11 resultados para end-state comfort
em Aston University Research Archive
Resumo:
To ensure state synchronization of signalling operations, many signaling protocol designs choose to establish “soft” state that expires if it is not refreshed. The approaches of refreshing state in multi-hop signaling system can be classified as either end-to-end (E2E) or hop-by-hop (HbH). Although both state refresh approaches have been widely used in practical signaling protocols, the design tradeoffs between state synchronization and signaling cost have not yet been fully investigated. In this paper, we investigate this issue from the perspectives of state refresh and state removal. We propose simple but effective Markov chain models for both approaches and obtain closed-form solutions which depict the state refresh performance in terms of state consistency and refresh message rate, as well as the state removal performance in terms of state removal delay. Simulations verify the analytical models. It is observed that the HbH approach yields much better state synchronization at the cost of higher signaling cost than the E2E approach. While the state refresh performance can be improved by increasing the values of state refresh and timeout timers, the state removal delay increases largely for both E2E and HbH approaches. The analysis here shed lights on the design of signaling protocols and the configuration of the timers to adapt to changing network conditions.
Resumo:
The concept of soft state (i.e., the state that will expire unless been refreshed) has been widely used in the design of network signaling protocols. The approaches of refreshing state in multi-hop networks can be classified to end-to-end (E2E) and hop-by-hop (HbH) refreshes. In this article we propose an effective Markov chain based analytical model for both E2E and HbH refresh approaches. Simulations verify the analytical models, which can be used to study the impacts of link characteristics on the performance (e.g., state synchronization and message overhead), as a guide on configuration and optimization of soft state signaling protocols. © 2009 IEEE.
Resumo:
Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
Resumo:
Purpose: To examine the objective clinical performance of ‘comfort-enhanced’ daily disposable contact lenses over a 16-h day. Methods: Four contact lenses (Hilafilcon B, Etafilcon A Plus, Nelfilcon A and Nelfilcon A Plus) were evaluated in an investigator masked, open label trial at the end of a week’s bilateral wear. Pre-lens noninvasive tear break-up time (PL-NITBUT), tear prism height, bulbar hyperaemia and ocular surface temperature (OST) were measured with the lens in situ at 8, 12 and 16 h of wear. Results: There was no difference between how many hours the lenses types were worn each day (F = 0.90, p = 0.44). The PL-NITBUT decreased with the duration of daily lens wear (F = 32.0, p < 0.001) and was more stable with Nelfilcon A Plus (F = 6.00, p = 0.002) than with the other lenses evaluated. Bulbar blood vessels increased in coverage (F = 11.5, p < 0.001) but not overall redness (F = 0.0, p = 0.99) with the duration of daily lens wear, but there was no difference between the lenses (p > 0.05). The tear prism height decreased with the duration of daily wear (F = 27.0, p < 0.001) and differed between lenses (F = 2.9, p = 0.04). The OST decreased with the duration of lens wear (F = 119.7, p < 0.001) and was reduced by daily disposable lens wear (F = 7.88, p < 0.001), but did not differ between lenses (F = 0.88, p = 0.45). Conclusions: Objective measures of tear film indicated a difference between the lenses evaluated for PLNITBUT and tear prism height, but not for wearing time or bulbar conjunctival hyperaemia. Therefore clinical benefits of daily disposable ‘comfort enhancing’ contact lenses can be measured, but challenges remain in producing contact lenses that do not compromise anterior eye physiology over the whole day. 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
This article describes a 6-yr study of the radial growth rates (RGR, mm yr-1) of Rhizocarpon section Rhizocarpon thalli on a talus slope at Snoqualmie Pass in the Cascade Range, Washington State, United States (47°27'N; 121°26'W). At the end of the growth period, 32 of a total of 39 thalli had exhibited a positive RGR, and 7 of a total of 39 thalli showed no measurable growth. Mean RGR of all thalli was 0.07 mm yr-1 (range, 0-0.19 mm, SD = 0.06). Analysis of variance suggested no significant variation in RGR in successive growth periods, but significant differences were present both within and between thalli. The slope of a boulder facet did not influence RGR, but growth was affected by aspect, the least growth being observed on north-northwest facets. A plot of RGR against thallus diameter revealed a wide scatter of data points with little evidence for a significant change in growth with thallus size. Hence, the study showed that the RGR of Rhizocarpon thalli at Snoqualmie is extremely slow and highly variable and significantly less than estimates based on lichenometry. To determine the growth curve of a yellow-green Rhizocarpon by direct measurement at such a site would require a large sample of thalli and careful standardization of the species studied, the aspect conditions under which the thalli were measured, and the initial hypothallus width of the thalli. © 2005 Regents of the University of Colorado.
