8 resultados para front of pack

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Policy towards planning presents scholars of politics and public policy with a significant puzzle. Since 1947, there has been a surprising level of stability in the system used to plan the use of land. On the other hand, there has been growing evidence that insufficient land has been released for development. The paper considers the question why, in spite of the planning system demonstrably failing to allocate sufficient land, fundamental reform of the system has not been achieved. In answering the question, the paper considers in particular attempts at reform under the Labour governments from 1997 to 2010. It argues that there is an interplay of interests, ideas and institutions: public attitudes, the interests of certain sections of the population, and institutions which are responsive to these attitudes and interests combined to stymie policy reform. As a consequence, radical reform was not achieved, and the paper concludes that attempt to find a technical “fix” to the planning system are unlikely to succeed. A diagnosis recognising the political and distributive nature of the problem will be required.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE. Strabismic amblyopia is typically associated with several visual deficits, including loss of contrast sensitivity in the amblyopic eye and abnormal binocular vision. Binocular summation ratios (BSRs) are usually assessed by comparing contrast sensitivity for binocular stimuli (sens BIN) with that measured in the good eye alone (sensGOOD), giving BSR = sensBIN/sensGOOD. This calculation provides an operational index of clinical binocular function, but does not assess whether neuronal mechanisms for binocular summation of contrast remain intact. This study was conducted to investigate this question. METHODS. Horizontal sine-wave gratings were used as stimuli (3 or 9 cyc/deg; 200 ms), and the conventional method of assessment (above) was compared with one in which the contrast in the amblyopic eye was adjusted (normalized) to equate monocular sensitivities. RESULTS. In nine strabismic amblyopes (mean age, 32 years), the results confirmed that the BSR was close to unity when the conventional method was used (little or no binocular advantage), but increased to approximately √2 or higher when the normalization method was used. The results were similar to those for normal control subjects (n = 3; mean age, 38 years) and were consistent with the physiological summation of contrast between the eyes. When the normal observers performed the experiments with a neutral-density (ND) filter in front of one eye, their performance was similar to that of the amblyopes in both methods of assessment. CONCLUSIONS. The results indicate that strabismic amblyopes have mechanisms for binocular summation of contrast and that the amblyopic deficits of binocularity can be simulated with an ND filter. The implications of these results for best clinical practice are discussed. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study determined whether the radial growth of lobes of the foliose lichen Parmelia conspersa (Ehrh. ex Ach.)Ach. was influenced by the radial growth and morphology of their closest neighbours and whether such interactions influence thallus symmetry. The radial growth and morphology of a sample of adjacent lobes from six thalli was measured. Positive correlations were observed between radial growth and lobe width in three thalli and with the degree of bifurcation of the lobe in two thalli. Negative correlations between the radial growth of adjacent lobes were observed in four thalli suggesting that faster growing lobes may inhibit the growth of their neighbours.Lobes glued next to individual lobes had no signifiacnt effect on the radial growth of wide or narrow lobes. Lobes glued 1-2 mm in front of their neighbours exhibited an intital phase of increased radial growth and then a phase of slower growth. Radial growth decreased when the lobes were glued 2 mm behind their neighbours and these lobes were essentially eliminated by the growth of the adjacent lobes. The data suggest that lobe interactions may incresae lobe growth variation within a thallus. However, the decrease in radial growth of lobes which protrude from the margin and the elimination of slower growing lobes may help to maintain thallus symmetry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Lithofacies distribution indicates that the Much Wenlock Limestone Formation of England and South Wales was desposited on a shelf which was flat and gently subsiding in the north, but topographically variable in the south. Limestone deposition in the north began with 12m of alga-rich limestone, which formed an upward shoaling sequence. Deepening then led to deposition of calcareous silty mudstones on the northern shelf. The remainder of the formation in this area formed during a shelf-wide regression, culminating in the production of an E to W younging sandbody. Lithofacies distribution on the southern shelf was primarily controlled by local subsidence. Six bedded lithofacies are recognised which contain 14 brachiopod/bryozoan dominated assemblages, of which 11 are in situ and three consist of reworked fossils. Microfacies analysis is necessary to distinguish assemblages which reflect original communities from those which reflect sedimentary processes. Turbulence, substrate-type, ease of feeding and other organisms in the environment controlled faunal distribution. Reefs were built dominantly by corals, stromatoporoids, algae and crinoids. Coral/stromatoporoid (Type A) reefs are common, particularly on the northern shelf, where they formed in response to shallowing, ultimately growing in front of the advancing carbonate sandbody. Algae dominate Type B and Type C reefs, reflecting growth in areas of poor water circulation. Lithification of the formation began in the marine-phreatic environment with precipitation of aragonite and high Mg calcite, which was subsequently altered to turbid low Mg calcite. Younger clear spars post-date secondary void formation. The pre-compactional clear spars have features which resemble the products of meteoric water diagenesis, but freshwater did not enter the formation