9 resultados para film stack design
em Aston University Research Archive
Resumo:
Purpose: Surfactant proteins A, B, C and D complex with (phospho)lipids to produce surfactants which provide low interfacial tensions. It is likely that similar complexation occurs in the tear film and contributes to its low surface tension. Synthetic protein-phospholipid complexes, with styrene maleic anhydrides (SMAs) as the protein analogue, have been shown to have similarly low surface tensions. This study investigates the potential of modified SMAs and/or SMA-phospholipid complexes, which form under physiological conditions, to supplement natural tear film surfactants. Method: SMAs were modified to provide structural variants which can form complexes under varying conditions. Infrared spectroscopy and Nuclear Magnetic Resonance were used to confirm SMA structure. Interfacial behaviour of the SMA and SMA-phospholipid complexes was studied using Langmuir trough, du Nûoy ring and pulsating bubblemethods. Factors which affect SMA-phospholipid complex formation, such as temperature and pH, were also investigated. Results: Structural manipulation of SMAs allows control over complex formation, including under physiological conditions (e.g. partial SMAesterfication allowed complexation with dimyristoylphosphatidylcholine, at pH7). The low surface tensions of the SMAs (42mN/m for static (du Nûoy ring) and 34mN/m for dynamic (Langmuir) techniques) demonstrate their surface activity at the air-aqueous interface. SMA-phospholipid complexes provide even lower surface tensions (~2 mN/m), approaching that of lung surfactant, as measured by the pulsating bubblemethod. Conclusions: Design of the molecular architecture of SMAs allows control over their surfactant properties. These SMAs could be used as novel tear films supplements, either alone to complex with native tear film phospholipids or delivered as synthetic protein-phospholipid complexes.
Resumo:
The thesis deals with the background, development and description of a mathematical stock control methodology for use within an oil and chemical blending company, where demand and replenishment lead-times are generally non-stationary. The stock control model proper relies on, as input, adaptive forecasts of demand determined for an economical forecast/replenishment period precalculated on an individual stock-item basis. The control procedure is principally that of the continuous review, reorder level type, where the reorder level and reorder quantity 'float', that is, each changes in accordance with changes in demand. Two versions of the Methodology are presented; a cost minimisation version and a service level version. Realising the importance of demand forecasts, four recognised variations of the Trigg and Leach adaptive forecasting routine are examined. A fifth variation, developed, is proposed as part of the stock control methodology. The results of testing the cost minimisation version of the Methodology with historical data, by means of a computerised simulation, are presented together with a description of the simulation used. The performance of the Methodology is in addition compared favourably to a rule-of-thumb approach considered by the Company as an interim solution for reducing stack levels. The contribution of the work to the field of scientific stock control is felt to be significant for the following reasons:- (I) The Methodology is designed specifically for use with non-stationary demand and for this reason alone appears to be unique. (2) The Methodology is unique in its approach and the cost-minimisation version is shown to work successfully with the demand data presented. (3) The Methodology and the thesis as a whole fill an important gap between complex mathematical stock control theory and practical application. A brief description of a computerised order processing/stock monitoring system, designed and implemented as a pre-requisite for the Methodology's practical operation, is presented as an appendix.
Resumo:
With the competitive challenge facing business today, the need to keep cost down and quality up is a matter of survival. One way in which wire manufacturers can meet this challenge is to possess a thorough understanding of deformation, friction and lubrication during the wire drawing process, and therefore to make good decisions regarding the selection and application of lubricants as well as the die design. Friction, lubrication and die design during wire drawing thus become the subject of this study. Although theoretical and experimental investigations have been being carried out ever since the establishment of wire drawing technology, many problems remain unsolved. It is therefore necessary to conduct further research on traditional and fundamental subjects such as the mechanics of deformation, friction, lubrication and die design in wire drawing. Drawing experiments were carried out on an existing bull-block under different cross-sectional area reductions, different speeds and different lubricants. The instrumentation to measure drawing load and drawing speed was set up and connected to the wire drawing machine, together with a data acquisition system. A die box connected to the existing die holder for using dry soap lubricant was designed and tested. The experimental results in terms of drawing stress vs percentage area reduction curves under different drawing conditions were analysed and compared. The effects on drawing stress of friction, lubrication, drawing speed and pressure die nozzle are discussed. In order to determine the flow stress of the material during deformation, tensile tests were performed on an Instron universal test machine, using the wires drawn under different area reductions. A polynomial function is used to correlate the flow stress of the material with the plastic strain, on which a general computer program has been written to find out the coefficients of the stress-strain function. The residual lubricant film on the steel wire after drawing was examined both radially and longitudinally using an SEM and optical microscope. The lubricant film on the drawn wire was clearly observed. Therefore, the micro-analysis by SEM provides a way of friction and lubrication assessment in wire drawing.
