3 resultados para extraction procedures

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The surface nature of Acanthamoeba trophozoites and cysts was investigated with respect to cell surface charge, hydrophobicity and surface carbohydrate composition. Particulate microelectrophoresis revealed a marked negative charge for both morphological forms, though less for cyst surfaces. Hydrophobicity was determined by adhesion to n-hexadecane and indicated a relatively low hydrophobic nature of both forms, though less so for cysts. Surface carbohydrate composition was studied by the use of fluorescent lectins and flow cytometry, using a ligand-receptor approach for further in depth analysis of binding of particular lectins. These studies showed trophozoite and cyst surfaces to be rich in N-acetylglucosamine, N-acteylneuraminic acid, mannose and glucose, with the addition of N-acetylgalactosamine on cysts. The importance of such surface properties was investigated with respect to phagocytosis of polystyrene latex microspheres, of different surface types and size. Investigations into the optimum conditions of uptake of beads indicated a preference for a medium devoid of nutrients, such as saline, though temperature was not a factor. An amoebal predilection for beads of lower charge and greater hydrophobicity was demonstrated. Furthermore, a preference for the largest bead size used (2.0 m) was observed. The influence of either Con A or mannose or glucose on bead association was apparently limited. The fate of foreign DNA ingested by Acanthamoeba appeared to indicate that such DNA was destroyed, as it could not be detected following extraction procedures and PCR amplification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature on the potential use of liquid ammonia as a solvent for the extraction of aromatic hydrocarbons from mixtures with paraffins, and the application of reflux, has been reviewed. Reference is made to extractors suited to this application. A pilot scale extraction plant was designed comprising a Scm. diameter by 12Scm. high, 50 stage Rotating Disc Contactor with 2 external settlers. Provision was made for operation with, or without, reflux at a pressure of 10 bar and ambient temperature. The solvent recovery unit consisted of an evaporator, compressor and condenser in a refrigeration cycle. Two systems were selected for study, Cumene-n-Heptane-Ammonia and Toluene-Methylcyclohexane-Ammonia. Equlibrium data for the first system was determined experimentally in a specially-designed, equilibrium bomb. A technique was developed to withdraw samples under pressure for analysis by chromatography and titration. The extraction plant was commissioned with a kerosine-water system; detailed operating procedures were developed based on a Hazard and Operability Study. Experimental runs were carried out with both ternary ammonia systems. With the system Toluene-Methylcyclohexane-Ammonia the extraction plant and the solvent recovery facility, operated satisfactorily, and safely,in accordance with the operating procedures. Experimental data gave reasonable agreement with theory. Recommendations are made for further work with plant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of styrene maleic acid (SMA) co-polymers to extract and purify transmembrane proteins, whilst retaining their native bilayer environment, overcomes many of the disadvantages associated with conventional detergent based procedures. This approach has huge potential for the future of membrane protein structural and functional studies. In this investigation we have systematically tested a range of commercially available SMA polymers, varying in both the ratio of styrene to maleic acid and in total size, for the ability to extract, purify and stabilise transmembrane proteins. Three different membrane proteins (BmrA, LeuT and ZipA) which vary in size and shape were used. Our results show that several polymers can be used to extract membrane proteins comparably to conventional detergents. A styrene:maleic acid ratio of either 2:1 or 3:1, combined with a relatively small average molecular weight (7.5-10 kDa) is optimal for membrane extraction, and this appears to be independent of the protein size, shape or expression system. A subset of polymers were taken forward for purification, functional and stability tests. Following a one-step affinity purification SMA 2000 was found to be the best choice for yield, purity and function. However the other polymers offer subtle differences in size and sensitivity to divalent cations that may be useful for a variety of downstream applications.