Resumo:
Nanotechnologies have been called the "Next Industrial Revolution." At the same time, scientists are raising concerns about the potential health and environmental risks related to the nano-sized materials used in nanotechnologies. Analyses suggest that current U.S. federal regulatory structures are not likely to adequately address these risks in a proactive manner. Given these trends, the premise of this paper is that state and local-level agencies will likely deal with many "end-of-pipe" issues as nanomaterials enter environmental media without prior toxicity testing, federal standards, or emissions controls. In this paper we (1) briefly describe potential environmental risks and benefits related to emerging nanotechnologies; (2) outline the capacities of the Toxic Substances Control Act, the Clean Air Act, the Clean Water Act, and the Resources Conservation and Recovery Act to address potential nanotechnology risks, and how risk data gaps challenge these regulations; (3) outline some of the key data gaps that challenge state-level regulatory capacities to address nanotechnologies' potential risks, using Wisconsin as a case study; and (4) discuss advantages and disadvantages of state versus federal approaches to nanotechnology risk regulation. In summary, we suggest some ways government agencies can be better prepared to address nanotechnology risk knowledge gaps and risk management.
Resumo:
The role of the production system as a key determinant of competitive performance of business operations- has long been the subject of industrial organization research, even predating the .explicit conceptua1isation of manufacturing, strategy in the literature. Particular emergent production issues such as the globalisation of production, global supply chain management, management of integrated manufacturing and a growing e~busjness environment are expected to critically influence the overall competitive performance and therefore the strategic success of the organization. More than ever, there is a critical need to configure and improve production system and operations competence in a strategic way so as to contribute to the long-term competitiveness of the organization. In order to operate competitively and profitably, manufacturing companies, no matter how well managed, all need a long-term 'strategic direction' for the development of operations competence in order to consistently produce more market value with less cost towards a leadership position. As to the long-term competitiveness, it is more important to establish a dynamic 'strategic perspective' for continuous operational improvements in pursuit of this direction, as well as ongoing reviews of the direction in relation to the overall operating context. However, it also clear that the 'existing paradigm of manufacturing strategy development' is incapable of adequately responding to the increasing complexities and variations of contemporary business operations. This has been factually reflected as many manufacturing companies are finding that methodologies advocated in the existing paradigm for developing manufacturing strategy have very limited scale and scope for contextual contingency in empirical application. More importantly, there has also emerged a deficiency in the multidimensional and integrative profile from a theoretical perspective when operationalising the underlying concept of strategic manufacturing management established in the literature. The point of departure for this study was a recognition of such contextual and unitary limitations in the existing paradigm of manufacturing strategy development when applied to contemporary industrial organizations in general, and Chinese State Owned Enterprises (SOEs) in particular. As China gradually becomes integrated into the world economy, the relevance of Western management theory and its paradigm becomes a practical matter as much as a theoretical issue. Since China markedly differs from Western countries in terms of culture, society, and political and economic systems, it presents promising grounds to test and refine existing management theories and paradigms with greater contextual contingency and wider theoretical perspective. Under China's ongoing programmes of SOE reform, there has been an increased recognition that strategy development is the very essence of the management task for managers of manufacturing companies in the same way as it is for their counterparts in Western economies. However, the Western paradigm often displays a rather naive and unitary perspective of the nature of strategic management decision-making, one which largely overlooks context-embedded factors and social/political influences on the development of manufacturing strategy. This thesis studies the successful experiences of developing manufacturing strategy from five high-performing large-scale SOEs within China’s petrochemical industry. China’s petrochemical industry constitutes a basic heavy industrial sector, which has always been a strategic focus for reform and development by the Chinese government. Using a confirmation approach, the study has focused on exploring and conceptualising the empirical paradigm of manufacturing strategy development practiced by management. That is examining the ‘empirical specifics’ and surfacing the ‘managerial perceptions’ of content configuration, context of consideration, and process organization for developing a manufacturing strategy during the practice. The research investigation adopts a qualitative exploratory case study methodology with a semi-structural front-end research design. Data collection follows a longitudinal and multiple-case design