Resumo:
A novel method for tablet coating was studied where a thin polymer film was cast (pre-formed film), dried and applied as a coating hence eliminating the need for using any solvent during the actual coating process. A pre-formed film is initially heating to a temperature where it becomes flexible, a vacuum is applied and the film is then pulled around the tablet. The proposed films (gelatine or cellulose-based) were characterised in terms of their dissolution, swelling, mechanical and thermal properties prior to using them in the novel coating process; selected films were then coated onto tablets containing paracetamol or ibuprofen and the effect of the film on the subsequent dissolution was evaluated. It was found that the pre-formed films could be designed to be fast dissolving and mechanically strong to withstand the stress from the coating process. Also metoclopramide was incorporated in a gelatine film-coating formulation which was then successfully coated on paracetamol-containing core. Gelatin-based films were found to be successful in the novel coating process therefore to be suitable as finished coatings for immediate release dosage forms. Orally disintegrating dosage forms have been identified as a favourable dosage form due to the following reasons: fast onset of drug release, easy to use, not painful and possible increase of amount absorbed to systemic circulation. Selected films formulated for coating studies were also successfully formulated to contain active ingredient suitable for orally disintegrating dosage form; cellulose-based naratriptan-films were studied as orally disintegrating dosage forms of where the effect of formulation on the film properties was studied. It was found that strength of the film can affect the dissolution of the film but it may be the inclusion of specific excipients in the formulation which affect the penetration of the drug through mucosa.
Resumo:
The possible evaporation of lubricant in fluid film bearings has been investigated theoretically and by experiment using a radial flow hydrostatic bearing supplied with liquid refrigerant R114. Good correlation between measured and theoretical values was obtained using a bespoke computational fluid dynamic model in which the flow was assumed to be laminar and adiabatic. The effects of viscous dissipation and vapour generation within the fluid film are fully accounted for by applying a fourth order Runge-Kutta routine to satisfy the radial and filmwise transverse constraints of momentum, energy and mass conservation. The results indicate that the radial velocity profile remains parabolic while the flow remains in the liquid phase and that the radial rate of enthalpy generation is then constant across the film at a given radius. The results also show that evaporation will commence at a radial location determined by geometry and flow conditions and in fluid layers adjacent to the solid boundaries. Evaporation is shown to progress in the radial direction and the load carrying capacity of such a bearing is reduced significantly. Expressions for the viscosity of the liquid/vapour mixture found in the literature survey have not been tested against experimental data. A new formulation is proposed in which the suitable choice of a characteristic constant yields close representation to any of these expressions. Operating constraints imposed by the design of the experimental apparatus limited the extent of the surface over which evaporation could be obtained, and prevented clear identification of the most suitable relationship for the viscosity of the liquid/vapour mixture. The theoretical model was extended to examine the development of two phase flow in a rotating shaft face seal of uniform thickness. Previous theoretical analyses have been based on the assumption that the radial velocity profile of the flow is always parabolic, and that the tangential component of velocity varies linearly from the value at the rotating surface, to zero at the stationary surface. The computational fluid dynamic analysis shows that viscous shear and dissipation in the fluid adjacent to the rotating surface leads to developing evaporation with a consequent reduction in tangential shear forces. The tangential velocity profile is predicted to decay rapidly through the film, exhibiting a profile entirely different to that assumed by previous investigators. Progressive evaporation takes place close to the moving wall and does not occur completely at a single radial location, as has been claimed in earlier work.
