24 resultados para interferometry
em Aston University Research Archive
Resumo:
We describe an all-fibre, passive scheme for making extended range interferometric measurements based on the dual wavelength technique. The coherence tuned interferometer network is illuminated with a single superfluorescent fibre source at 1.55 µm and the two wavelengths are synthesised at the output by means of chirped fibre Bragg gratings. We demonstrate an unambiguous sensing range of 270 µm, with a dynamic range of 2.7 × 10 5.
Resumo:
We describe how an acousto-optic tunable filter can be used to both demultiplex the signals from multiple fibre Bragg grating sensors and simultaneously provide wide bandwidth signal demodulation in a system using interferometric wavelength shift detection. In an experimental demonstration, the approach provided a noise limited strain resolution of 24.9 n epsilon Hz(-1/ 2) at 15 Hz.
Resumo:
An optical coherence tomography (OCT) system to produce both longitudinal and transversal images of the in vivo human eye is presented. For the first time, OCT transversal images collected from the living eye at 50-µm depth steps show details unobtainable with the state-of-the-art scanning laser ophthalmoscope. Images of up to 3×3?mm are produced from the retina in less than a second. For images larger than 1.6×1.6?mm, a path modulation is introduced by the galvanometric scanning mirror and is used as an effective phase modulation method.
Resumo:
We describe in the letter a technique for making extended-range interferometric measurements with a coherence multiplexed system by means of a variation on the dual-wavelength technique. The interferometer is illuminated with a single source and the two wavelengths are synthesised at the output by means of an interference filter.
Resumo:
Progressive addition spectacle lenses (PALs) have now become the method of choice for many presbyopic individuals to alleviate the visual problems of middle-age. Such lenses are difficult to assess and characterise because of their lack of discrete geographical locators of their key features. A review of the literature (mostly patents) describing the different designs of these lenses indicates the range of approaches to solving the visual problem of presbyopia. However, very little is published about the comparative optical performance of these lenses. A method is described here based on interferometry for the assessment of PALs, with a comparison of measurements made on an automatic focimeter. The relative merits of these techniques are discussed. Although the measurements are comparable, it is considered that the interferometry method is more readily automated, and would be ultimately capable of producing a more rapid result.
Resumo:
We describe an all-fibre, passive scheme for making extended range interferometric measurements based on the dual wavelength technique. The coherence tuned interferometer network is illuminated with a single superfluorescent fibre source at 1.55 μm and the two wavelengths are synthesised at the output by means of chirped fibre Bragg gratings. We demonstrate an unambiguous sensing range of 270 μm, with a dynamic range of 2.7 × 105.
Resumo:
We describe how an acousto-optic tunable filter can be used to both demultiplex the signals from multiple fibre Bragg grating sensors and simultaneously provide wide bandwidth signal demodulation in a system using interferometric wavelength shift detection. In an experimental demonstration, the approach provided a noise limited strain resolution of 24.9 nε Hz -1/2 at 15 Hz. © 2007 IOP Publishing Ltd.
Resumo:
An optical coherence tomography (OCT) system to produce both longitudinal and transversal images of the in vivo human eye is presented. For the first time, OCT transversal images collected from the living eye at 50-µm depth steps show details unobtainable with the state-of-the-art scanning laser ophthalmoscope. Images of up to 3×3?mm are produced from the retina in less than a second. For images larger than 1.6×1.6?mm, a path modulation is introduced by the galvanometric scanning mirror and is used as an effective phase modulation method.
Resumo:
The aim of the research work described in this thesis was to investigate the interrogation of fibre optic sensors using "off the shelf optical components and equipment developed mainly for the telecommunications industry. This provides a cost effective way of bringing fibre optic sensor systems to within the price range of their electro-mechanical counterparts. The research work focuses on the use of an arrayed waveguide grating, an acousto-optic tuneable filter and low-coherence interferometry to measure dynamic strain and displacement using fibre Bragg grating and interferometric sensors. Based on the intrinsic properties of arrayed waveguide gratings and acousto-optic tuneable filters used in conjunction with interferometry, fibre Bragg gratings and interferometric sensors a number of novel fibre optic sensor interrogation systems have been realised. Special single mode fibre, namely, high-birefringence fibre has been employed to implement a dual-beam interrogating interferometer. The first interrogation scheme is based on an optical channel monitor, which is an arrayed waveguide grating with integral photo-detectors providing a number of amplified electrical outputs. It is used to interrogate fibre Bragg grating and interferometric sensors. Using the properties of polarisation maintainability in high-birefringent fibre an interrogating interferometer was realised by winding a length of the fibre around a piezoelectric modulator generating a low-frequency carrier signal. The system was used to interrogate both fibre Bragg grating and interferometric sensors. Finally, the use of an acousto-optic tuneable filter is employed to interrogate fibre Bragg gratings. The device is used to generate a very high frequency carrier signal at the output of an optical interferometer.
