76 resultados para degeneration thesis

em Aston University Research Archive


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The thesis investigated progression of the central 10° visual field with structural changes at the macula in a cross-section of patients with varying degrees of agerelated macular degeneration (AMD). The relationships between structure and function were investigated for both standard and short-wavelength automated perimetry (SWAP). Factors known to influence the measure of visual field progression were considered, including the accuracy of the refractive correction on SWAP thresholds and the learning effect. Techniques of assessing the structure to function relationships between fundus images and the visual field were developed with computer programming and evaluated for repeatability. Drusen quantification of fundus photographs and retro-mode scanning laser ophthalmoscopic images was performed. Visual field progression was related to structural changes derived from both manual and automated methods. Principal Findings: • Visual field sensitivity declined with advancing stage of AMD. SWAP showed greater sensitivity to progressive changes than standard perimetry. • Defects were confined to the central 5°. SWAP defects occurred at similar locations but were deeper and wider than corresponding standard perimetry defects. • The central field became less uniform as severity of AMD increased. SWAP visual field indices of focal loss were of more importance when detecting early change in AMD, than indices of diffuse loss. • The decline in visual field sensitivity over stage of severity of AMD was not uniform, whereas a linear relationship was found between the automated measure of drusen area and visual field parameters. • Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. • Overcorrection of the refraction for the working distance in SWAP should be avoided in subjects with insufficient accommodative facility. • The perimetric learning effect in the 10° field did not differ significantly between normal subjects and AMD patients. • Subretinal deposits appeared more numerous in retro-mode imaging than in fundus photography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the leading cause for visual impairment and blindness registration in the developed world. Due to the large amounts of conflicting AMD research on the role of nutrition and antioxidant intake, it is difficult for patients and practitioners to determine which measures can be taken to slow down the disease progression. The aim of this research was to determine the beliefs and knowledge that patients with AMD have about nutrition, to identify whether their condition is preventing them from eating a healthy diet, and to discover what their diet consists of. For the initial study, 158 participants with AMD (mean age 79 ± 7.8 years) and 50 participants without AMD (mean age 67 ± 8 years) were recruited from the Macular Society helpline, or from optometric practice. Participants had a 25 minute telephone interview where a 36-question survey was completed. The survey elicited demographic information, and questions covered the knowledge that participants had on nutrition and their current diet. The results from this survey uncovered three major findings: 1) 100% of AMD participants felt that they do not have enough information and support from eye-care practitioners regarding nutrition, 2) AMD patients are confused over, and display a lack of knowledge of, which foods are beneficial for eye health and when and what nutritional supplements to take, evidenced by 65% of participants not taking the correct dosage 3) AMD patients are not eating enough nutrients that would be beneficial for their condition - consuming an average of 1.4mg of lutein and zeaxanthin rather than the recommended 10mg. A clinical decision-making aid was created as an intervention based upon these findings. The aim of the aid was to help eye-care practitioners give the correct nutritional advice to their patients. Founded on the AREDS 2 inclusion and exclusion criteria, practitioners are able to identify which patients could benefit from a nutritional supplement, and which patients could benefit from dietary modification. An evaluation of the aid with 72 qualified eye-care practitioners exhibited a statistically significant increase in confidence after using the aid for two weeks. An evaluation using 51 student optometrists showed a statistically significant increase in confidence and a statistically significant increase in appropriate management of patients after using the aid. This project has elicited findings that are significant for AMD patient education. It is hoped that through these studies, patients will receive consistent advice about the risk factors for AMD, the link between AMD and nutrition, and the importance of maintaining a healthy, well-balanced diet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Age-related macular degeneration (ARMD) is a major cause of irreversible visual loss in the elderly and a significant threat to their quality of life. Although low vision services often improve the functional outcomes of individuals with macular disease, it remains unclear whether or not they have any impact on quality of life. The principal aim of this study was to determine the effect of a hospital-based low vision clinic on the quality of life of individuals with ARMD. Methods: Forty patients with ARMD attended the low vision clinic at Milton Keynes University