at this time. The pre-compactional spars were precipitated by waters forced from the surrounding silty mudstones at shallow burial depths. Late diagenetic products are stylolites, compaction fractures and burial cements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To assess the validity and repeatability of the Aston Halometer. Setting University clinic, United Kingdom. Design Prospective, repeated-measures experimental study. Methods The halometer comprises a bright light-emitting-diode (LED) glare source in the center of an iPad4. Letters subtending 0.21° (∼0.3 logMAR) were moved centrifugally from the LED in 0.05 degree steps in 8 orientations separated by 45 degrees for each of 4 contrast levels (1000, 500, 100, and 25 Weber contrast units [Cw]) in random order. Bangerter occlusion foils were inserted in front of the right eye to simulate monocular glare conditions in 20 subjects (mean age 27.7 ± 3.1 years). Subjects were positioned 2 meters from the screen in a dark room with the iPad controlled from an iPhone via Bluetooth operated by the researcher. The C-Quant straylight meter was also used with each of the foils to measure the level of straylight over the retina. Halometry and straylight repeatability was assessed at a second visit. Results Halo size increased with the different occlusion foils and target contrasts (F = 29.564, P <.001) as expected and in a pattern similar to straylight measures (F = 80.655, P <0.001). Lower contrast letters showed better sensitivity but larger glare-obscured areas, resulting in ceiling effects caused by the screen's field-of-view, with 500 Cw being the best compromise. Intraobserver and interobserver repeatability of the Aston Halometer was good (500Cw: 0.84 to 0.93 and 0.53 to 0.73) and similar to the straylight meter. Conclusion The halometer provides a sensitive, repeatable way of quantifying a patient-recognized form of disability glare in multiple orientations to add objectivity to subjectively reported discomfort glare.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to determine whether stereoacuity can be used as an indicator of prism adaptation. In particular, we wanted to know whether the time required for stereoacuity to return to the initial level after viewing through a prism can be used to determine the degree of adaptation. Materials and Methods: Eighteen subjects participated in this study. Stereoacuity and dissociated phoria were determined using the TNO stereotest and the Maddox rod, respectively. Prism vergences were measured using a prism bar. For each participant, prism power equivalent to the blur point of base-in (BI) and base-out (BO) fusional vergence at 40 cm was divided and placed in front of both eyes. At 0, 3, 6, 9 and 12 min after prism introduction, the stereoacuity was measured, and at 0 and 12 min, the heterophoria was measured. Results: The repeated measures ANOVA showed a significant difference between the mean stereoacuity for BI and BO prisms at the different measurement times (p < 0.05). For BO prism, the initial value was different between 0 and 3 min after the prism introduction, whereas for BI prism, a difference in stereoacuity was found between the pre-prism value and the value at 0, 3 and 6 min. The size of the heterophoria with BO and BI prisms was different from 0 to 12 min (p < 0.05). Conclusion: The time required for stereoacuity to return to baseline level was more than 3 min for BO, and more than 6 min for BI prism. In addition, the time required to return to baseline values was not similar for the stereoacuity and heterophoria. The recovery of stereoacuity is slower when adapting to divergence, as when looking from near to far. This implies that stereopsis responds faster to near targets than to distant one, and may precede complete phoria adaptation. © 2014 Informa Healthcare USA, Inc. All rights reserved: reproduction in whole or part not permitted.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper examines a method for locating within a scene a distribution of an absorbing gas using a passive imaging technique. An oscillatory modulation of the angle of a narrowband dielectric filter located in front of a camera imaging a scene, gives rise to an intensity modulation that differs in regions occupied by the absorbing gas. A preliminary low cost system has been constructed from readily available components which demonstrates how the location of gas within a scene can be implemented. Modelling of the system has been carried out, especially highlighting the transmission effects of the dielectric filter upon different regions of the image.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this survey was to review 187 transcripts from the United Kingdom’s General Optical Council (GOC) Disciplinary and Fitness To Practise (FTP) Committee hearings from 2001 to 2011 in order to identify common themes and thereby help practitioners to avoid the more frequently occurring pitfalls that were recorded during this period. The study covered changes in GOC FTP regulations in 2005, which involved a change from a disciplinary to a fitness to practise process. The number of cases was very small compared to the total number of optometrist and dispensing optician registrants, which was 13709 in 2001-02 rising to 18582 in 2010-11. The main findings indicated that between 2001 and 2011 there was a three times greater likelihood that male registrants versus female registrants would be brought in front of a GOC Disciplinary or FTP Committee. In terms of erasures from the GOC registers between 2001 and 2011, male registrants were also more likely to be erased than females. The male: female split for erasures between 2001 and 2011 was five: one, increasing to seven: one when considering the situation post the 2005 GOC FTP rule change. Of the cases brought before the Disciplinary and FTP Committees between 2001 and 2011, it was noted that cases implicating theft and fraud were most frequent representing 27% of hearings examined (17% involving NHS fraud and 10% theft or fraud from an employer). The examination of transcripts revealed other hearings were more complex. These hearings often had a primary reason for the investigation that highlighted further secondary concerns that also required investigation.