16 resultados para clinical setting

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human fundus is a complex structure that can be easily visualized and the world of ophthalmology is going through a golden era of new and exciting fundus imaging techniques; recent advances in technology have allowed a significant improvement in the imaging modalities clinicians have available to formulate a diagnostic and treatment plan for the patient, but there is constant on-going work to improve current technology and create new ideas in order to gather as much information as possible from the human fundus. In this article we shall summarize the imaging techniques available in the standard medical retina clinic (i.e. not limited to the research lab) and delineate the technologies that we believe will have a significant impact on the way clinicians will assess retinal and choroidal pathology in the not too distant future.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Visual perception is dependent on both light transmission through the eye and neuronal conduction through the visual pathway. Advances in clinical diagnostics and treatment modalities over recent years have increased the opportunities to improve the optical path and retinal image quality. Higher order aberrations and retinal straylight are two major factors that influence light transmission through the eye and ultimately, visual outcome. Recent technological advancements have brought these important factors into the clinical domain, however the potential applications of these tools and considerations regarding interpretation of data are much underestimated. The purpose of this thesis was to validate and optimise wavefront analysers and a new clinical tool for the objective evaluation of intraocular scatter. The application of these methods in a clinical setting involving a range of conditions was also explored. The work was divided into two principal sections: 1. Wavefront Aberrometry: optimisation, validation and clinical application The main findings of this work were: • Observer manipulation of the aberrometer increases variability by a factor of 3. • Ocular misalignment can profoundly affect reliability, notably for off-axis aberrations. • Aberrations measured with wavefront analysers using different principles are not interchangeable, with poor relationships and significant differences between values. • Instrument myopia of around 0.30D is induced when performing wavefront analysis in non-cyclopleged eyes; values can be as high as 3D, being higher as the baseline level of myopia decreases. Associated accommodation changes may result in relevant changes to the aberration profile, particularly with respect to spherical aberration. • Young adult healthy Caucasian eyes have significantly more spherical aberration than Asian eyes when matched for age, gender, axial length and refractive error. Axial length is significantly correlated with most components of the aberration profile. 2. Intraocular light scatter: Evaluation of subjective measures and validation and application of a new objective method utilising clinically derived wavefront patterns. The main findings of this work were: • Subjective measures of clinical straylight are highly repeatable. Three measurements are suggested as the optimum number for increased reliability. • Significant differences in straylight values were found for contact lenses designed for contrast enhancement compared to clear lenses of the same design and material specifications. Specifically, grey/green tints induced significantly higher values of retinal straylight. • Wavefront patterns from a commercial Hartmann-Shack device can be used to obtain objective measures of scatter and are well correlated with subjective straylight values. • Perceived retinal stray light was similar in groups of patients implanted with monofocal and multi focal intraocular lenses. Correlation between objective and subjective measurements of scatter is poor, possibly due to different illumination conditions between the testing procedures, or a neural component which may alter with age. Careful acquisition results in highly reproducible in vivo measures of higher order aberrations; however, data from different devices are not interchangeable which brings the accuracy of measurement into question. Objective measures of intraocular straylight can be derived from clinical aberrometry and may be of great diagnostic and management importance in the future.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The purpose of this study was to investigate the 12-month outcome of macular edema secondary to both chronic and new central and branch retinal vein occlusions treated with intravitreal bevacizumab in the real-life clinical setting in the UK. Methods: Retrospective case notes analysis of consecutive patients with retinal vein occlusions treated with bevacizumab in 2010 to 2012. Outcome measures were visual acuity (measured with Snellen, converted into logMAR [logarithm of the minimum angle of resolution] for statistical calculation) and central retinal thickness at baseline, 4 weeks post-loading phase, and at 1 year. Results: There were 56 and 100 patients with central and branch retinal vein occlusions, respectively, of whom 62% had chronic edema and received prior therapies and another 32% required additional laser treatments post-baseline bevacizumab. Baseline median visual acuity was 0.78 (interquartile range [IQR] 0.48–1.22) in the central group and 0.6 (IQR 0.3–0.78) in the branch group. In both