9 resultados para index evaluation

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microbiological diagnosis of catheter-related bloodstream infection (CR-BSI) is often based on isolation of indistinguishable micro-organisms from an explanted catheter tip and blood culture, confirmed by antibiograms. Whether phenotypic identification of coagulase-negative staphylococci (CoNS) allows an accurate diagnosis of CR-BSI to be established was evaluated. Eight patients with a diagnosis of CR-BSI had CoNS isolated from pure blood cultures and explanted catheter tips which were considered as indistinguishable strains by routine microbiological methods. For each patient, an additional three colonies of CoNS isolated from the blood and five from the catheter tip were subcultured and further characterized by antibiogram profiles, analytical profile index (API) biotyping and PFGE. PFGE distinguished more strains of CoNS compared to API biotyping or antibiograms (17, 10 and 11, respectively). By PFGE, indistinguishable micro-organisms were only isolated from pure blood and catheter tip cultures in four out of eight (50%) patients thus supporting the diagnosis of CR-BSI. In another patient, indistinguishable micro-organisms were identified in both cultures; however, other strains of CoNS were also present. The remaining three patients had multiple strains of CoNS, none of which were indistinguishable in the tip and blood cultures, thus questioning the diagnosis of CR-BSI. Phenotypic characterization of CoNS lacked discriminatory power. Current routine methods of characterizing a limited number of pooled colonies may generate misleading results as multiple strains may be present in the cultures. Multiple colonies should be studied using a rapid genotypic characterization method to confirm or refute the diagnosis of CR-BSI. © 2007 SGM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report details an evaluation of the My Choice Weight Management Programme undertaken by a research team from the School of Pharmacy at Aston University. The My Choice Weight Management Programme is delivered through community pharmacies and general practitioners (GPs) contracted to provide services by the Heart of Birmingham teaching Primary Care Trust. It is designed to support individuals who are ‘ready to change’ by enabling the individual to work with a trained healthcare worker (for example, a healthcare assistant, practice nurse or pharmacy assistant) to develop a care plan designed to enable the individual to lose 5-10% of their current weight. The Programme aims to reduce adult obesity levels; improve access to overweight and obesity management services in primary care; improve diet and nutrition; promote healthy weight and increased levels of physical activity in overweight or obese patients; and support patients to make lifestyle changes to enable them to lose weight. The Programme is available for obese patients over 18 years old who have a Body Mass Index (BMI) greater than 30 kg/m2 (greater than 25 kg/m2 in Asian patients) or greater than 28 kg/m2 (greater than 23.5 kg/m2 in Asian patients) in patients with co-morbidities (diabetes, high blood pressure, cardiovascular disease). Each participant attends weekly consultations over a twelve session period (the final iteration of these weekly sessions is referred to as ‘session twelve’ in this report). They are then offered up to three follow up appointments for up to six months at two monthly intervals (the final of these follow ups, taking place at approximately nine months post recruitment, is referred to as ‘session fifteen’ in this report). A review of the literature highlights the dearth of published research on the effectiveness of primary care- or community-based weight management interventions. This report may help to address this knowledge deficit. A total of 451 individuals were recruited on to the My Choice Weight Management Programme. More participants were recruited at GP surgeries (n=268) than at community pharmacies (n=183). In total, 204 participants (GP n=102; pharmacy n=102) attended session twelve and 82 participants (GP n=22; pharmacy 60) attended session fifteen. The unique demographic characteristics of My Choice Weight Management Programme participants – participants were recruited from areas with high levels of socioeconomic deprivation and over four-fifths of participants were from Black and Minority Ethnic groups; populations which are traditionally underserved by healthcare interventions – make the achievements of the Programme particularly notable. The mean weight loss at session 12 was 3.8 kg (equivalent to a reduction of 4.0% of initial weight) among GP surgery participants and 2.4 kg (2.8%) among pharmacy participants. At session 15 mean weight loss was 2.3 kg (2.2%) among GP surgery participants and 3.4 kg (4.0%) among pharmacy participants. The My Choice Weight Management Programme improved the general health status of participants between recruitment and session twelve as measured by the validated SF-12 questionnaire. While cost data is presented in this report, it is unclear which provider type delivered the Programme more cost-effectively. Attendance rates on the Programme were consistently better among pharmacy participants than among GP participants. The opinions of programme participants (both those who attended regularly and those who failed to attend as expected) and programme providers were explored via semi-structured interviews and, in the case of the participants, a selfcompletion postal questionnaire. These data suggest that the Programme was almost uniformly popular with both the deliverers of the Programme and participants on the Programme with 83% of questionnaire respondents indicating