and triangulates case evidence from sources including qualitative interviews, direct observation, and a search of documentations and archival records. Data analysis follows an investigative progression from a within-case preliminary interpretation of facts to a cross-case search for patterns through theoretical comparison and analytical generalization. The underlying conceptions in both the literature of manufacturing strategy and related studies in business strategy were used to develop theoretical framework and analytical templates applied during data collection and analysis. The thesis makes both empirical and theoretical contributions to our understanding of 'contemporary management paradigm of manufacturing strategy development'. First, it provides a valuable contextual contingency of the 'subject' using the business setting of China's SOEs in petrochemical industry. This has been unpacked into empirical configurations developed for its context of consideration, its content and process respectively. Of special note, a lean paradigm of business operations and production management discovered at case companies has significant implications as an emerging alternative for high-volume capital intensive state manufacturing in China. Second, it provides a multidimensional and integrative theoretical profile of the 'subject' based upon managerial perspectives conceptualised at case companies when operationalising manufacturing strategy. This has been unpacked into conceptual frameworks developed for its context of consideration, its content constructs, and its process patterns respectively. Notably, a synergies perspective towards the operating context, competitive priorities and competence development of business operations and production management has significant implications for implementing a lean manufacturing paradigm. As a whole, in so doing, the thesis established a theoretical platform for future refinement and development of context-specific methodologies for developing manufacturing strategy.
Resumo:
Gram-positive microorganisms, specifically coagulase-negative staphylococci are the most common species recovered from clinical culture specimens of patients with end-stage renal disease. The propensity of coagulase-negative staphylococci (CNS) to cause infection in this patient group has been widely debated. However, it is still unclear how this usually avirulent commensal microorganism produces infection that contributes to high rates of morbidity and mortality in patients with end-stage renal disease. The aim of this thesis was to investigate the rate, geographical distribution, molecular and phenotypic mechanisms of Gram-positive microorganisms associated with infection in renal dialysis patients. In addition, it sought to assess the value of early serological diagnosis of dialysis catheter-associated infection and the effect of antimicrobial treatment regimens on the faecal carriage of enteric microorganisms. In this study, the incidence of haemodialysis catheter-associated infection was established with the Meditrend audit tool. This tool was used to assess the infection outcomes of catheter insertion and management procedures until the catheter was explanted. Introduction of a catheter management protocol decreased the incidence of catheter-related infection. Staphylococcal species recovered from episodes of haemodialysis catheter-associated infection and continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis were genotyped by determination of macrorestriction profiles with pulsed-field gel electrophoresis. This highlighted horizontal transfer of microorganisms between different patients and the environment. The phenotypic characteristics of these strains were also investigated to determine characteristics that could be used as markers for dialysis catheter-associated infection. The expression of elastase, lipase and esterase by CNS was significantly associated with infection. A rapid enzyme-linked immunosorbent assay incorporating a novel staphylococcal antigen (lipid S) was used to evaluate the early detection of anti-staphylococcal immunoglobulin gamma in patient sera. The comparison of culture positive and culture negative patients demonstrated a steady state of immune activation in both groups. However anti-lipid S serum antibody titres > 1000 were found to be a predictor of infection. The effect on faecal carriage of vancomycin resistant enterococci (VRE) and Clostridium difficile toxins in patients treated with CAPD when empiric cephalosporin therapy was substituted for piperacillin/tazobactam was investigated. The introduction of piperacillin/tazobactam demonstrated a decrease in the faecal carriage of VRE.
Resumo:
Cranfield University in collaboration with The Boeing Company have set up a Centre of Excellence in IVHM on the University?s technology park. Sponsored by the East of England Development Agency (EEDA), the Centre carries out pre-competitive research and development of IVHM technologies for the benefit of industrial partners. In addition, the dedicated facilities and university staff provide an unparalleled educational environment for learning and applying IVHM technologies. Boeing is actively involved in the creation and work of the Centre through its enterprise-wide Phantom Works technology organization. This paper will describe the organisation and operation of the Centre and will illustrate its activities by describing a research project being carried out in the Centre. This project is a demonstration of an end to end IVHM system beginning with cost/benefit analysis and extending to maintenance, logistics and operations decision support.