Hospital. Quality of life was measured with the vision-specific Low Vision Quality of Life (LVQOL) questionnaire and the general health EuroQol (EQ-5D-5L) questionnaire. Measures were completed at baseline (time zero, T0), and at three- (T3) and six-month (T6) follow-up visits. Results: The near visual acuity of individuals attending the low vision clinic for the first time improved significantly between visits T0 and T3 (p=0.005), reflecting the practiced use of their newly-dispensed low vision aids. As expected, there was no significant change in near acuity over this time period for existing patients. For both new and existing patients, a significant increase in LVQOL score was evident between visits T0 and T3, with a further significant improvement between T3 and T6. Similarly, there was a significant decrease in EQ-5D-5L questionnaire scores between visits T0 and T6. Conclusions: The higher LVQOL scores obtained at the end of the study period (T6) provide evidence that low vision services at Milton Keynes University Hospital served to improve patient quality of life. The reduction in EQ-5D-5L scores over the same time period suggests that low vision services also provide for an improvement in general health-related quality of life. Impact: The findings support the cause of low vision services to improve not only the vision and functional outcomes of individuals with macular disease but also their quality of life. Moreover, the findings suggest that a more efficient allocation of resources at low vision clinics may be possible through the standardisation of patient follow-up frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis I contribute to the understanding of the experience of living with Age-Related Macular Degeneration (AMD) and its impact on quality of life through the use of a pragmatically guided mixed methods approach. AMD is a condition resulting in the loss of central vision in old age which can have a huge impact on the lives of patients. This thesis includes: literature reviewing; qualitative meta-synthesis; surveys and descriptive statistics; observation; and analysis of in-depth interviewing, in order to build a picture of what it is like for older people to live with AMD. I present the findings from six separate studies each designed to answer specific research questions. I begin with a mixed methods study to determine how well the most commonly used measure of quality of life for AMD patients’ represents patient experiences. I then go on to investigate the experiences of patients with AMD through a meta-synthesis of qualitative research and finally present four of my own empirical studies three of which investigate the experiences of patients with different types of AMD: early dry AMD, treatable wet AMD and advanced wet AMD and the final study investigates what it is like for a couple living together with AMD. Throughout the qualitative studies I use Interpretative Phenomenological Analysis (IPA) to develop an understanding of the experiences and life contexts of patients with AMD. Through rigorous analysis, I identify a range of themes which highlight the shared and divergent experiences of individuals with AMD and the need to acknowledge patients’ past, present and potential future life contexts and experiences when providing services to older people with AMD. I relate the findings of the six studies to the wider psychological literature on chronic illness and make recommendations for services for patients with AMD to be provided holistically within a lifeworld-led health care model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The MacDQoL is an individualised measure of the impact of macular degeneration (MD) on quality of life (QoL). There is preliminary evidence of its psychometric properties and sensitivity to severity of MD. The aim of this study was to carry out further psychometric evaluation with a larger sample and investigate the measure's sensitivity to MD severity. Methods: Patients with MD (n = 156: 99 women, 57 men, mean age 79 ± 13 years), recruited from eye clinics (one NHS, one private) completed the MacDQoL by telephone interview and later underwent a clinic vision assessment including near and distance visual acuity (VA), comfortable near VA, contrast sensitivity, colour recognition, recovery from glare and presence or absence of distortion or scotoma in the central 10° of the visual field. Results: The completion rate for the MacDQoL items was 99.8%. Of the 26 items, three were dropped from the measure due to redundancy. A fourth was retained in the questionnaire but excluded when computing the scale score. Principal components analysis and Cronbach's alpha (0.944) supported combining the remaining 22 items in a single scale. Lower MacDQoL scores, indicating more negative impact of MD on QoL, were associated with poorer distance VA (better eye r = -0.431 p < 0.001; worse eye r = -0.350 p < 0.001; binocular vision r = -0.419 p < 0.001) and near VA (better eye r -0.326 p < 0.001; worse eye r = -0.226 p < 0.001; binocular vision r = -0.326 p < 0.001). Poorer MacDQoL scores were associated with poorer contrast sensitivity (better eye r = 0.392 p < 0.001; binocular vision r = 0.423 p < 0.001), poorer colour recognition (r = 0.417 p < 0.001) and poorer comfortable near VA (r = -0.283, p < 0.001). The MacDQoL differentiated between those with and without binocular scotoma (U = 1244 p < 0.001). Conclusion: The MacDQoL 22-item scale has excellent internal consistency reliability and a