that they would be happy to recommend the Programme to other people looking to lose weight. Our recommendations, based on the evidence provided in this report, include: a. Any consideration of an extension to the study also giving comparable consideration to an extension of the Programme evaluation. The feasibility of assigning participants to a pharmacy provider or a GP provider via a central allocation system should also be examined. This would address imbalances in participant recruitment levels between provider type and allow for more accurate comparison of the effectiveness in the delivery of the Programme between GP surgeries and community pharmacies by increasing the homogeneity of participants at each type of site and increasing the number of Programme participants overall. b. Widespread dissemination of the findings from this review of the My Choice Weight Management Project should be undertaken through a variety of channels. c. Consideration of the inclusion of the following key aspects of the My Choice Weight Management Project in any extension to the Programme: i. The provision of training to staff in GP surgeries and community pharmacies responsible for delivery of the Programme prior to patient recruitment. ii. Maintaining the level of healthcare staff input to the Programme. iii. The regular schedule of appointments with Programme participants. iv. The provision of an increased variety of printed material. d. A simplification of the data collection method used by the Programme commissioners at the individual Programme delivery sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A standardised defocus area metric and reading performance index metric were devised for the evaluation of the range of focus and the reading ability of subjects implanted with presbyopic correcting IOLs. The range of clear vision after implantation of an MIOL is extended by a second focal point; however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed to allow the accurate assessment of IOL rotation, which was used to determine the rotational and positional stability of a closed loop haptic IOL. A new commercially available biometry device was validated for use with subjects prior to cataract surgery. The optical low coherence reflectometry instrument proved to be a valid method for assessing ocular biometry and covered a wider range of ocular parameters in comparison with previous instruments. The advantages of MIOLs were shown to include an extended range of clear vision translating into greater reading ability. However, an increased prevalence of dysphotopsia was shown with a bespoke halometer, which was dependent on the MIOL optic design. Implantation of a single optic accommodating IOL did not improve reading ability but achieved high subjective ratings of near vision. The closed-loop haptic IOL displayed excellent rotational stability in the late period but relatively poor rotational stability in the early period post implantation. The orientation error was compounded by the high frequency of positional misalignment leading to an extensive overall misalignment of the IOL. This thesis demonstrates the functionality of new IOL lens designs and the importance of standardised testing methods, thus providing a greater understanding of the consequences of implanting these IOLs. Consequently, the findings of the thesis will influence future designs of IOLs and testing methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the work undertaken in the Scholarly Ontologies Project. The aim of the project has been to develop a computational approach to support scholarly sensemaking, through interpretation and argumentation, enabling researchers to make claims: to describe and debate their view of a document's key contributions and relationships to the literature. The project has investigated the technicalities and practicalities of capturing conceptual relations, within and between conventional documents in terms of abstract ontological structures. In this way, we have developed a new kind of index to distributed digital library systems. This paper reports a case study undertaken to test the sensemaking tools developed by the Scholarly Ontologies project. The tools used were ClaiMapper, which allows the user to sketch argument maps of individual papers and their connections, ClaiMaker, a server on which such models can be stored and saved, which provides interpretative services to assist the querying of argument maps across multiple papers and ClaimFinder, a novice interface to the search services in ClaiMaker.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fabrication of gratings has gone a long way since the onset by Kenneth Hill in 1976. Basic fabrication techniques such as holographic and phase-mask which have distinguishing advantages (variable wavelength, and high repeatability consecutively) have since been modified in an effort to combine the advantages of both methods. These basic methods are inherently simple and have few controls, they have been combined and modified over time to enable the possibility of fabricating gratings with complex modulation index and phase profiles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fabrication of gratings has gone a long way since the onset by Kenneth Hill in 1976. Basic fabrication techniques such as holographic and phase-mask which have distinguishing advantages (variable wavelength, and high repeatability consecutively) have since been modified in an effort to combine the advantages of both methods. These basic methods are inherently simple and have few controls, they have been combined and modified over time to enable the possibility of fabricating gratings with complex modulation index and phase profiles.