15 resultados para epoc® blood analysis system

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis describes work undertaken in order to fulfil a need experienced in the Department of Educational Enquiry at the University of Aston in Birmingham for speech analysis facilities suitable for use in teaching and research work within the Department. The hardware and software developed during the research project provides displays of speech fundamental frequency and intensity in real time. The system is suitable for the provision of visual feedback of these parameters of a subject's speech in a learning situation, and overcomes the inadequacies of equipment currently used for this task in that it provides a clear indication of fundamental frequency contours as the subject is speaking. The thesis considers the use of such equipment in several related fields, and the approaches that have been reported to one of the major problems of speech analysis, namely pitch-period estimation. A number of different systems are described, and their suitability for the present purposes is discussed. Finally, a novel method of pitch-period estimation is developed, and a speech analysis system incorporating this method is described. Comparison is made between the results produced by this system and those produced by a conventional speech spectrograph.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes the development of a proton induced X-ray emission (PIXE) analysis system, especially designed and builtfor routine quantitative multi-elemental analysis of a large number of samples. The historical and general developments of the analytical technique and the physical processes involved are discussed. The philosophy, design, constructional details and evaluation of a versatile vacuum chamber, an automatic multi-sample changer, an on-demand beam pulsing system and ion beam current monitoring facility are described.The system calibration using thin standard foils of Si, P, S,Cl, K, Ca, Ti, V, Fe, Cu, Ga, Ge, Rb, Y and Mo was undertaken at proton beam energies of 1 to 3 MeV in steps of 0.5 MeV energy and compared with theoretical calculations. An independent calibration check using bovine liver Standard Reference Material was performed.  The minimum detectable limits have been experimentally determined at detector positions of 90° and 135° with respect to the incident beam for the above range of proton energies as a function of atomic number Z. The system has detection limits of typically 10- 7 to 10- 9 g for elements 14analysis and calculations of areal density of thin foils using Rutherford backscattering data.  Amniotic fluid samples supplied by South Sefton Health Authority were successfully analysed for their low base line elemental concentrations. In conclusion the findings of this work are discussed with suggestions for further work .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work concerns the developnent of a proton irduced X-ray emission (PIXE) analysis system and a multi-sample scattering chamber facility. The characteristics of the beam pulsing system and its counting rate capabilities were evaluated by observing the ion-induced X-ray emission from pure thick copper targets, with and without beam pulsing operation. The characteristic X-rays were detected with a high resolution Si(Li) detector coupled to a rrulti-channel analyser. The removal of the pile-up continuum by the use of the on-demand beam pulsing is clearly demonstrated in this work. This new on-demand pu1sirg system with its counting rate capability of 25, 18 and 10 kPPS corresponding to 2, 4 am 8 usec main amplifier time constant respectively enables thick targets to be analysed more readily. Reproducibility tests of the on-demard beam pulsing system operation were checked by repeated measurements of the system throughput curves, with and without beam pulsing. The reproducibility of the analysis performed using this system was also checked by repeated measurements of the intensity ratios from a number of standard binary alloys during the experimental work. A computer programme has been developed to evaluate the calculations of the X-ray yields from thick targets bornbarded by protons, taking into account the secondary X-ray yield production due to characteristic X-ray fluorescence from an element energetically higher than the absorption edge energy of the other element present in the target. This effect was studied on metallic binary alloys such as Fe/Ni and Cr/Fe. The quantitative analysis of Fe/Ni and Cr/Fe alloy samples to determine their elemental composition taking into account the enhancement has been demonstrated in this work. Furthermore, the usefulness of the Rutherford backscattering (R.B.S.) technique to obtain the depth profiles of the elements in the upper micron of the sample is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The density of axons in the optic nerve, olfactory tract and corpus callosum was quantified in non-demented elderly subjects and in Alzheimer’s disease (AD) using an image analysis system. In each fibre tract, there was significant reduction in the density of axons in AD compared with non-demented subjects, the greatest reductions being observed in the olfactory tract and corpus callosum. Axonal loss in the optic nerve and olfactory tract was mainly of axons with smaller myelinated cross-sectional areas. In the corpus callosum, a reduction in the number of ‘thin’ and ‘thick’ fibres was observed in AD, but there was a proportionally greater loss of the ‘thick’ fibres. The data suggest significant degeneration of white matter fibre tracts in AD involving the smaller axons in the two sensory nerves and both large and small axons in the corpus callosum. Loss of axons in AD could reflect an associated white matter disorder and/or be secondary to neuronal degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To assess the relationship between macular pigment optical density (MPOD) and blood markers for antioxidant defense in otherwise healthy volunteers. Methods. Forty-seven healthy volunteers were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. The level of MPOD was measured using heterochromatic flicker photometry. Systemic blood pressure (BP) parameters, heart rate (HR), body mass index (BMI), and plasma levels of total, HDL, and LDL cholesterol and triglycerides (TGs) were also determined. Results. A simple correlation model revealed that the level of MPOD