9 resultados para electrocardiogram

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been much recent research into extracting useful diagnostic features from the electrocardiogram with numerous studies claiming impressive results. However, the robustness and consistency of the methods employed in these studies is rarely, if ever, mentioned. Hence, we propose two new methods; a biologically motivated time series derived from consecutive P-wave durations, and a mathematically motivated regularity measure. We investigate the robustness of these two methods when compared with current corresponding methods. We find that the new time series performs admirably as a compliment to the current method and the new regularity measure consistently outperforms the current measure in numerous tests on real and synthetic data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of electrocardiogram as biometric has raised attention in the last decade and a wide variety of ECG features were explored to verify the feasibility of such a signal. In this work the authors aim to describe a simple template based approach to the electrocardiographic biometric identification using the morphology of individual's heartbeat. The developed algorithm was tested on different recordings made available in the Physionet public database Fantasia: two different sets of heartbeats were extracted from individual recordings one was used for the template building while the second for the tests. The performances of the algorithm are encouraging with a true acceptance rate of 99.4%, however, the procedure needs to be tested on different recordings of the same individual, or during the course of a whole day or physical activity. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: During last decade the use of ECG recordings in biometric recognition studies has increased. ECG characteristics made it suitable for subject identification: it is unique, present in all living individuals, and hard to forge. However, in spite of the great number of approaches found in literature, no agreement exists on the most appropriate methodology. This study aimed at providing a survey of the techniques used so far in ECG-based human identification. Specifically, a pattern recognition perspective is here proposed providing a unifying framework to appreciate previous studies and, hopefully, guide future research. Methods: We searched for papers on the subject from the earliest available date using relevant electronic databases (Medline, IEEEXplore, Scopus, and Web of Knowledge). The following terms were used in different combinations: electrocardiogram, ECG, human identification, biometric, authentication and individual variability. The electronic sources were last searched on 1st March 2015. In our selection we included published research on peer-reviewed journals, books chapters and conferences proceedings. The search was performed for English language documents. Results: 100 pertinent papers were found. Number of subjects involved in the journal studies ranges from 10 to 502, age from 16 to 86, male and female subjects are generally present. Number of analysed leads varies as well as the recording conditions. Identification performance differs widely as well as verification rate. Many studies refer to publicly available databases (Physionet ECG databases repository) while others rely on proprietary recordings making difficult them to compare. As a measure of overall accuracy we computed a weighted average of the identification rate and equal error rate in authentication scenarios. Identification rate resulted equal to 94.95 % while the equal error rate equal to 0.92 %. Conclusions: Biometric recognition is a mature field of research. Nevertheless, the use of physiological signals features, such as the ECG traits, needs further improvements. ECG features have the potential to be used in daily activities such as access control and patient handling as well as in wearable electronics applications. However, some barriers still limit its growth. Further analysis should be addressed on the use of single lead recordings and the study of features which are not dependent on the recording sites (e.g. fingers, hand palms). Moreover, it is expected that new techniques will be developed using fiducials and non-fiducial based features in order to catch the best of both approaches. ECG recognition in pathological subjects is also worth of additional investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Terrestrial Trunked Radio (TETRA) is a telecommunications system widely used by police and emergency services around the world. The Stewart Report on mobile telephony and health raised questions about possible health effects associated with TETRA signals. This study investigates possible effects of TETRA signals on the electroencephalogram and electrocardiogram in human volunteers. METHODS: Blinded randomized provocation study with a standardized TETRA signal or sham exposure. In the first of two experiments, police officers had a TETRA set placed first against the left temple and then the upper-left quadrant of the chest and the electroencephalogram was recorded during rest and active cognitive processing. In the second experiment, volunteers were subject to chest exposure of TETRA whilst their electroencephalogram and heart rate variability derived from the electrocardiogram were recorded. RESULTS: In the first experiment, we found that exposure to TETRA had consistent neurophysiological effects on the electroencephalogram, but only during chest exposure, in a pattern suggestive of vagal nerve stimulation. In the second experiment, we observed changes in heart rate variability during exposure to TETRA but the electroencephalogram effects were not replicated. CONCLUSIONS: Observed effects of exposure to TETRA signals on the electroencephalogram (first experiment) and electrocardiogram are consistent with vagal nerve stimulation in the chest by TETRA. However given the small effect on heart rate variability and the lack of consistency on the electroencephalogram, it seems unlikely that this will have a significant impact on health. Long-term monitoring of the health of the police force in relation to TETRA use is on-going.