groups, visual improvement was statistically significant from baseline compared to post-loading (P,0.001 and P=0.03, respectively), but was not significant by month 12 (P=0.058 and P=0.166, respectively); 30% improved by at least three lines and 44% improved by at least one line by month 12. Baseline median central retinal thickness was 449 μm (IQR 388–553) in the central group and 441 µm (IQR 357–501) in the branch group. However, the mean reduction in thickness was statistically significant at post-loading (P,0.001) and at the 12-month time point (P,0.001) for both groups. The average number of injections in 1 year was 4.2 in the central group and 3.3 in the branch group. Conclusion: Our large real-world cohort results indicate that bevacizumab introduced to patients with either new or chronic edema due to retinal vein occlusion can result in resolution of edema and stabilization of vision in the first year.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To design and validate a vision-specific quality-of-life assessment tool to be used in a clinical setting to evaluate low-vision rehabilitation strategy and management. METHODS: Previous vision-related questionnaires were assessed by low-vision rehabilitation professionals and patients for relevance and coverage. The 74 items selected were pretested to ensure correct interpretation. One hundred and fifty patients with low vision completed the chosen questions on four occasions to allow the selection of the most appropriate items. The vision-specific quality of life of patients with low vision was compared with that of 70 age-matched and gender-matched patients with normal vision and before and after low-vision rehabilitation in 278 patients. RESULTS: Items that were unreliable, internally inconsistent, redundant, or not relevant were excluded, resulting in the 25-item Low Vision Quality-of-Life Questionnaire (LVQOL). Completion of the LVQOL results in a summed score between 0 (a low quality of life) and 125 (a high quality of life). The LVQOL has a high internal consistency (α = 0.88) and good reliability (0.72). The average LVQOL score for a population with low vision (60.9 ± 25.1) was significantly lower than the average score of those with normal vision (100.3 ± 20.8). Rehabilitation improved the LVQOL score of those with low vision by an average of 6.8 ± 15.6 (17%). CONCLUSIONS: The LVQOL was shown to be an internally consistent, reliable, and fast method for measuring the vision-specific quality of life of the visually impaired in a clinical setting. It is able to quantify the quality of life of those with low vision and is useful in determining the effects of low-vision rehabilitation. Copyright (C) 2000 Elsevier Science Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: Persistent contamination of surfaces by spores of Clostridium difficile is a major factor influencing the spread of C. difficile-associated diarrhoea (CDAD) in the clinical setting. In recent years, the antimicrobial efficacy of metal surfaces has been investigated against microorganisms including methicillin-resistant Staphylococcus aureus. This study compared the survival of C. difficile on stainless steel, a metal contact surface widely used in hospitals, and copper surfaces. METHODS: Antimicrobial efficacy was assessed using a carrier test method against dormant spores, germinating spores and vegetative cells of C. difficile (NCTC 11204 and ribotype 027) over a 3 h period in the presence and absence of organic matter. RESULTS: Copper metal eliminated all vegetative cells of C. difficile within 30 min, compared with stainless steel which demonstrated no antimicrobial activity (P < 0.05). Copper significantly reduced the viability of spores of C. difficile exposed to the germinant (sodium taurocholate) in aerobic conditions within 60 min (P < 0.05) while achieving a >or=2.5 log reduction (99.8% reduction) at 3 h. Organic material did not reduce the antimicrobial efficacy of the copper surface (P > 0.05).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The environment may act as a reservoir for pathogens that cause healthcare-associated infections (HCAIs). Approaches to reducing environmental microbial contamination in addition to cleaning are thus worthy of consideration. Copper is well recognised as having antimicrobial activity but this property has not been applied to the clinical setting. We explored its use in a novel cross-over study on an acute medical ward. A toilet seat, set of tap handles and a ward entrance door push plate each containing copper were sampled for the presence of micro-organisms and compared to equivalent standard, non-copper-containing items on the same ward. Items were sampled once weekly for 10 weeks at 07:00 and 17:00. After five weeks, the copper-containing and non-copper-containing items were interchanged. The total aerobic microbial counts per cm2 including the presence of ‘indicator micro-organisms’ were determined. Median numbers of microorganisms harboured by the copper-containing items were between 90% and 100% lower than their control equivalents at both 07:00 and 17:00. This reached statistical significance for each item with one exception. Based on the median total aerobic cfu counts from the study period, five out of ten control sample points and zero out of ten copper points failed proposed benchmark values of a total aerobic count of <5 cfu/cm2. All indicator micro-organisms were only isolated from control items with the exception of one item during one week. The use of copper-containing materials