13 resultados para depth-of-focus

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the most appropriate analysis technique for the differentiation of multifocal intraocular lens (MIOL) designs using defocus curve assessment of visual capability.Methods:Four groups of fifteen subjects were implanted bilaterally with either monofocal intraocular lenses, refractive MIOLs, diffractive MIOLs, or a combination of refractive and diffractive MIOLs. Defocus curves between -5.0D and +1.5D were evaluated using an absolute and relative depth-of-focus method, the direct comparison method and a new 'Area-of-focus' metric. The results were correlated with a subjective perception of near and intermediate vision. Results:Neither depth-of-focus method of analysis were sensitive enough to differentiate between MIOL groups (p>0.05). The direct comparison method indicated that the refractive MIOL group performed better at +1.00, -1.00 and -1.50 D and worse at -3.00, -3.50, -4.00 and -5.00D compared to the diffractive MIOL group (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The incipient phase of presbyopia represents a loss in accommodative amplitude of approximately 3 dioptres between the ages of 35 and 45 and is the prelude to the need for a reading addition. The need to maintain single binocular vision during this period requires re-calibration of the correspondence between accommodation and vergence response. No previous study has specifically attempted to correlate change in accommodative status with the profile of oculomotor responses occurring within the incipient phase of presbyopia. Measurements were made of the amplitude of accommodation, stimulus and response AC/A ratios, CA/C ratio, tonic accommodation, tonic vergence, proximal vergence, vergence adaptation and accommodative adaptation of 38 subjects. Twenty subjects were aged 35 to 45 years of age and 10 subjects were aged 20 to 30 years of age at the commencement of the study. The measurements were repeated at four-monthly intervals for a total of two years. The results of this study fail to support the Hess-Gullstrand theory of presbyopia with evidence that the effort to produce a unit change in accommodation increases with age. The data obtained has enabled the analysis of how each individual oculomotor function varies with the decline in amplitude of accommodation. MATLAB/SIMULINK software has been used to assist in the analysis and to allow the amendment of existing models to represent accurately the ageing oculomotor system. This study has proposed that with the decline in the amplitude of accommodation there is an increase in the accommodative convergence response per unit of accommodative response. To compensate for this increase, evidence has been found of a decrease in tonic vergence with age. If this decline in tonic vergence is not sufficient to counteract the increase in accommodative convergence, it is proposed that the near vision response is limited to the maximum vergence response that can be tolerated, with the resulting lower accommodative response being compensated for by an increase in the subjective depth-of-focus. When the blur due to the decrease in accommodative response can no longer be tolerated, the first reading addition will be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Hamamatsu Video Area Analyser has been coupled with a modified Canon IR automatic optometer. This has allowed simultaneous recording of pupil diameter and accommodation response to be made both statically and continuously, a feature not common in previous studies. Experimental work concerned pupil and accommodation responses during near vision tasks under a variety of conditions. The effects of sustained near vision tasks on accommodation have usually been demonstrated by taking post-task measures under darkroom conditions. The possibility of similar effects on pupil diameter was assessed using static and continuous recordings following a near vision task. Results showed that is luminance levels remained unchanged by using a pre-and post-task bright-empty field then, although accommodation regressed to pre-task levels,pupil diameter remained for several minutes at the contstricted level induced by the task. An investigation into the effect of a sinusoidally-modulated blur-only accommodative stimulus on pupil response demonstrated that response may be reduced or absent despite robust accommodation responses. This suggests that blur-driven acommodation alone may not be sufficient to produce a pupil near response and that the presence of other cues may be necessary. Pupil response was investigated using a looming stimulus which produced an inferred-proximity cue. It was found that a pupil response could be induced which was in synchrony with the stimulus while closed-loop accommodation response was kept constant by the constraints of optical blur. The pupil diameter of young and elderly subjects undertaking a 5 minute reading task was measured to assess the contribution of pupil constriction to near vision function in terms of depth-of-focus. Results showed that in the young subjects pupil diameter was too large to have a significant effect on depth-of-focus although it may be increased in the elderly subjects. Pupil and accommodation reponses to a temporally-modulated stimulus containing all cues present in a normal visual environment was assessed and results showed that as stimulus temporal frequency increased, pupil response showed increasing phase lag relative to closed-loop accommodation. The results of this study suggest that it may be necessary to change the accepted view of the function of pupil response as part of the near vision triad and that further study would be of benefit in particular to designers of vision aids such as, for example, bifocal contact lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS. Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS. Four months after implantation best-corrected acuity was -0.01 ± 0.16 logMAR at distance and 0.60 ± 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 ± 0.38 D. The average dynamic amplitude of accommodation was 0.71 ± 0.47 D, with a lag behind the target of 0.50 ± 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 ± 0.28 D/mm). Subjective amplitude of accommodation was 2.24 ± 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS. The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis has focused on three key areas of interest for femtosecond micromachining and inscription. The first area is micromachining where the work has focused on the ability to process highly repeatable, high precision machining with often extremely complex geometrical structures with little or no damage. High aspect ratio features have been demonstrated in transparent materials, metals and ceramics. Etch depth control was demonstrated especially in the work on phase mask fabrication. Practical chemical sensing and microfluidic devices were also fabricated to demonstrate the capability of the techniques developed during this work. The second area is femtosecond inscription. Here, the work has utilised the non-linear absorption mechanisms associated with femtosecond pulse-material interactions to create highly localised refractive index changes in transparent materials to create complex 3D structures. The techniques employed were then utilised in the fabrication of Phase masks and Optical Coherence Tomography (OCT) phantom calibration artefacts both of which show the potential to fill voids in the development of the fields. This especially the case for the OCT phantoms where there exists no previous artefacts of known shape, allowing for the initial specification of parameters associated with the quality of OCT machines that are being taken up across the world in industry and research. Finally the third area of focus was the combination of all of the techniques developed through work in planar samples to create a range of artefacts in optical fibres. The development of techniques and methods for compensating for the geometrical complexities associated with working with the cylindrical samples with varying refractive indices allowed for fundamental inscription parameters to be examined, structures for use as power monitors and polarisers with the optical fibres and finally the combination of femtosecond inscription and ablation techniques to create a magnetic field sensor with an optical fibre coated in Terfenol-D with directional capability. Through the development of understanding, practical techniques and equipment the work presented here demonstrates several novel pieces of research in the field of femtosecond micromachining and inscription that has provided a broad range of related fields with practical devices that were previously unavailable or that would take great cost and time to facilitate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper contributes to the literature on the intra-firm diffusion of innovations by investigating the factors that affect the firm’s decision to adopt and use sets of complementary innovations. We define complementary innovations those innovations whose joint use generates super additive gains, i.e. the gain from the joint adoption is higher than the sum of the gains derived from the adoption of each innovation in isolation. From a theoretical perspective, we present a simple decision model, whereby the firm decides ‘whether’ and ‘how much’ to invest in each of the innovations under investigation based upon the expected profit gain from each possible combination of adoption and use. The model shows how the extent of complementarity among the innovations can affect the firm’s profit gains and therefore the likelihood that the firm will adopt these innovations jointly, rather than individually. From an empirical perspective, we focus on four sets of management practices, namely operating (OMP), monitoring (MMP), targets (TMP) and incentives (IMP) management practices. We show that these sets of practices, although to a different extent, are complementary to each other. Then, we construct a synthetic indicator of the depth of their use. The resulting intra-firm index is built to reflect not only the number of practices adopted but also the depth of their individual use and the extent of their complementarity. The empirical testing of the decision model is carried out using the evidence from the adoption behaviour of a sample of 1,238 UK establishments present in the 2004 Workplace Employment Relations Survey (WERS). Our empirical results show that the intra-firm profitability based model is a good model in that it can explain more of the variability of joint adoption than models based upon the variability of adoption and use of individual practices. We also investigate whether a number of firm specific and market characteristics by affecting the size of the gains (which the joint adoption of innovations can generate) may drive the intensity of use of the four innovations. We find that establishment size, whether foreign owned, whether exposed to an international market and the degree of homogeneity of the final product are important determinants of the intensity of the joint adoption of the four innovations. Most importantly, our results point out that the factors that the economics of innovation literature has been showing to affect the intensity of use of a technological innovation do also affect the intensity of use of sets of innovative management practices. However, they can explain only a small part of the diversity of their joint adoption use by the firms in the sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare distance and near visual performance with a zero-aberration aspheric intraocular lens (IOL) (Softec HD, Lenstec, Inc. FL, USA) with that of an otherwise identical, but spherical IOL (Softec 1). Setting: Department of Ophthalmology, Solihull Hospital, West Midlands, United Kingdom. Methods: This prospective study comprised 37 patients with a Softec 1 spherical IOL implanted in one eye, who underwent phacoemulsification and received the Softec HD aspheric IOL in the fellow eye. One month post-operatively, unaided distance and near vision, residual refraction, best spectacle corrected distance and near visual acuity, reading speed, pseudoaccommodation and photopic contrast sensitivity were recorded. Wavefront analysis enabled comparison of higher order aberrations between the IOLs. Results: Prior to surgery, the Softec 1 and Softec HD eyes were not significantly different. Post-operatively, unaided vision, best spectacle corrected visual acuity and residual refraction were not significantly different between the eyes, nor were there significant differences observed between the measured wavefront aberrations. Once implanted, the range of focus was significantly better in the Softec HD IOL eye than the Softec 1 IOL eye and, although reading speed was equivalent to the Softec 1 eye, the print size at which this could be achieved was significantly smaller. Conclusions: Depth of field was significantly improved with the aspheric IOL compared with the spherical IOL, without any compromise in distance visual performance between the two IOLs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis considers four broad areas:(i) ANALYSIS OF THE STRESS FIELD.