigating the flexibility of schematic eyes comprising aspheric optical surfaces and homogeneous optical media. The full variation of ocular component dimensions found in human eyes was established from the literature. Schematic eye parameter variants were limited to these dimensions. The levels of spherical aberration and peripheral astigmatism modelled by these schematic eyes were compared to the range of measured levels. These were also established from the literature. To simplify comparison of modelled and measured data, single value parameters were introduced; the spherical aberration function (SAF), and peripheral astigmatism function (PAF). Some ocular components variations produced a wide range of aberrations without exceeding the limits of human ocular components. The effect of ocular component variations on coma was also investigated, but no comparison could be made as no empirical data exists. It was demonstrated that by combined manipulation of a number of parameters in the schematic eyes it was possible to model all levels of ocular spherical aberration and peripheral astigmatism. However, the unique parameters of a human eye could not be obtained in this way, as a number of models could be used to produce the same spherical aberration and peripheral astigmatism, while giving very different coma levels. It was concluded that these schematic eyes are flexible enough to model the monochromatic aberrations tested, the absence of gradient index being compensated for by altering the asphericity of one or more surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate a mixed problem with variable lateral conditions for the heat equation that arises in modelling exocytosis, i.e. the opening of a cell boundary in specific biological species for the release of certain molecules to the exterior of the cell. The Dirichlet condition is imposed on a surface patch of the boundary and this patch is occupying a larger part of the boundary as time increases modelling where the cell is opening (the fusion pore), and on the remaining part, a zero Neumann condition is imposed (no molecules can cross this boundary). Uniform concentration is assumed at the initial time. We introduce a weak formulation of this problem and show that there is a unique weak solution. Moreover, we give an asymptotic expansion for the behaviour of the solution near the opening point and for small values in time. We also give an integral equation for the numerical construction of the leading term in this expansion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the effects of ocular lubricants on higher order aberrations in normal and self-diagnosed dry eyes. Methods: Unpreserved hypromellose drops, Tears Again™ liposome spray and a combination of both were administered to the right eye of 24 normal and 24 dry eye subjects following classification according to a 5 point questionnaire. Total ocular higher order aberrations, coma, spherical aberration and Strehl ratios for higher order aberrations were measured using the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) at baseline, immediately after application and after 60. min. The aberration data were analyzed over a 5. mm natural pupil using Zernike polynomials. Each intervention was assessed on a separate day and comfort levels were recorded before and after application. Corneal staining was assessed and product preference recorded after the final measurement for each intervention. Results: Hypromellose drops caused an increase in total higher order aberrations (p= <0.01 in normal and dry eyes) and a reduction in Strehl ratio (normal eyes: p= <0.01, dry eyes p= 0.01) immediately after instillation. There were no significant differences between normal and self-diagnosed dry eyes for response to intervention and no improvement in visual quality or reduction in higher order aberrations after 60. min. Differences in comfort levels failed to reach statistical significance. Conclusion: Combining treatments does not offer any benefit over individual treatments in self-diagnosed dry eyes and no individual intervention reached statistical significance. Symptomatic subjects with dry eye and no corneal staining reported an improvement in comfort after using lubricants. © 2013 British Contact Lens Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In relaxed wakefulness, the EEG exhibits robust rhythms in the alpha band (8-13 Hz), which decelerate to theta (approximately 2-7 Hz) frequencies during early sleep. In animal models, these rhythms occur coherently with synchronized activity in the thalamus. However, the mechanisms of this thalamic activity are unknown. Here we show that, in slices of the lateral geniculate nucleus maintained in vitro, activation of the metabotropic glutamate receptor (mGluR) mGluR1a induces synchronized oscillations at alpha and theta frequencies that share similarities with thalamic alpha and theta rhythms recorded in vivo. These in vitro oscillations are driven by an unusual form of burst firing that is present in a subset of thalamocortical neurons and are synchronized by gap junctions. We propose that mGluR1a-induced oscillations are a potential mechanism whereby the thalamus promotes EEG alpha and theta rhythms in the intact brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of propylsulfonic (MCM-SOH) and octyl co-functionalised propylsulfonic (MCM-Oc-SOH) catalysts have been prepared by post modification of MCM-41 with mercaptopropyltrimethoxysilane (MPTS) to achieve SOH surface coverages spanning the range 0.12-1 monolayer. Within the MCM-Oc-SOH series, samples with submonolayer MPTS coverages were further grafted with octyltrimethoxysilane to cap bare hydroxyl sites and tune the hydrophobicity of the support. For the MCM-SO H series NH calorimetry revealed acid strength increases as a function of sulfonic acid loading, with -ΔH(NH ) increasing from 87 to 118 kJ mol. In contrast, MCM-Oc-SOH exhibits a dramatic enhancement of acid strength for submonolayer SOH coverages, with -ΔH(NH ) found to increase to 103 kJ mol. In line with these acid strength measurements the per-site activity of the MCM-SOH series in the esterification of butanol with acetic acid was found to increase with SOH content. Incorporation of octyl groups further promotes esterification activity of all the samples within the MCM-Oc-SOH series, such that the turn over frequency of the sample with the lowest loading of SOH more than doubles. Molecular dynamic simulations indicate that the interaction of isolated sulfonic acid groups with the pore walls is the primary cause of the decrease in acid strength and activity of submonolayer samples within the MCM-SOH series. Incorporation of octyl groups results in a combination of increased hydrophobicity and lateral interactions between adjacent sulfonic acid head groups, resulting in a striking enhancement of acid strength and esterification activity. © 2010 The Royal Society of Chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim was to assess the potential association between entrance pupil location relative to the coaxially sighted corneal light reflex (CSCLR) and the progression of myopia in children fitted with orthokeratology (OK) contact lenses. Additionally, whether coma aberration induced by decentration of the entrance pupil centre relative to the CSCLR, as well as following OK treatment, is correlated with the progression of myopia, was also investigated. Methods: Twenty-nine subjects aged six to 12years and with myopia of -0.75 to -4.00 DS and astigmatism up to 1.00DC were fitted with OK contact lenses. Measurements of axial length and corneal topography were taken at six-month intervals over a two-year period. Additionally, baseline and three-month topographic outputs were taken as representative of the pre- and post-orthokeratology treatment status. Pupil centration relative to the CSCLR and magnitude of associated corneal coma were derived from corneal topographic data at baseline and after three months of lens wear. Results: The centre of the entrance pupil was located superio-temporally to the CSCLR both pre- (0.09±0.14 and -0.10±0.15mm, respectively) and post-orthokeratology (0.12±0.18 and -0.09±0.15mm, respectively) (p>0.05). Entrance pupil location pre- and post-orthokeratology lens wear was not significantly associated with the two-year change in axial length (p>0.05). Significantly greater coma was found at the entrance pupil centre compared with CSCLR both pre- and post-orthokeratology lens wear (both p<0.05). A significant increase in vertical coma was found with OK lens wear compared to baseline (p<0.001) but total root mean square (RMS) coma was not associated with the change in axial length (all p>0.05). Conclusion: Entrance pupil location relative to the CSCLR was not significantly affected by either OK lens wear or an increase in axial length. Greater magnitude coma aberrations found at the entrance pupil centre in comparison to the CSCLR might be attributed to centration of orthokeratological treatments at the CSCLR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in C3, C4, C4, root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.