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper is twofold: first, we compute quality-adjusted measures of productivity change for the three most important diagnostic technologies (i.e., the Computerised Tomography Scan, Electrocardiogram and Echocardiogram) in the major Portuguese hospitals. We use the Malmquist–Luenberger index, which allows to measure productivity growth while controlling for the quality of the production. Second, using non-parametric tests, we analyse whether the implementation of the Prospective Payment System may have had a positive impact on the movements of productivity over time. The results show that the PPS has helped hospitals to use these tools more efficiently and to improve their effectiveness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the presence of silent cardiac ischaemic episodes and the status of autonomic function in consecutive, newly diagnosed and untreated primary open-angle glaucoma patients. Methods: Twenty-four consecutively diagnosed glaucoma patients and 22 age-matched controls were subjected to ambulatory 24-h blood pressure (BP) and electrocardiogram (ECG) monitoring by using Cardiotens-01 (Meditech Ltd). Based on the ECG recordings, heart rate variability (HRV) frequency domain parameters [low-frequency (LF), high-frequency (HF) and LF/HF ratio] were calculated and analysed in the two study groups. Results: Glaucoma patients demonstrated higher LF and LF/HF values than normal subjects for both the active period (p = 0.020 and 0.029) and the passive period (p = 0.044 and 0.049 respectively). HRV parameters were similar in patients and controls suffering from silent cardiac ischaemia (p > 0.05); however, glaucoma patients with normal ECG demonstrated higher LF and LF/HF values during the active period of the 24-h measurement period than control subjects characterized by the same cardiac activity (p = 0.010 and 0.021 respectively). Conclusion: Independent of a history and/or clinical signs of cardiovascular disease, glaucoma patients exhibit abnormal autonomic function. © 2007 The Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background - Several antipsychotic agents are known to prolong the QT interval in a dose dependent manner. Corrected QT interval (QTc) exceeding a threshold value of 450 ms may be associated with an increased risk of life threatening arrhythmias. Antipsychotic agents are often given in combination with other psychotropic drugs, such as antidepressants, that may also contribute to QT prolongation. This observational study compares the effects observed on QT interval between antipsychotic monotherapy and psychoactive polytherapy, which included an additional antidepressant or lithium treatment. Method - We examined two groups of hospitalized women with Schizophrenia, Bipolar Disorder and Schizoaffective Disorder in a naturalistic setting. Group 1 was composed of nineteen hospitalized women treated with antipsychotic monotherapy (either haloperidol, olanzapine, risperidone or clozapine) and Group 2 was composed of nineteen hospitalized women treated with an antipsychotic (either haloperidol, olanzapine, risperidone or quetiapine) with an additional antidepressant (citalopram, escitalopram, sertraline, paroxetine, fluvoxamine, mirtazapine, venlafaxine or clomipramine) or lithium. An Electrocardiogram (ECG) was carried out before the beginning of the treatment for both groups and at a second time after four days of therapy at full dosage, when blood was also drawn for determination of serum levels of the antipsychotic. Statistical analysis included repeated measures ANOVA, Fisher Exact Test and Indipendent T Test. Results - Mean QTc intervals significantly increased in Group 2 (24 ± 21 ms) however this was not the case in Group 1 (-1 ± 30 ms) (Repeated measures ANOVA p < 0,01). Furthermore we found a significant difference in the number of patients who exceeded the threshold of borderline QTc interval value (450 ms) between the two groups, with seven patients in Group 2 (38%) compared to one patient in Group 1 (7%) (Fisher Exact Text, p < 0,05). Conclusions - No significant prolongation of the QT interval was found following monotherapy with an antipsychotic agent, while combination of these drugs with antidepressants caused a significant QT prolongation. Careful monitoring of the QT interval is suggested in patients taking a combined treatment of antipsychotic and antidepressant agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanical physiological pulsations are movements of a body surface incited by the movements of muscles in organs inside the body. Here we demonstrate the use of long-period grating sensors in the detection of cardio-vascular pulsations (CVP), in particular apex and carotid pulsations. To calibrate the sensors, we use a mechanical tool designed specifically to measure the sensor response to a localized perturbation at different grating curvatures as working points. From the data we infer the amplitude of the CVP. Together with the electrophysiological signals, the CVP signals obtained from the sensors can provide significant information on heart function which is inaccessible to the electrocardiogram. The low cost and easy handling of the fibre sensors increase their prospects to become the sensors of choice for novel diagnostic devices. © 2013 The Royal Swedish Academy of Sciences.