for surfaces in the hospital environment may therefore be a valuable adjunct for the prevention of HCAIs and requires further evaluation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Although numerous studies and metanalysis have shown the beneficial effect of statin therapy in CVD secondary prevention, there is still controversy such the use of statins for primary CVD prevention in patients with DM. The purpose of this study was to evaluate the occurrence of total major adverse cardio-vascular events (MACE) in a cohort of patients with type 2 diabetes complicated by nephropathy treated with statins, in order to verify real life effect of statin on CVD primary prevention. Methods: We conducted an observational prospective multicenter study on 564 patients with type 2 diabetic nephropathy free of cardiovascular disease attending 21 national outpatient diabetes clinics and followed them up for 8 years. 169 of them were treated with statins (group A) while 395 were not on statins (group B). Results: Notably, none of the patients was treated with a high-intensity statin therapy according to last ADA position statement. Total MACE occurred in 32 patients from group A and in 68 patients from group B. Fatal MACE occurred in 13 patients from group A and in 30 from group B; nonfatal MACE occurred in 19 patients from group A and in 38 patients from group B. The analysis of the Kaplan-Meier survival curves showed a not statistically significant difference in the incidence of total (p 0.758), fatal (p 0.474) and nonfatal (p 0.812) MACE between the two groups. HbA1c only showed a significant difference in the incidence of MACE between the two groups (HR 1.201, CI 1.041-1.387, p 0.012). Conclusions: These findings suggest that, in a real clinical setting, moderate-intensity statin treatment is ineffective in cardiovascular primary prevention for patients with diabetic nephropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare distance and near visual performance with a zero-aberration aspheric intraocular lens (IOL) (Softec HD, Lenstec, Inc. FL, USA) with that of an otherwise identical, but spherical IOL (Softec 1). Setting: Department of Ophthalmology, Solihull Hospital, West Midlands, United Kingdom. Methods: This prospective study comprised 37 patients with a Softec 1 spherical IOL implanted in one eye, who underwent phacoemulsification and received the Softec HD aspheric IOL in the fellow eye. One month post-operatively, unaided distance and near vision, residual refraction, best spectacle corrected distance and near visual acuity, reading speed, pseudoaccommodation and photopic contrast sensitivity were recorded. Wavefront analysis enabled comparison of higher order aberrations between the IOLs. Results: Prior to surgery, the Softec 1 and Softec HD eyes were not significantly different. Post-operatively, unaided vision, best spectacle corrected visual acuity and residual refraction were not significantly different between the eyes, nor were there significant differences observed between the measured wavefront aberrations. Once implanted, the range of focus was significantly better in the Softec HD IOL eye than the Softec 1 IOL eye and, although reading speed was equivalent to the Softec 1 eye, the print size at which this could be achieved was significantly smaller. Conclusions: Depth of field was significantly improved with the aspheric IOL compared with the spherical IOL, without any compromise in distance visual performance between the two IOLs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To determine whether copper incorporated into hospital ward furnishings and equipment can reduce their surface microbial load. Design. A crossover study. Setting. Acute care medical ward with 19 beds at a large university hospital. Methods. Fourteen types of frequent-touch items made of copper alloy were installed in various locations on an acute care medical ward. These included door handles and push plates, toilet seats and flush handles, grab rails, light switches and pull cord toggles, sockets, overbed tables, dressing trolleys, commodes, taps, and sink fittings. Their surfaces and those of equivalent standard items on the same ward were sampled once weekly for 24 weeks. The copper and standard items were switched over after 12 weeks of sampling to reduce bias in usage patterns. The total aerobic microbial counts and the presence of indicator microorganisms were determined. Results. Eight of the 14 copper item types had microbial counts on their surfaces that were significantly lower than counts on standard materials. The other 6 copper item types had reduced microbial numbers on their surfaces, compared with microbial counts on standard items, but the reduction did not reach statistical significance. Indicator microorganisms were recovered from both types of surfaces; however, significantly fewer copper surfaces were contaminated with vancomycin-resistant enterococci, methicillin-susceptible Staphylococcus aureus, and coliforms, compared with standard surfaces. Conclusions. Copper alloys (greater than or equal to 58% copper), when incorporated into various hospital furnishings and fittings, reduce the surface microorganisms. The use of copper in combination with optimal infection-prevention strategies may therefore further reduce the risk that patients will acquire infection in healthcare environments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the performance of an aspheric diffractive multifocal acrylic intraocular lens (IOL), ZMB00 1-Piece Tecnis. Setting: Five sites