Resumo:
The lensing effects in diode end-pumped Yb:YAG laser rods and discs are studied. Two mechanisms of refractive-index changes are taken into account, thermal and electronic (due to the difference between the excited- and ground-state Yb polarisabilities), as well as pump-induced deformation of the laser crystal. Under pulsed pumping, the electronic lensing effect prevails over the thermal one in both rods and discs. In rods pumped by a highly focused cw beam, the dioptric power of the electronic lens exceeds that of the thermal lens, whereas in discs steady-state lensing is predominantly due to the thermal mechanism. © 2009 Kvantovaya Elektronika and Turpion Ltd.
Resumo:
The year so far has been a slow start for many businesses, but at least we have not seen the collapse of as many businesses that we were seeing around two years ago. We are, however, still well and truly in the midst of a global recession. Interest rates are still at an all time low, UK house prices seem to be showing little signs of increase (except in London where everyone still seems to want to live!) and for the ardent shopper there are bargains to be had everywhere. It seems strange that prices on the high street do not seem to have increased in over ten years. Mobile phones, DVD players even furniture seems to be cheaper than they used to be. Whist much of this is down to cheaper manufacturing and the rest could probably be explained by competition within the market place. Does this mean that quality suffered too? Now that we live in a world when if a television is not working it is thrown away and replaced. There was a time when you would take it to some odd looking man that your father would know who could fix it for you. (I remember our local television fix-it man, with his thick rimmed bifocal spectacles and a poor comb-over; he had cardboard boxes full of resistors and electrical wires on the floor of his front room that smelt of soldering irons!) Is this consumerism at an extreme or has this move to disposability made us a better society? Before you think these are just ramblings there is a point to this. According to latest global figures of contact lens sales the vast majority of contact lenses fitted around the world are daily, fortnightly or monthly disposable hydrogel lenses. Certainly in the UK over 90% of lenses are disposable (with daily disposables being the most popular, having a market share of over 50%). This begs the question – is this a good thing? Maybe more importantly, do our patients benefit? I think it is worth reminding ourselves why we went down the disposability route with contact lenses in the first place, and unlike electrical goods it was not just so we did not have to take them for repair! There are the obvious advantages of overcoming problems of breakage and tearing of lenses and the lens deterioration with age. The lenses are less likely to be contaminated and the disinfection is either easier or not required at all (in the case of daily disposable lenses). Probably the landmark paper in the field was the work more commonly known as the ‘Gothenburg Study’. The paper, entitled ‘Strategies for minimizing the Ocular Effects of Extended Contact Lens Wear’ published in the American Journal of Optometry in 1987 (volume 64, pages 781-789) by Holden, B.A., Swarbrick, H.A., Sweeney, D.F., Ho, A., Efron, N., Vannas, A., Nilsson, K.T. They suggested that contact lens induced ocular effects were minimised by: •More frequently removed contact lenses •More regularly replaced contact lenses •A lens that was more mobile on the eye (to allow better removal of debris) •Better flow of oxygen through the lens All of these issues seem to be solved with disposability, except the oxygen issue which has been solved with the advent of silicone hydrogel materials. Newer issues have arisen and most can be solved in practice by the eye care practitioner. The emphasis now seems to be on making lenses more comfortable. The problems of contact lens related dry eyes symptoms seem to be ever present and maybe this would explain why in the UK we have a pretty constant contact lens wearing population of just over three million but every year we have over a million dropouts! That means we must be attracting a million new wearers every year (well done to the marketing departments!) but we are also losing a million wearers every year. We certainly are not losing them all to the refractive surgery clinics. We know that almost anyone can now wear a contact lens and we know that some lenses will solve problems of sharper vision, some will aid comfort, and some will be useful for patients with dry eyes. So if we still have so many dropouts then we must be doing something wrong! I think the take home message has to be ‘must try harder’! I must end with an apology for two errors in my editorial of issue 1 earlier this year. Firstly there was a typo in the first sentence; I meant to state that it was 40 years not 30 years since the first commercial soft lens was available in the UK. The second error was one that I was unaware of until colleagues Geoff Wilson (Birmingham, UK) and Tim Bowden (London, UK) wrote to me to explain that soft lenses were actually available in the UK before 1971 (please see their ‘Letters to the Editor’ in this issue). I am grateful to both of them for correcting the mistake.