(a) research studies, relevant to the British Social Services considering the cultural setting, and the rigor with which they were conducted; (b) models of stress, specifically examining the theoretical soundness and practical application of the Medical, Engineering and Transactional models;(c) organisational models of stress relating specifically to human service organisations.(ii) QUALITATIVE AND QUANTITATIVE RESEARCH METHODOLOGIES.(a) the appropriate application of each respective methodology and the particular usefulness of qualitative research designs; (b) the relevance of understanding the language and terminology associated with the subject area prior to the implementation of survey methods; (iii) FIELDWORK.(a) Phase 1. By use of focus groups, in-depth interviews and diary keeping amongst a small range of teams and managers, the Researcher develops a basic conceptual framework of stress within a Social Services context. In addition a small scale personality inventory was administered to participants.(b) Phase 2. This consisted of three key elements: 6 case studies in which the Researcher implements and appraises the impact of a range of intervention strategies designed to assist teams and their managers in dealing more effectively with stress; the administration of a large scale survey to all the field social work teams within the Social Services Department; an analysis of the user role within the stress process by way of two focus groups.(iv) THEORETICAL DEVELOPMENT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary aim of this research is to understand what constitutes management accounting and control (MACs) practice and how these control processes are implicated in the day to day work practices and operations of the organisation. It also examines the changes that happen in MACs practices over time as multiple actors within organisational settings interact with each other. I adopt a distinctive practice theory approach (i.e. sociomateriality) and the concept of imbrication in this research to show that MACs practices emerge from the entanglement between human/social agency and material/technological agency within an organisation. Changes in the pattern of MACs practices happens in imbrication processes which are produced as the two agencies entangle. The theoretical approach employed in this research offers an interesting and valuable lens which seeks to reveal the depth of these interactions and uncover the way in which the social and material imbricate. The theoretical framework helps to reveal how these constructions impact on and produce modifications of MACs practices. The exploration of the control practices at different hierarchical levels (i.e. from the operational to middle management and senior level management) using the concept of imbrication process also maps the dynamic flow of controls from operational to top management and vice versa in the organisation. The empirical data which is the focus of this research has been gathered from a case study of an organisation involved in a large vertically integrated palm oil industry company in Malaysia specifically the refinery sector. The palm oil industry is a significant industry in Malaysia as it contributed an average of 4.5% of Malaysian Gross Domestic Product, over the period 1990 -2010. The Malaysian palm oil industry also has a significant presence in global food oil supply where it contributed 26% of the total oils and fats global trade in 2010. The case organisation is a significant contributor to the Malaysian palm oil industry. The research access has provided an interesting opportunity to explore the interactions between different groups of people and material/technology in a relatively heavy process food industry setting. My research examines how these interactions shape and are shaped by control practices in a dynamic cycle of imbrications over both short and medium time periods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of FOCUS, which stands for Frailty Management Optimization through EIPAHA Commitments and Utilization of Stakeholders’ Input, is to reduce the burden of frailty in Europe. The partners are working on advancing knowledge of frailty detection, assessment, and management, including biological, clinical, cognitive and psychosocial markers, in order to change the paradigm of frailty care from acute intervention to prevention. FOCUS partners are working on ways to integrate the best available evidence from frailty-related screening tools, epidemiological and interventional studies into the care of frail people and their quality of life. Frail citizens in Italy, Poland and the UK and their caregivers are being called to express their views and their experiences with treatments and interventions aimed at improving quality of life. The FOCUS Consortium is developing pathways to leverage the knowledge available and to put it in the service of frail citizens. In order to reach out to the broadest audience possible, the FOCUS Platform for Knowledge Exchange and the platform for Scaling Up are being developed with the collaboration of stakeholders. The FOCUS project is a development of the work being done by the European Innovation Partnership on Active and Healthy Ageing (EIPAHA), which aims to increase the average healthy lifespan in Europe by 2020 while fostering sustainability of health/social care systems and innovation in Europe. The knowledge and tools developed by the FOCUS project, with input from stakeholders, will be deployed to all EIPAHA participants dealing with frail older citizens to support activities and optimize performance.