single-factor structure. The measure is acceptable to respondents and the generic QoL item, MD-specific QoL item and average weighted impact score are related to several measures of vision. The MacDQoL demonstrates that MD has considerable negative impact on many aspects of QoL, particularly independence, leisure activities, dealing with personal affairs and mobility. The measure may be valuable for use in clinical trials and routine clinical care. © 2005 Mitchell et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. Methods: EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) years). Measurements were made on two occasions separated by 1 year. Intrasession repeatability was assessed by repeating the measures after a 10 minute recovery period at the first visit. Distance visual acuity was measured with a logMAR chart, near visual acuity with a MNRead chart at 25 cm, contrast sensitivity with a Pelli-Robson chart, and the presence of central visual disturbance assessed with an Amsler grid. A questionnaire was used to assess self reported difficulties with glare recovery. Results: The average EMS recovery time was 11.0 (SD 8.9) seconds, decreasing by 1.6 (5.2) seconds on repeated measurement (p<0.05). EMS photostress recovery was not correlated with visual function measures or subjective difficulties with lights (p>0.05). EMS photostress recovery time did not predict those whose vision decreased over the following year compared with those among whom it remained stable. Conclusions: The EMS test is not a useful tool in determining the severity or progression of AMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pathological lesions in the form of extracellular protein deposits, intracellular inclusions and changes in cell morphology occur in the brain in the majority of neurodegenerative disorders. Studies of the presence, distribution, and molecular determinants of these lesions are often used to define individual disorders and to establish the mechanisms of lesion pathogenesis. In most disorders, however, the relationship between the appearance of a lesion and the underlying disease process is unclear. Two hypotheses are proposed which could explain this relationship: (i) lesions are the direct cause of the observed neurodegeneration ('causal' hypothesis); and (ii) lesions are a reaction to neurodegeneration ('reaction' hypothesis). These hypotheses are considered in relation to studies of the morphology and molecular determinants of lesions, the effects of gene mutations, degeneration induced by head injury, the effects of experimentally induced brain lesions, transgenic studies and the degeneration of anatomical pathways. The balance of evidence suggests that in many disorders, the appearance of the pathological lesions is a reaction to degenerative processes rather than being their cause. Such a conclusion has implications both for the classification of neurodegenerative disorders and for studies of disease pathogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The density of ballooned neurons (BN), tau-positive neurons with inclusion bodies (tau+ neurons), and tau-positive plaques (tau+ plaques) was determined in sections of the frontal, parietal, and temporal lobe in 12 patients with corticobasal degeneration (CBD). No significant differences in the mean density of BN and tau+ neurons were observed between neocortical regions. In the hippocampus, the densities of BN were significantly lower than in the neocortex, and densities of tau+ neurons were greater in sectors CA1 and CA2, compared with CA3 and CA4. Tau+ plaques were present in one or more brain regions in six patients. Significantly more BN were recorded in the lower (laminae V/VI) compared with the upper cortex (laminae I/II/III) but tau+ neurons were equally frequent in the upper and lower cortex. No significant correlations were observed between the densities of BN and tau+ neurons, but the densities of BN in the superior temporal gyrus and tau+ plaques in the frontal cortex were positively correlated with age. A principal components analysis (PCA) suggested that differences in the density of tau+ neurons in the frontal and motor cortex were the most important sources of variation between patients. In addition, one patient with a particularly high density of tau+ neurons in the hippocampus appeared to be atypical of the patient group studied. The data support the hypothesis that, although clinically heterogeneous, CBD is a pathologically distinct disorder. (C) 2000 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study tested three hypotheses: (1) that there is clustering of the neuronal cytoplasmic inclusions (NCI), astrocytic plaques (AP) and ballooned neurons (BN) in corticobasal degeneration (CBD), (2) that the clusters of NCI and BN are not spatially correlated, and (3) that the lesions are correlated with disease ‘stage’. In 50% of the regions, clusters of lesions were 400–800 µm in diameter and regularly distributed parallel to the tissue boundary. Clusters of NCI and BN were larger in laminae II/III and V/VI, respectively. In a third of regions, the clusters of BN and NCI were negatively spatially correlated. Cluster size of the BN in the parahippocampal gyrus (PHG) was positively correlated with disease ‘stage’. The data suggest the following: (1) degeneration of the cortico-cortical pathways in CBD, (2) clusters of NCI and BN may affect different anatomical pathways and (3) BN may develop after the NCI in the