14 resultados para clinical practice guidelines

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Myopia is a global public health issue; however, no information exists as to how potential myopia retardation strategies are being adopted globally. METHODS: A self-administrated, internet-based questionnaire was distributed in six languages, through professional bodies to eye care practitioners globally. The questions examined: awareness of increasing myopia prevalence, perceived efficacy and adoption of available strategies, and reasons for not adopting specific strategies. RESULTS: Of the 971 respondents, concern was higher (median 9/10) in Asia than in any other continent (7/10, p<0.001) and they considered themselves more active in implementing myopia control strategies (8/10) than Australasia and Europe (7/10), with North (4/10) and South America (5/10) being least proactive (p<0.001). Orthokeratology was perceived to be the most effective method of myopia control, followed by increased time outdoors and pharmaceutical approaches, with under-correction and single vision spectacles felt to be the least effective (p<0.05). Although significant intra-regional differences existed, overall most practitioners 67.5 (±37.8)% prescribed single vision spectacles or contact lenses as the primary mode of correction for myopic patients. The main justifications for their reluctance to prescribe alternatives to single vision refractive corrections were increased cost (35.6%), inadequate information (33.3%) and the unpredictability of outcomes (28.2%). CONCLUSIONS: Regardless of practitioners' awareness of the efficacy of myopia control techniques, the vast majority still prescribe single vision interventions to young myopes. In view of the increasing prevalence of myopia and existing evidence for interventions to slow myopia progression, clear guidelines for myopia management need to be established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso-zeaxanthin on macular pigment optical density measurement techniques published in peer-reviewed journals, through a multi-staged, systematic approach. Twenty-four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naïve subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20 mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20 mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last decade, researchers in the social sciences have increasingly adopted neuroscientific techniques, with the consequent rise of research inspired by neuroscience in disciplines such as economics, marketing, decision sciences, and leadership. In 2007, we introduced the term organizational cognitive neuroscience (OCN), in an attempt to clearly demarcate research carried out in these many areas, and provide an overarching paradigm for research utilizing cognitive neuroscientific methods, theories, and concepts, within the organizational and business research fields. Here we will revisit and further refine the OCN paradigm, and define an approach where we feel the marriage of organizational theory and neuroscience will return even greater dividends in the future and that is within the field of clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The purpose of this study was to investigate the 12-month outcome of macular edema secondary to both chronic and new central and branch retinal vein occlusions treated with intravitreal bevacizumab in the real-life clinical setting in the UK. Methods: Retrospective case notes analysis of consecutive patients with retinal vein occlusions treated with bevacizumab in 2010 to 2012. Outcome measures were visual acuity (measured with Snellen, converted into logMAR [logarithm of the minimum angle of resolution] for statistical calculation) and central retinal thickness at baseline, 4 weeks post-loading phase, and at 1 year. Results: There were 56 and 100 patients with central and branch retinal vein occlusions, respectively, of whom 62% had chronic edema and received prior therapies and another 32% required additional laser treatments post-baseline bevacizumab. Baseline median visual acuity was 0.78 (interquartile range [IQR] 0.48–1.22) in the central group and 0.6 (IQR 0.3–0.78) in the branch group. In both groups, visual improvement was statistically significant from baseline compared to post-loading (P,0.001 and P=0.03, respectively), but was not significant by month 12 (P=0.058 and P=0.166, respectively); 30% improved by at least three lines and 44% improved by at least one line by month 12. Baseline median central retinal thickness was 449 μm (IQR 388–553) in the central group and 441 µm (IQR 357–501) in the branch group. However, the mean reduction in thickness was statistically significant at post-loading (P,0.001) and at the 12-month time point (P,0.001) for both groups. The average number of injections in 1 year was 4.2 in the central group and 3.3 in the branch group. Conclusion: Our large real-world cohort results indicate that bevacizumab introduced to patients with either new or chronic edema due to retinal vein occlusion can result in resolution of edema and stabilization of vision in the first year.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To assess and explain deviations from recommended practice in National Institute for Clinical Excellence (NICE) guidelines in relation to fetal heart monitoring. Design: Qualitative study. Setting: Large teaching hospital in the UK. Sample: Sixty-six hours of observation of 25 labours and interviews with 20 midwives of varying grades. Methods: Structured observations of labour and semistructured interviews with midwives. Interviews were undertaken using a prompt guide, audiotaped, and transcribed verbatim. Analysis was based on the constant comparative method, assisted by QSR N5 software. Main outcome measures: Deviations from recommended practice in relation to fetal monitoring and insights into why these occur. Results: All babies involved in the study were safely delivered, but 243 deviations from recommended practice in relation to NICE guidelines on fetal monitoring were identified, with the majority (80%) of these occurring in relation to documentation. Other deviations from recommended practice included indications for use of electronic fetal heart monitoring and conduct of fetal heart monitoring. There is evidence of difficulties with availability and maintenance of equipment, and some deficits in staff knowledge and skill. Differing orientations towards fetal monitoring were reported by midwives, which were likely to have impacts on practice. The initiation, management, and interpretation of fetal heart monitoring is complex and distributed across time, space, and professional boundaries, and practices in relation to fetal heart monitoring need to be understood within an organisational and social context. Conclusion: Some deviations from best practice guidelines may be rectified through straightforward interventions including improved systems for managing equipment and training. Other deviations from recommended practice need to be understood as the outcomes of complex processes that are likely to defy easy resolution. © RCOG 2006.