Background and aims: Diabetic Retinopathy (DR) is a leading cause of blindness. OSA is associated with increased oxidative and nitrosative stress and endothelial dysfunction in patients with type 2 diabetes (T2DM). Hence, it is plausible that OSA can promote the development and progression of DR. Materials and methods: An observational longitudinal study in adults with T2DM. Patients with pre-existing OSA, end-stage renal disease and non-diabetic retinopathy were excluded. OSA (apnoea hypopnea index ≥ 5 events/hour) was assessed by a single overnight home-based cardio-respiratory monitoring (Alice PDX, etc.). DR was assesses using retinal images between 2007 and 2012. Sight threatening retinopathy (STR) was defined as pre-proliferative or proliferative DR, maculopathy or photocoagulation. Advanced DR was defined as pre-proliferative or proliferative DR. Results: 199 patients were included (57.3% men, 47.7% White Europeans). STR and OSA prevalence were 38.7 % and 62.8% respectively. STR preva-lence was higher in patients with OSA (OSA+) compared to those with-out (OSA-) [48.8% vs. 21.6%, p <0.001]. After adjustment for confounders, OSA remained independently associated with STR (OR 3.7, 95%CI 1.6-8.9, p=0.006, maculopathy (OR 4.5, 1.8-11.4, p=0.002) and advanced DR (OR 3.9, 1.02-15.3, p=0.047). Over 4.4±1 years, more OSA+ patients progressed from no or background DR to advanced DR (15.3% vs. 3%, p=0.01). OSA was an independent predictor of advanced DR development after adjustment (OR 6.6, 95%CI 1.2-35.1, p=0.03). OSA did not predict the development of maculopathy. Patients received continuous positive airway pressure treatment were less likely to develop advanced DR. Conclusion: OSA is independently associated with STR and predicts the development of preproliferative and proliferative DR. Interventional studies are needed to assess the impact of OSA treatment on DR.Supported by: NIHR (UK) and The UK Novo Nordisk Research Foundation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.