5 resultados para elderly care regimes

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of FOCUS, which stands for Frailty Management Optimization through EIPAHA Commitments and Utilization of Stakeholders’ Input, is to reduce the burden of frailty in Europe. The partners are working on advancing knowledge of frailty detection, assessment, and management, including biological, clinical, cognitive and psychosocial markers, in order to change the paradigm of frailty care from acute intervention to prevention. FOCUS partners are working on ways to integrate the best available evidence from frailty-related screening tools, epidemiological and interventional studies into the care of frail people and their quality of life. Frail citizens in Italy, Poland and the UK and their caregivers are being called to express their views and their experiences with treatments and interventions aimed at improving quality of life. The FOCUS Consortium is developing pathways to leverage the knowledge available and to put it in the service of frail citizens. In order to reach out to the broadest audience possible, the FOCUS Platform for Knowledge Exchange and the platform for Scaling Up are being developed with the collaboration of stakeholders. The FOCUS project is a development of the work being done by the European Innovation Partnership on Active and Healthy Ageing (EIPAHA), which aims to increase the average healthy lifespan in Europe by 2020 while fostering sustainability of health/social care systems and innovation in Europe. The knowledge and tools developed by the FOCUS project, with input from stakeholders, will be deployed to all EIPAHA participants dealing with frail older citizens to support activities and optimize performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Widespread use of automated sensitive assays for thyroid hormones and thyroid-stimulating hormone (TSH) has increased identification of mild thyroid dysfunction, especially in elderly patients. The clinical significance of this dysfunction, however, remains uncertain, and associations with cognitive impairment, depression, and anxiety are unconfirmed. Objective: To determine the association between mild thyroid dysfunction and cognition, depression, and anxiety in elderly persons. Design: Cross-sectional study. Associations were explored through mixed-model analyses. Setting: Primary care practices in central England. Patients: 5865 patients 65 years of age or older with no known thyroid disease who were recruited from primary care registers. Measurements: Serum TSH and free thyroxine (T4) were measured. Depression and anxiety were assessed by using the Hospital Anxiety and Depression Scale (HADS), and cognitive functioning was established by using the Middlesex Elderly Assessment of Mental State and the Folstein Mini-Mental State Examination. Comorbid conditions, medication use, and sociodemographic profiles were recorded. Results: 295 patients met the criteria for subclinical thyroid dysfunction (127 were hyperthyroid, and 168 were hypothyroid). After confounding variables were controlled for, statistically significant associations were seen between anxiety (HADS score) and TSH level (P = 0.013) and between cognition and both TSH and free T4 levels. The magnitude of these associations lacked clinical relevance: A 50-mIU/L increase in the TSH level was associated with a 1-point reduction in the HADS anxiety score, and a 1-point increase in the Mini-Mental State Examination score was associated with an increase of 50 mIU/L in the TSH level or 25 pmol/L in the free T4 level. Limitations: Because of the low participation rate, low prevalence of subclinical thyroid dysfunction, and other unidentified recruitment biases, participants may not be representative of the elderly population. Conclusions: After the confounding effects of comorbid conditions and use of medication were controlled for, subclinical thyroid dysfunction was not associated with depression, anxiety, or cognition. © 2006 American College of Physicians.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context: Subclinical hypothyroidism (SCH) and cognitive dysfunction are both common in the elderly and have been linked. It is important to determine whether T4 replacement therapy in SCH confers cognitive benefit. Objective: Our objective was to determine whether administration of T4 replacement to achieve biochemical euthyroidism in subjects with SCH improves cognitive function. Design and Setting: We conducted a double-blind placebo-controlled randomized controlled trial in the context of United Kingdom primary care. Patients: Ninety-four subjects aged 65 yr and over (57 females, 37 males) with SCH were recruited from a population of 147 identified by screening. Intervention: T4 or placebo was given at an initial dosage of one tablet of either placebo or 25 µg T4 per day for 12 months. Thyroid function tests were performed at 8-weekly intervals with dosage adjusted in one-tablet increments to achieve TSH within the reference range for subjects in treatment arm. Fifty-two subjects received T4 (31 females, 21 males; mean age 73.5 yr, range 65–94 yr); 42 subjects received placebo (26 females, 16 males; mean age 74.2 yr, 66–84 yr). Main Outcome Measures: Mini-Mental State Examination, Middlesex Elderly Assessment of Mental State (covering orientation, learning, memory, numeracy, perception, attention, and language skills), and Trail-Making A and B were administered. Results: Eighty-two percent and 84% in the T4 group achieved euthyroidism at 6- and 12-month intervals, respectively. Cognitive function scores at baseline and 6 and 12 months were as follows: Mini-Mental State Examination T4 group, 28.26, 28.9, and 28.28, and placebo group, 28.17, 27.82, and 28.25 [not significant (NS)]; Middlesex Elderly Assessment of Mental State T4 group, 11.72, 11.67, and 11.78, and placebo group, 11.21, 11.47, and 11.44 (NS); Trail-Making A T4 group, 45.72, 47.65, and 44.52, and placebo group, 50.29, 49.00, and 46.97 (NS); and Trail-Making B T4 group, 110.57, 106.61, and 96.67, and placebo group, 131.46, 119.13, and 108.38 (NS). Linear mixed-model analysis demonstrated no significant changes in any of the measures of cognitive function over time and no between-group difference in cognitive scores at 6 and 12 months. Conclusions: This RCT provides no evidence for treating elderly subjects with SCH with T4 replacement therapy to improve cognitive function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.