3 resultados para digital capture
em Aston University Research Archive
Resumo:
This paper presents the digital imaging results of a collaborative research project working toward the generation of an on-line interactive digital image database of signs from ancient cuneiform tablets. An important aim of this project is the application of forensic analysis to the cuneiform symbols to identify scribal hands. Cuneiform tablets are amongst the earliest records of written communication, and could be considered as one of the original information technologies; an accessible, portable and robust medium for communication across distance and time. The earliest examples are up to 5,000 years old, and the writing technique remained in use for some 3,000 years. Unfortunately, only a small fraction of these tablets can be made available for display in museums and much important academic work has yet to be performed on the very large numbers of tablets to which there is necessarily restricted access. Our paper will describe the challenges encountered in the 2D image capture of a sample set of tablets held in the British Museum, explaining the motivation for attempting 3D imaging and the results of initial experiments scanning the smaller, more densely inscribed cuneiform tablets. We will also discuss the tractability of 3D digital capture, representation and manipulation, and investigate the requirements for scaleable data compression and transmission methods. Additional information can be found on the project website: www.cuneiform.net
Resumo:
Purpose: To compare graticule and image capture assessment of the lower tear film meniscus height (TMH). Methods: Lower tear film meniscus height measures were taken in the right eyes of 55 healthy subjects at two study visits separated by 6 months. Two images of the TMH were captured in each subject with a digital camera attached to a slit-lamp biomicroscope and stored in a computer for future analysis. Using the best of two images, the TMH was quantified by manually drawing a line across the tear meniscus profile, following which the TMH was measured in pixels and converted into millimetres, where one pixel corresponded to 0.0018 mm. Additionally, graticule measures were carried out by direct observation using a calibrated graticule inserted into the same slit-lamp eyepiece. The graticule was calibrated so that actual readings, in 0.03 mm increments, could be made with a 40× ocular. Results: Smaller values of TMH were found in this study compared to previous studies. TMH, as measured with the image capture technique (0.13 ± 0.04 mm), was significantly greater (by approximately 0.01 ± 0.05 mm, p = 0.03) than that measured with the graticule technique (0.12 ± 0.05 mm). No bias was found across the range sampled. Repeatability of the TMH measurements taken at two study visits showed that graticule measures were significantly different (0.02 ± 0.05 mm, p = 0.01) and highly correlated (r = 0.52, p < 0.0001), whereas image capture measures were similar (0.01 ± 0.03 mm, p = 0.16), and also highly correlated (r = 0.56, p < 0.0001). Conclusions: Although graticule and image analysis techniques showed similar mean values for TMH, the image capture technique was more repeatable than the graticule technique and this can be attributed to the higher measurement resolution of the image capture (i.e. 0.0018 mm) compared to the graticule technique (i.e. 0.03 mm). © 2006 British Contact Lens Association.
Resumo:
In this paper, we proposed a new method using long digital straight segments (LDSSs) for fingerprint recognition based on such a discovery that LDSSs in fingerprints can accurately characterize the global structure of fingerprints. Different from the estimation of orientation using the slope of the straight segments, the length of LDSSs provides a measure for stability of the estimated orientation. In addition, each digital straight segment can be represented by four parameters: x-coordinate, y-coordinate, slope and length. As a result, only about 600 bytes are needed to store all the parameters of LDSSs of a fingerprint, as is much less than the storage orientation field needs. Finally, the LDSSs can well capture the structural information of local regions. Consequently, LDSSs are more feasible to apply to the matching process than orientation fields. The experiments conducted on fingerprint databases FVC2002 DB3a and DB4a show that our method is effective.