across Europe. Methods: Fifty-two patients with cataracts (average age 68.5±10.5 years, 35 female) were bilaterally implanted with the aspheric diffractive multifocal IOL after completing a questionnaire regarding their optical visual symptoms, use of visual correction and their visual satisfaction. The questionnaire was completed again 4-6 months after surgery along with measures of uncorrected and best-corrected distance and near visual acuity, under photopic and mesopic lighting, reading ability, defocus curve testing and ocular examination for adverse events. Results: The residual refractive error was 0.01±0.47D with 56% of eyes within ±0.25D and 97% within ±1.0D. Uncorrected visual acuity was 0.02±0.10logMAR at distance and 0.15±0.30 logMAR at near, only reducing to 0.07±0.10logMAR at distance and 0.21±0.25logMAR at near in mesopic conditions.The defocus curve showed a near addition between 2.5-3.0 D allowing a reading acuity of 0.08±0.13 logMAR, with a range of clear vision <0.3 logMAR of ∼4.0 D. The average reading speed was 121.4±30.8 words per minute. Spectacle independence was 100% for distance and 88% for near, with high levels of satisfaction reported. Overall rating of vision without glasses could be explained (r=0.760) by preoperative best-corrected distance acuity, postoperative reading acuity and postoperative uncorrected distance acuity in photopic conditions (p<0.001). Only two minor adverse events occurred. Conclusions: The ZMB00 1-Piece Tecnis multifocal IOL provides a good visual outcome at distance and near with minimal adverse effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To analyze, in a general population sample, clustering of delusional and hallucinatory experiences in relation to environmental exposures and clinical parameters. METHOD: General population-based household surveys of randomly selected adults between 18 and 65 years of age were carried out. SETTING: 52 countries participating in the World Health Organization's World Health Survey were included. PARTICIPANTS: 225 842 subjects (55.6% women), from nationally representative samples, with an individual response rate of 98.5% within households participated. RESULTS: Compared with isolated delusions and hallucinations, co-occurrence of the two phenomena was associated with poorer outcome including worse general health and functioning status (OR = 0.93; 95% CI: 0.92-0.93), greater severity of symptoms (OR = 2.5 95% CI: 2.0-3.0), higher probability of lifetime diagnosis of psychotic disorder (OR = 12.9; 95% CI: 11.5-14.4), lifetime treatment for psychotic disorder (OR = 19.7; 95% CI: 17.3-22.5), and depression during the last 12 months (OR = 11.6; 95% CI: 10.9-12.4). Co-occurrence was also associated with adversity and hearing problems (OR = 2.0; 95% CI: 1.8-2.3). CONCLUSION: The results suggest that the co-occurrence of hallucinations and delusions in populations is not random but instead can be seen, compared with either phenomenon in isolation, as the result of more etiologic loading leading to a more severe clinical state.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Heavy menstrual bleeding (HMB) is a common problem, yet evidence to inform decisions about initial medical treatment is limited. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of the levonorgestrel-releasing intrauterine system (LNG-IUS) (Mirena(®), Bayer) compared with usual medical treatment, with exploration of women's perspectives on treatment. DESIGN: A pragmatic, multicentre randomised trial with an economic evaluation and a longitudinal qualitative study. SETTING: Women who presented in primary care. PARTICIPANTS: A total of 571 women with HMB. A purposeful sample of 27 women who were randomised or ineligible owing to treatment preference participated in semistructured face-to-face interviews around 2 and 12 months after commencing treatment. INTERVENTIONS: LNG-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined oestrogen-progestogen or progesterone alone). Women could subsequently swap or cease their allocated treatment. OUTCOME MEASURES: The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period and then again at 5 years. Secondary outcomes included general quality of life (QoL), sexual activity, surgical intervention and safety. Data were analysed using iterative constant comparison. A state transition model-based cost-utility analysis was undertaken alongside the randomised trial. Quality-adjusted life-years (QALYs) were derived from the European Quality of Life-5 Dimensions (EQ-5D) and the Short Form questionnaire-6 Dimensions (SF-6D). The intention-to-treat analyses were reported as cost per QALY gained. Uncertainty was explored by conducting both deterministic and probabilistic sensitivity analyses. RESULTS: The MMAS total scores improved significantly in both groups at all time points, but were significantly greater for the LNG-IUS than for usual treatment [mean difference over 2 years was 13.4 points, 95% confidence interval (CI) 9.9 to 16.9 points; p < 0.001]. However, this difference between groups was reduced and no longer significant by 5 years (mean difference in scores 3.9 points, 95% CI -0.6 to 8.3 points; p = 0.09). By 5 years, only 47% of women had a LNG-IUS in place and 15% were still taking usual medical treatment. Five-year surgery rates were low, at 20%, and were similar, irrespective of initial treatments. There were no significant differences in serious adverse events between groups. Using the EQ-5D, at 2 years, the relative cost-effectiveness of the LNG-IUS compared