PHG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corticobasal degeneration (CBD) is a rare and progressive neurological disorder characterised by the presence of ballooned neurons (BN) and tau positive inclusions in neurons and glial cells. We studied the spatial patterns of the BN, tau positive neurons with inclusions (tau + neurons), and tau positive plaques in the neocortex and hippocampus in 12 cases of CBD. All lesions were aggregated into clusters and in many brain areas, the clusters were distributed in a regular pattern parallel to the tissue boundary. In the majority of cortical areas, the clusters of BN were larger in the lower compared with the upper laminae while the clusters of tau + neurons were larger in the upper laminae. Clusters of BN and tau + neurons were either negatively correlated or not significantly correlated in the upper and lower cortical laminae. Hence, BN and tau + lesions in CBD exhibit similar spatial patterns as lesions in Alzheimer's disease (AD), dementia with Lewy bodies (DLB) and Pick's disease (PD). The location, sizes and distribution of the clusters in the neocortex suggest that the tau + lesions may be associated with the degeneration of the feedforward and the BN the feedback cortico-cortical and/or the efferent cortical pathways. © 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the laminar distribution of the pathological changes in the frontal and temporal lobe in neuronal intermediate filament inclusion disease (NIFID). Method: The distribution of the alpha-intenexin-positive neuronal cytoplasmic inclusions (NCI), surviving neurons, swollen achromatic neurons (SN) and glial cell nuclei was studied across the cortex in gyri of the frontal and temporal lobe in 10 cases of NIFID. Results: The distribution of the NCI was highly variable within different gyri, a peak in the upper cortex, a bimodal distribution with peaks of density in the upper and lower laminae, or no significant variation in density across the cortex. The surviving neurons were either bimodally distributed or exhibited no significant change in density across the cortex. The SN and glial cell nuclei were most abundant in the lower cortical laminae. In half of the gyri, variations in density of the NCI across the cortex were positively correlated with the SN. In some gyri, the surviving neurons were positively correlated with the SN and negatively correlated with the glial cell nuclei. In addition, the SN and glial cell nuclei were positively correlated in over half the gyri studied. Conclusion: The data suggest that frontal and temporal lobe degeneration in NIFID characterized by NCI, SN, neuronal loss and gliosis extends across the cortical laminae with considerable variation between cases and gyri. alpha-internexin-positive neurons in the upper laminae appear to be particularly vulnerable. The gliosis appears to be largely correlated with the appearance of SN and with neuronal loss and not related to the NCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of vascular risk factors in various age-related pathologies has been extensively researched. Nevertheless, the haemodynamic disturbance occurring in various ocular and systemic vascular beds to impact upon ocular function remained largely unknown. The purpose of the following studies was to explore the presence and impact of both ocular and systemic vascular dysregulation as well as biochemical vascular risk factors in healthy elderly individuals and patients with age-related macular degeneration. Furthermore, the possible role was played by circulatory oxidative stress and its relationship with endothelial dysfunction at both ocular and systemic levels has also been investigated. There were four principal sections to the present work: 1. To assess the relationship between ocular and systemic anti-oxidative defence in healthy individuals The principal findings of this work were: -It has been shown that MPOD significantly and positively related with circulatory GSH levels. 2. To investigate macro- and microcirculation and oxidative stress in early AMD patients without overt systemic disease The principal findings of this work were: -AMD patients exhibit abnormal macrocirculation compared to the controls. -Blood GSSG level was significantly higher in early AMD patients than controls. -AMD patients showed abnormal microcirculation at retinal level compared. -In early AMD patients, retinal venous RT positively correlated with blood GSSG levels. 3. To assess the relationship between ocular vascular function and circulatory markers of endothelial dysfunction and CVD risk The principal findings of this work were: -Age had a positive effect on ET-1, vWF and slope of retinal arterial constriction in otherwise healthy individuals. -Even in otherwise healthy individuals, retinal arterial vascular function showed a significant correlation with circulatory markers of endothelial dysfunction and CVD risk. 4. To assess age-related changes in ANS and vascular function, and their relationship to retinal vascular function parameters The principal findings of this work were: -Elderly individuals demonstrated abnormal circadian changes of PSNS activity compared to middle-aged group. -Elderly groups showed higher ET-1 and vWF level as well as C-IMT and AIx, and also impaired retinal vascular function compared to the middle-aged group. -In the elderly group, impaired retinal vascular function significantly correlated with the dysregulation of PSNS activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.