correlated significantly and positively with both GSH (P < 0.001) and t-GSH (P < 0.001) levels but not with those of GSSG (P > 0.05). Age, sex, systemic BP parameters, HR, BMI, and plasma levels of cholesterol and TGs did not have any influence on either MPOD or glutathione levels (all P > 0.05). In addition, a forward stepwise multiple regression analysis showed MPOD to have a significantly and independent correlation with GSH levels (ß = 0.63; P < 0.001). Conclusions. In otherwise healthy older individuals, there is a positive correlation between local and systemic antioxidant defense mechanisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. Using an image analysis system to determine whether there is loss of axons in the olfactory tract (OT) in Alzheimer’s disease (AD). Design. A retrospective neuropathological study. Patients Nine control patients and eight clinically and pathologically verified AD cases. Measurements and Results. There was a reduction in axon density in AD compared with control subjects in the central and peripheral regions of the tract. Axonal loss was mainly of axons with smaller (<2.99 µm2) myelinated cross-sectional areas. Conclusions. The data suggest significant degeneration of axons within the OT involving the smaller sized axons. Loss of axons in the OT is likely to be secondary to pathological changes originating within the parahippocampal gyrus rather than to a pathogen spreading into the brain via the olfactory pathways.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To study the density and cross-sectional area of axons in the optic nerve in elderly control subjects and in cases of Alzheimer's disease (AD) using an image analysis system. Methods: Sections of optic nerves from control and AD patients were stained with toluidine blue to reveal axon profiles. Results: The density of axons was reduced in both the center and peripheral portions of the optic nerve in AD compared with control patients. Analysis of axons with different cross-sectional areas suggested a specific loss of the smaller sized axons in AD, i.e., those with areas less that 1.99 μm2. An analysis of axons >11 μm2 in cross-sectional area suggested no specific loss of the larger axons in this group of patients. Conclusions: The data suggest that image analysis provides an accurate and reproducible method of quantifying axons in the optic nerve. In addition, the data suggest that axons are lost throughout the optic nerve with a specific loss of the smaller-sized axons. Loss of the smaller axons may explain the deficits in color vision observed in a significant proportion of patients with AD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To investigate in parallel the systemic glutathione levels of patients suffering from primary open angle glaucoma (POAG) or normal tension glaucoma (NTG) with comparable functional loss. METHODS. Thirty-four POAG patients, 30 NTG patients, and 53 controls were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. Systemic blood pressure (BP) and ocular perfusion pressure (OPP) parameters were also determined. RESULTS. Independent of age, POAG and NTG patients demonstrated significantly lower GSH and t-GSH levels than age-matched controls (P < 0.001). Additionally, a lower redox index was found, but in POAG patients only, in comparison to both NTG and control groups (P = 0.020). GSSG levels were, however, similar between all study groups (P > 0.05). CONCLUSIONS. This study demonstrates, for the first time, that both POAG and NTG patients exhibit lower GSH and t-GSH levels than age-matched controls, indicating a similar general compromise of the antioxidant defense systems may exist in both conditions. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aircraft manufacturing industries are looking for solutions in order to increase their productivity. One of the solutions is to apply the metrology systems during the production and assembly processes. Metrology Process Model (MPM) (Maropoulos et al, 2007) has been introduced which emphasises metrology applications with assembly planning, manufacturing processes and product designing. Measurability analysis is part of the MPM and the aim of this analysis is to check the feasibility for measuring the designed large scale components. Measurability Analysis has been integrated in order to provide an efficient matching system. Metrology database is structured by developing the Metrology Classification Model. Furthermore, the feature-based selection model is also explained. By combining two classification models, a novel approach and selection processes for integrated measurability analysis system (MAS) are introduced and such integrated MAS could provide much more meaningful matching results for the operators. © Springer-Verlag Berlin Heidelberg 2010.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To assess the level of plasma glutathione in patients with untreated primary open-angle glaucoma. METHODS. Twenty-one patients with newly diagnosed primary open-angle glaucoma and 34 age- and gender-matched control subjects were subjected to a blood analysis to detect the level of circulating glutathione in its reduced and oxidized forms. The effect of age, gender, and systemic blood pressure on circulating glutathione levels was also analyzed. RESULTS. Age had a negative effect on the level of both reduced and total glutathione (P = 0.002, r = -0.52 and P = 0.002, r = -0.52, respectively) in control subjects but not in patients with glaucoma (P > 0.05, r = 0.27, and P > 0.05, r = 0.22, respectively). In the control group, men demonstrated higher levels of both reduced and total glutathione than did women (P = 0.024 and P = 0.032, respectively). After correction for age and gender influences on blood glutathione levels, patients with glaucoma exhibited significantly lower levels of reduced and total glutathione than did control subjects (P = 0.010, F = 7.24 and P = 0.006, F = 8.38, respectively). No differences between study groups were observed in either oxidized glutathione levels or redox index (P > 0.05, F = 0.50; and P > 0.05, F = 0.30, respectively). CONCLUSIONS. Patients with glaucoma exhibit low levels of circulating glutathione, suggesting a general compromise of the antioxidative defense. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to design, construct, commission and operate a laboratory scale gasifier system that could be used to investigate the parameters that influence the gasification process. The gasifier is of the open-core variety and is fabricated from 7.5 cm bore quartz glass tubing. Gas cleaning is by a centrifugal contacting scrubber, with the product gas being flared. The system employs an on-line dedicated gas analysis system, monitoring the levels of H2, CO, CO2 and CH4 in the product gas. The gas composition data, as well as the gas flowrate, temperatures throughout the system and pressure data is recorded using a BBC microcomputer based data-logging system. Ten runs have been performed using the system of which six were predominantly commissioning runs. The main emphasis in the commissioning runs was placed on the gas clean-up, the product gas cleaning and the reactor bed temperature measurement. The reaction was observed to occur in a narrow band, of about 3 to 5 particle diameters thick. Initially the fuel was pyrolysed, with the volatiles produced being combusted and providing the energy to drive the process, and then the char product was gasified by reaction with the pyrolysis gases. Normally, the gasifier is operated with reaction zone supported on a bed of char, although it has been operated for short periods without a char bed. At steady state the depth of char remains constant, but by adjusting the air inlet rate it has been shown that the depth of char can be increased or decreased. It has been shown that increasing the depth of the char bed effects some improvement in the product gas quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Variation in lichen growth rates poses a significant challenge for the application of direct lichenometry, i.e. the construction of lichen dating curves from direct measurement of growth rates. To examine the magnitude and possible causes of within-site growth variation, radial growth rates (RaGRs) of thalli of the fast-growing foliose lichen Melanelia fuliginosa ssp. fuliginosa (Fr. ex Duby) Essl. and the slow-growing crustose lichen Rhizocarpon geographicum (L.) DC. were studied on two S-facing slate rock surfaces in north Wales, UK using digital photography and an image analysis system (Image-J). RaGRs of M. fuliginosa ssp. fuliginosa varied from 0.44 to 2.63 mmyr-1 and R. geographicum from 0.10 to 1.50 mmyr-1.5. Analysis of variance suggested no significant variation in RaGRs with vertical or horizontal location on the rock, thallus diameter, aspect, slope, light intensity, rock porosity, rock surface texture, distance to nearest lichen neighbour or distance to vegetation on the rock surface. The frequency distribution of RaGR did not deviate from a normal distribution. It was concluded that despite considerable growth rate variation in both species studied, growth curves could be constructed with sufficient precision to be useful for direct lichenometry. © 2014 Swedish Society for Anthropology and Geography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To disentangle the effects of physician gender and patient-centered communication style on patients' oral engagement in depression care. Methods: Physician gender, physician race and communication style (high patient-centered (HPC) and low patient-centered (LPC)) were manipulated and presented as videotaped actors within a computer simulated medical visit to assess effects on analogue patient (AP) verbal responsiveness and care ratings. 307 APs (56% female; 70% African American) were randomly assigned to conditions and instructed to verbally respond to depression-related questions and indicate willingness to continue care. Disclosures were coded using Roter Interaction Analysis System (RIAS). Results: Both male and female APs talked more overall and conveyed more psychosocial and emotional talk to HPC gender discordant doctors (all p <.05). APs were more willing to continue treatment with gender-discordant HPC physicians (p <.05). No effects were evident in the LPC condition. Conclusions: Findings highlight a role for physician gender when considering active patient engagement in patient-centered depression care. This pattern suggests that there may be largely under-appreciated and consequential effects associated with patient expectations in regard to physician gender that these differ by patient gender. Practice implications: High patient-centeredness increases active patient engagement in depression care especially in gender discordant dyads. © 2014.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The exact nature of the relationship between Alzheimer’s disease (AD) and primary open angle glaucoma (POAG) is still the subject of debate. One factor attributed to the aetiology of both conditions is vascular dysfunction. This study aimed to investigate the similarities and differences in retinal microvascular function between mild AD patients, early stage POAG patients and healthy controls Methods: Retinal vessel reactivity to flickering light was assessed in 10 AD, 19 POAG and 22 healthy age matched control patients by means of dynamic retinal vessel analysis (DVA, IMEDOS, GmbH, Jena, Germany) according to an established protocol. All patients additionally underwent BP measurements and blood analysis for glucose and lipid metabolism markers Results: AD and POAG patients demonstrated comparable alterations in retinal artery reactivity, in the form of an increased arterial reaction time (RT) to flicker light on the final flicker cycle (p=0.014), which was not replicated in the healthy age and cardiovascular risk matched controls (p>0.05). Furthermore, the sequential changes in RT on progressing from flicker one to flicker three were found to differ between healthy controls and the two disease groups (p=0.001) Conclusions: AD and POAG patients demonstrate comparable signs of vascular dysfunction in their retinal arteries at the early stages of their disease process. These comparable signs may reflect similarities in the pathophysiological processes that occur in the development of both conditions

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP; and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60° included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, ?. The test was repeated for three backing conditions: (i) non-backed; (ii) steel-cupped; and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0° cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s2 shock excitation on the impeller. Although the 12 magnet 0° (?) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.