7 resultados para daylight

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A free space quantum key distribution system has been demonstrated. Consideration has been given to factors such as field of view and spectral width, to cut down the deleterious effect from background light levels. Suitable optical sources such as lasers and RCLEDs have been investigated as well as optimal wavelength choices, always with a view to building a compact and robust system. The implementation of background reduction measures resulted in a system capable of operating in daylight conditions. An autonomous system was left running and generating shared key material continuously for over 7 days. © 2009 Published by Elsevier B.V..

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technique of remote sensing provides a unique view of the earth's surface and considerable areas can be surveyed in a short amount of time. The aim of this project was to evaluate whether remote sensing, particularly using the Airborne Thematic Mapper (ATM) with its wide spectral range, was capable of monitoring landfill sites within an urban environment with the aid of image processing and Geographical Information Systems (GIS) methods. The regions under study were in the West Midlands conurbation and consisted of a large area in what is locally known as the Black Country containing heavy industry intermingled with residential areas, and a large single active landfill in north Birmingham. When waste is collected in large volumes it decays and gives off pollutants. These pollutants, landfill gas and leachate (a liquid effluent), are known to be injurious to vegetation and can cause stress and death. Vegetation under stress can exhibit a physiological change, detectable by the remote sensing systems used. The chemical and biological reactions that create the pollutants are exothermic and the gas and leachate, if they leave the waste, can be warmer than their surroundings. Thermal imagery from the ATM (daylight and dawn) and thermal video were obtained and used to find thermal anomalies on the area under study. The results showed that vegetation stress is not a reliable indicator of landfill gas migration, as sites within an urban environment have a cover too complex for the effects to be identified. Gas emissions from two sites were successfully detected by all the thermal imagery with the thermal ATM being the best. Although the results were somewhat disappointing, recent technical advancements in the remote sensing systems used in this project would allow geo-registration of ATM imagery taken on different occasions and the elimination of the effects of solar insolation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A literature review revealed that very little work has been conducted to investigate the possible benefits of coloured interventions on reading performance in low vision due to ARMD, under conditions that are similar to the real world reading environment. Further studies on the use of colour, as a rehabilitative intervention in low vision would therefore be useful. A series of objective, subject based, age-similar controlled experiments were used to address the primary aims. Trends in some of the ARMD data suggested better reading performance with blue or green illuminance but there were also some individuals who performed better with yellow, or with illuminance of reduced intensity. Statistically, better reading in general occurred with a specialised yellow photochromic lens and also a clear lens than with a fixed lens or a neutral density filter. No reading advantage was gained from using the coloured screen facility of a video-magnifier. Some subjects with low vision were found to have co-existent binocular vision anomalies, which may have caused reading difficulties similar to those produced by ARMD. Some individuals with ARMD benefited from the use of increased local illuminance produced by either a standard tungsten or compact fluorescent lamp. No reading improvement occurred with a daylight simulation tungsten lamp. The Intuitive Colorimeter® can be used to detect and map out colour vision discrimination deficiency in ARMD and the Humphrey 630 Visual Field Analyser can be used to analyse the biocular visual field in subjects with ARMD. Some experiments highlighted a positive effect of a blue intervention in reading with ARMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contact lenses seem to be the ideal method of vision correction for ametropic people who participate in sporting activities. This thesis sets out to evaluate the viewpoint of the optometric professional and that of the patient on the use of contact lenses in sport and to establish if education is needed within this area. It also aims to provide some scientific evidence on the effect of exercise on the physiology of the cornea with and without contact lenses. Silicone hydrogel contact lenses have previously been suggested to impede heat dissipation from the cornea compared to mid water hydrogels. This was further demonstrated with exercise. The physiological integrity of the cornea is dependant on the amount of oxygen available