with usual medical treatment was £1600 per QALY, which by 5 years was reduced to £114 per QALY. Using the SF-6D, usual medical treatment dominates the LNG-IUS. The qualitative findings show that women's experiences and expectations of medical treatments for HMB vary considerably and change over time. Women had high expectations of a prompt effect from medical treatments. CONCLUSIONS: The LNG-IUS, compared with usual medical therapies, resulted in greater improvement over 2 years in women's assessments of the effect of HMB on their daily routine, including work, social and family life, and psychological and physical well-being. At 5 years, the differences were no longer significant. A similar low proportion of women required surgical intervention in both groups. The LNG-IUS is cost-effective in both the short and medium term, using the method generally recommended by the National Institute for Health and Care Excellence. Using the alternative measures to value QoL will have a considerable impact on cost-effectiveness decisions. It will be important to explore the clinical and health-care trajectories of the ECLIPSE (clinical effectiveness and cost-effectiveness of levonorgestrel-releasing intrauterine system in primary care against standard treatment for menorrhagia) trial participants to 10 years, by which time half of the cohort will have reached menopause. TRIAL REGISTRATION: Current Controlled Trials ISRCTN86566246. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 88. See the NIHR Journals Library website for further project information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuropsychiatry services provide specialist input into the assessment and management of behavioral symptoms associated with a range of neurological conditions, including epilepsy. Despite the centrality of epilepsy to neuropsychiatry and the recent expansion of neuropsychiatry service provision, little is known about the clinical characteristics of patients with epilepsy who are routinely seen by a specialist neuropsychiatry service. This retrospective study filled this gap by retrospectively evaluating a naturalistic series of 60 consecutive patients with epilepsy referred to and assessed within a neuropsychiatry setting. Fifty-two patients (86.7%) had active epilepsy and were under the ongoing care of the referring neurologist for seizure management. The majority of patients (N = 42; 70.0%) had a diagnosis of localization-related epilepsy, with temporal lobe epilepsy as the most common epilepsy type (N = 37; 61.7%). Following clinical assessment, 39 patients (65.0%) fulfilled formal diagnostic criteria for at least one psychiatric disorder; nonepileptic attack disorder (N = 37; 61.7%), major depression (N = 23; 38.3%), and generalized anxiety disorder (N = 16; 26.7%) were the most commonly diagnosed comorbidities. The clinical characteristics of patients seen in specialist neuropsychiatry settings are in line with the results from previous studies in neurology clinics in terms of both epilepsy and psychiatric comorbidity. Our findings confirm the need for the development and implementation of structured care pathways for the neuropsychiatric aspects of epilepsy, with focus on comorbid nonepileptic attacks and affective and anxiety symptoms. This is of particular importance in consideration of the impact of behavioral symptoms on patients' health-related quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In December 2007, the National Institute for Health and Clinical Excellence and the National Patient Safety Agency in the UK (NICE-NPSA) published guidance that recommends all adults admitted to hospital receive medication reconciliation, usually by pharmacy staff. A costing and report tool was provided indicating a resource requirement of d12.9 million for England per year. Pediatric patients are excluded from this guidance. Objective: To determine the clinical significance of medication reconciliation in children on admission to hospital. Methods: A prospective observational study included pediatric patients admitted to a neurosurgical ward at Birmingham Childrens Hospital, Birmingham, England, between September 2006 and March 2007. Medication reconciliation was conducted by a pharmacist after the admission of each of 100 consecutive eligible patients aged 4 months to 16 years. The clinical significance of prescribing disparities between pre-admission medications and initial admission medication orders was determined by an expert multidisciplinary panel and quantified using an analog scale. The main outcome measure was the clinical signficance of unintentional variations between hospital admission medication orders and physician-prescribed pre-admission medication for repeat (continuing) medications. Results: Initial admission medication orders for children differed from prescribed pre-admission medication in 39%of cases. Half of all resulting prescribing variations in this setting had the potential to cause moderate or severe discomfort or clinical deterioration. These results mirror findings for adults. Conclusions: The introduction of medication reconciliation in children on admission to hospital has the potential to reduce discomfort or clinical deterioration by reducing unintentional changes to repeat prescribed medication. Consequently, there is no justification for the omission of children from the NICENPSA guidance concerning medication reconciliation in hospitals, and costing tools should include pediatric patients. © 2010 Adis Data Information BV. All rights reserved.