Resumo:
PURPOSE. A methodology for noninvasively characterizing the three-dimensional (3-D) shape of the complete human eye is not currently available for research into ocular diseases that have a structural substrate, such as myopia. A novel application of a magnetic resonance imaging (MRI) acquisition and analysis technique is presented that, for the first time, allows the 3-D shape of the eye to be investigated fully. METHODS. The technique involves the acquisition of a T2-weighted MRI, which is optimized to reveal the fluid-filled chambers of the eye. Automatic segmentation and meshing algorithms generate a 3-D surface model, which can be shaded with morphologic parameters such as distance from the posterior corneal pole and deviation from sphericity. Full details of the method are illustrated with data from 14 eyes of seven individuals. The spatial accuracy of the calculated models is demonstrated by comparing the MRI-derived axial lengths with values measured in the same eyes using interferometry. RESULTS. The color-coded eye models showed substantial variation in the absolute size of the 14 eyes. Variations in the sphericity of the eyes were also evident, with some appearing approximately spherical whereas others were clearly oblate and one was slightly prolate. Nasal-temporal asymmetries were noted in some subjects. CONCLUSIONS. The MRI acquisition and analysis technique allows a novel way of examining 3-D ocular shape. The ability to stratify and analyze eye shape, ocular volume, and sphericity will further extend the understanding of which specific biometric parameters predispose emmetropic children subsequently to develop myopia. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Some critical aspects of a new kind of on-line measurement technique for micro and nanoscale surface measurements are described. This attempts to use spatial light-wave scanning to replace mechanical stylus scanning, and an optical fibre interferometer to replace optically bulky interferometers for measuring the surfaces. The basic principle is based on measuring the phase shift of a reflected optical signal. Wavelength-division-multiplexing and fibre Bragg grating techniques are used to carry out wavelength-to-field transformation and phase-to-depth detection, allowing a large dynamic measurement ratio (range/resolution) and high signal-to-noise ratio with remote access. In effect the paper consists of two parts: multiplexed fibre interferometry and remote on-machine surface detection sensor (an optical dispersive probe). This paper aims to investigate the metrology properties of a multiplexed fibre interferometer and to verify its feasibility by both theoretical and experimental studies. Two types of optical probes, using a dispersive prism and a blazed grating, respectively, are introduced to realize wavelength-to-spatial scanning.
Resumo:
The thesis aims to define further the biometric correlates in anisometropic eyes in order to provide a structural foundation for propositions concerning the development of ametropia.Biometric data are presented for 40 anisometropes and 40 isometropic controls drawn from Caucasian and Chinese populations.The principal finding was that the main structural correlate of myopia is an increase in axial rather than equatorial dimensions of the posterior globe. This finding has not been previously reported for in vivo work on humans. The computational method described in the thesis is a more accessible method for determination of eye shape than current imaging techniques such as magnetic resonance imaging or laser Doppler interferometry (LDI). Retinal contours derived from LDI and computation were shown to be closely matched. Corneal topography revealed no differences in corneal characteristics in anisometropic eyes, which supports the finding that anisometropia arises from differences in vitreous chamber depth.The corollary to axial expansion in myopia, that is retinal stretch in central regions of the posterior pole, was investigated by measurement of disc-to-fovea distances (DFD) using a scanning laser ophthalmoscope. DFD was found to increase with increased myopia, which demonstrates the primary contribution made by posterior central regions of the globe to axial expansion.The ocular pulse volume and choroidal blood flow, measured with the Ocular Blood Flow Tonograph, were found to be reduced in myopia; the reductions were found to be significantly correlated with vitreous chamber depth. The thesis includes preliminary data on whether the relationship arises from the influx of a blood bolus into eyes of different posterior volumes or represents actual differences in choroidal blood flow.The results presented in this thesis show the utility of computed retinal contour and demonstrate that the structural correlate of myopia is axial rather than equatorial expansion of the vitreous chamber. The technique is suitable for large population studies and its relative simplicity makes it feasible for longitudinal studies on the development of ametropia in, for example, children.