Resumo:
The growing use of a variety of information systems in crisis management both by non-governmental organizations (NGOs) and emergency management agencies makes the challenges of information sharing and interoperability increasingly important. The use of semantic web technologies is a growing area and is a technology stack specifically suited to these challenges. This paper presents a review of ontologies, vocabularies and taxonomies that are useful in crisis management systems. We identify the different subject areas relevant to crisis management based on a review of the literature. The different ontologies and vocabularies available are analysed in terms of their coverage, design and usability. We also consider the use cases for which they were designed and the degree to which they follow a variety of standards. While providing comprehensive ontologies for the crisis domain is not feasible or desirable there is considerable scope to develop ontologies for the subject areas not currently covered and for the purposes of interoperability.
Resumo:
Changing demographics and in particular an increasingly ageing population, in combination with improved longevity, will have a major impact on changing the face of human diseases and likewise the demand for appropriate biomaterials. The ocular surface is a multifaceted system that combines to create a unique mucosal surface, which includes the cornea, conjunctiva, sclera and lids of the eye. Physical parameters such as the eyelids and eyelashes, combined with the numerous secretory glands that produce the complex tear film, act together to protect and maintain the cornea. Unfortunately an ageing tear film and lacrimal functional unit can lead to impairment of this magnificently orchestrated structure. No single mechanism or modification is responsible but, whatever the cause, the consequence is a reduction in tear stability. An uncompromised tear film is fundamental to a healthy ocular surface. In the face of progressively changing demographics and consequent requirements for medical intervention and medical device developments, it is important to understand what effects the ageing process has on these anterior ocular structures.
Resumo:
The successful design of polymers for contact lens applications depends on the ability to provide a balance of properties appropriate to the ocular environment. Principal relevant aspects of the anterior eye are the tear film, eyelid and cornea, which govern the requirements for surface properties, modulus and oxygen permeability, respectively. Permeability requirements and the developing view of the needs of the cornea, in terms of oxygen consumption and the particular roles of fluorine and silicon in the design of silicone hydrogels, which have proved to be the most successful family of materials for this demanding application, are discussed. The contact lens field is complicated by the fact that contact lenses are used in a range of wear modalities, the extremes of which can conveniently be classified as lenses that are disposed of at the end of a single period of daily wear and those used for 30. days of successive day-and-night periods, frequently referred to as extended or continuous wear. As silicone hydrogels developed, in the decade following their launch there has been a progressive trend in properties taking both modulus and water content closer to those of conventional hydrogels. This is particularly evident in the family of daily disposable contact lenses that have appeared since 2008.
Resumo:
Atomisation of an aqueous solution for tablet film coating is a complex process with multiple factors determining droplet formation and properties. The importance of droplet size for an efficient process and a high quality final product has been noted in the literature, with smaller droplets reported to produce smoother, more homogenous coatings whilst simultaneously avoiding the risk of damage through over-wetting of the tablet core. In this work the effect of droplet size on tablet film coat characteristics was investigated using X-ray microcomputed tomography (XμCT) and confocal laser scanning microscopy (CLSM). A quality by design approach utilising design of experiments (DOE) was used to optimise the conditions necessary for production of droplets at a small (20 μm) and large (70 μm) droplet size. Droplet size distribution was measured using real-time laser diffraction and the volume median diameter taken as a response. DOE yielded information on the relationship three critical process parameters: pump rate, atomisation pressure and coating-polymer concentration, had upon droplet size. The model generated was robust, scoring highly for model fit (R2 = 0.977), predictability (Q2 = 0.837), validity and reproducibility. Modelling confirmed that all parameters had either a linear or quadratic effect on droplet size and revealed an interaction between pump rate and atomisation pressure. Fluidised bed coating of tablet cores was performed with either small or large droplets followed by CLSM and XμCT imaging. Addition of commonly used contrast materials to the coating solution improved visualisation of the coating by XμCT, showing the coat as a discrete section of the overall tablet. Imaging provided qualitative and quantitative evidence revealing that smaller droplets formed thinner, more uniform and less porous film coats.