to its surfaces. Contact lenses can disrupt the diffusion of oxygen to the cornea. Previous methods of measuring the oxygen consumption of the cornea have been limited by their invasive nature and assessment of only a small surface area of the cornea. They are not suitable to measure corneal oxygen consumption during exercise with and without contact lenses. A new method needed to be established. This was achieved by designing a novel method by the use of an oxygen sensor inside an airtight goggle using dynamic quenching of luminescence method. This established a non-contact way of measuring the effect oxygen uptake with and without contact lenses in vivo, allowing the contact lens to be undisturbed in their natural environment. The new method differentiated between the closed-eye and the open-eye condition with a good within-visit repeatability. It also illustrated that the cornea utilises oxygen at a faster rate during controlled aerobic exercise at moderate intensity. New contact lenses are available specifically for sport, these claim to reduce glare and increase contrast for daylight outdoor sports. However, visual benefits of these types of contact lenses cannot be measured easily in an indoor clinical environment, such as the optometric practice. To demonstrate any potential benefits of these lenses emulation of them should be conducted outdoors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Environmental conditions early in life may imprint the circadian system and influence response to environmental signals later in life. We previously determined that a large springtime increase in solar insolation at the onset location was associated with a younger age of onset of bipolar disorder, especially with a family history of mood disorders. This study investigated whether the hours of daylight at the birth location affected this association. Methods: Data collected previously at 36 collection sites from 23 countries were available for 3896 patients with bipolar I disorder, born between latitudes of 1.4N and 70.7N, and 1.2S and 41.3S. Hours of daylight variables for the birth location were added to a base model to assess the relation between the age of onset and solar insolation. Results: More hours of daylight at the birth location during early life was associated with an older age of onset, suggesting reduced vulnerability to the future circadian challenge of the springtime increase in solar insolation at the onset location. Addition of the minimum of the average monthly hours of daylight during the first 3 months of life improved the base model, with a significant positive relationship to age of onset. Coefficients for all other variables remained stable, significant and consistent with the base model. Conclusions: Light exposure during early life may have important consequences for those who are susceptible to bipolar disorder, especially at latitudes with little natural light in winter. This study indirectly supports the concept that early life exposure to light may affect the long term adaptability to respond to a circadian challenge later in life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate colour vision testing requires using the correct illumination. With the plethora of 'daylight' lamps available, is there a cost-effective alternative to the discontinued MacBeth Easel lamp? Smoking is a known risk factor for macula degeneration. As the macula is responsible for colour discrimination, any toxin that affects it has the potential to influence colour discrimination. Aims: To find a costeffective light source for colour vision testing. To investigate the effect of smoking on colour discrimination. To explore how deuteranomalous trichromats compare with normal trichromats. Methods: Using the Ishihara colour vision test subjects were classified into the groups: 'Normal/Control', 'Smoker/Test', and 'Case Study' (subjects who failed the screening test and did not smoke). They completed the Farnsworth Munsell 100 Hue test under each of the three light sources: Phillips EcoHalo Twist (tungsten halogen - THL), Kosnic KCF07ALU/GU10-865 (compact fluorescent- CFL), and Deal Guardian Ltd. GU103X2WA4B-60 (light-emitting diode - LED) Results: 42 subjects took part in the study: 18 in the Normal/Control group, 18 in the Smoker/Test group, and 6 in the Case Study group. For the Normal/Control group the total error scores (TESs) were significantly lower with the CFL than with the THL (p = 0.017) as it was for the Case Study group (p = 0.009). No significant differences were found between the Normal/Control group and the Smoker/Test group for each light source. Decision tree analysis found pack years to be a significant variable for TES. Discussion: All three light sources were comparable with previous studies. The CFL provided better colour discrimination than the LED despite them both being 6500 K. Deuteranomalous trichromats showed a greatest deviation than normal trichromats using the LED. Conclusions: The Kosnic KCF07ALU/GU10-865 is a cost-effective alternative for colour vision testing. Smoking appears to have an effect on colour vision, but requires further investigation.