3 resultados para correlation distance

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the correlation between tests of visual function and perceived visual ability recorded with a 'quality-of-life' questionnaire for patients with central field loss. Method: 12 females and 7 males (mean age = 53.1 years; Range = 23 - 80 years) with subfoveal neovascular membranes underwent a comprehensive assessment of visual function. Tests included unaided distance vision, high and low contrast distance logMAR visual acuity (VA), Pelli-Robson contrast senstivity (at 1m), near logMAR word VA and text reading speed. All tests were done both monocularly and binocularly. The patients also completed a 28 point questionnaire separated into a 'core' section consisting of general questions about perceived visual function and a 'module' section with specific questions on reading function. Results: Step-wise multiple regression analysis was used to determine which visual function tests were correlated with the patients's perceived visual function and to rank them in order of importance. The visual function test that explains most of the variance in both 'core' score (66%0 and the 'module' score (68%) of the questionnaire is low contrast VA in the better eye (P<0.001 in both cases). Further, the module score also accounts for a significant proportion of the variance (P<0.01) of the distance logMAR VA in both the better and worse eye, and the near logMAR in both the better eye and binocularly. Conclusions: The best predictor of both perceived reading ability and of general perceived visual ability in this study is low contrast logMAR VA. The results highlight that distance VA is not the only relevant measure of visual fucntion in relation to a patients's perceived visual performance and should not be considered a determinant of surgical or management success.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The aim was to investigate the effect on the measured amplitude of accommodation and repeatability of using the minus lens technique with the target at distance or near. Methods: Forty-three students (average age: 21.17 ± 1.50 years, 35 female) had their amplitude of accommodation measured with minus lenses on top of their distance correction in a trial frame with the target at far (6.0m) or near (0.4m). The minus lens power was gradually added with steps of 0.25D. Measurements were taken on two occasions at each distance, which were separated by a time interval of at least 24 hours. Results: The measured amplitude at six metres was significantly lower than that with the target at 40cm, by 1.56 ± 1.17D (p < 0.001) and this varied between individuals (r = 0.716, intraclass correlation coefficient = 0.439). With either target distance, repeated measurement was highly correlated (r > 0.9) but the agreement was better at 6.0m (±0.74D) than at 40cm (± 0.92D). Conclusion: The measurements of the amplitude of accommodation with the minus lens technique using targets at far or near are not comparable and the difference between the target distances may provide clinically relevant information. © 2013 Optometrists Association Australia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high resolution optical time domain reflectometry (OTDR) based on an all-fiber chaotic source is demonstrated. We analyze the key factors limiting the operational range of such an OTDR, e.g., integral Rayleigh backscattering and the fiber loss, which degrade the optical signal to noise ratio at the receiver side, and then the guideline for counter-act such signal fading is discussed. The experimentally demonstrated correlation OTDR presents ability of 100km sensing range and 8.2cm spatial resolution (1.2 million resolved points), as a verification of the theoretical analysis. To the best of our knowledge, this is the first time that correlation OTDR measurement is performed over such a long distance with such high precision.