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The Respiratory Health Network in Western Australia developed the Asthma Model of Care in 2010 which incorporates best practice guidelines. At the same time short-acting beta agonist guidelines (SABA) were developed by stakeholder consensus at University of Western Australia (UWA) and incorporated the use of an Asthma Action Plan Card. Objective: To report on the implementation of a key component of the WA Asthma Model of Care, the SABA guidelines that incorporate the Asthma Action Plan card. Methods: Implementation strategies included lectures, direct pharmacy detailing, media releases, and information packs (postal and electronic). Groups targeted included pharmacists, consumers and medical practitioners. Results: State-based (n=18) and national (n=6) professional organisations were informed about the launch of the guidelines into practice in WA. In the four-month implementation period more than 47,000 Asthma Action Plan Cards were distributed, primarily to community pharmacies. More than 500 pharmacies were provided with information packs or individual detailing. More than 10,000 consumers were provided with information about the guidelines. Conclusions and implications: The collaboration of stakeholders in this project allowed for widespread access to various portals which, in turn, resulted in a multifaceted approach in disseminating information. Ongoing maintenance programs are required to sustain and build on the momentum of the implementation program and to ultimately address patient outcomes and practice change, which would be the longer-term goals of such a project. Future research will seek to ascertain the impact of the card on patient outcomes in WA.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The societal cost for the average health authority in the United Kingdom for the care of wet age-related macular degeneration (AMD) has been suggested to be around £7.4 million. It is vital that the best possible care based on the best available evidence is provided to reduce the impact of AMD on patients' lives and the financial cost to the health-care system. This study explored the experiences of AMD patients treated with intravitreal ranibizumab injections. Three semistructured interviews were conducted with seven participants over the course of 18 months. Transcripts were analysed using interpretative phenomenological analysis. Analysis identified four themes: preparing for treatment, the treatment process, patient-provider communication, and results of treatment. Patient experiences highlighted the need to move away from the reliance on letters for information provision, and the need for clearer guidelines about when to cease AMD treatment. Interviews highlighted the need for the inclusion of rigorous qualitative evidence with experiential data in future good clinical practice guideline development for AMD. © The Author(s) 2013.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ocular allergy is a common eye condition encountered in clinical practice. However, little is known how seasonal allergic conjunctivitis (SAC), the most common subtype, is managed in clinical practice. Further, dry eye, another common eye condition, may be misdiagnosed as SAC and vice-versa as they share similar signs and symptoms. In addition, despite the frequent recommendation of non-pharmacological treatments for SAC, evidenceto support their use has not been identified in the scientific literature. The aim of this thesis was therefore to determine the actual diagnosis and management of SAC and dry eye in clinical practice and investigate the efficacy of non-pharmacological treatments for these conditions. The diagnostic and management strategies for SAC and dry eye employed by pharmacy staff are found to be inconsistent with current guidelines and scientific evidence based upon a mystery shopper design. Cluster analysis of tear film metrics in normal and dry eye patients identified several clinically relevant groups of patients that may allow for targeted treatment recommendations. Using a novel environmental chamber model of SAC, the use of artificial tears and cold compresses, either alone or combined is an effective treatment modality for acute and symptomatic SAC, on a par with topical anti-allergic medication, and has been demonstrated for the first time. In addition, eyelid warming therapy with a simple, readily available, seed filled device is an effective method of treating meibomian gland dysfunction (MGD) related evaporative dry eye, perhaps the most common dry eye subtype. A greater focus on ophthalmology must be implemented as part of the formal education and training of pharmacy staff, while greater professional communication between community pharmacists, optometrists and the population they serve is required. Artificial tears and cold compresses may be considered as front line agents for acute SAC by pharmacy staff and optometrists, to whom pharmacological treatment options are limited.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: To examine the use of image analysis to quantify changes in ocular physiology. Method: A purpose designed computer program was written to objectively quantify bulbar hyperaemia, tarsal redness, corneal staining and tarsal staining. Thresholding, colour extraction and edge detection paradigms were investigated. The repeatability (stability) of each technique to changes in image luminance was assessed. A clinical pictorial grading scale was analysed to examine the repeatability and validity of the chosen image analysis technique. Results: Edge detection using a 3 × 3 kernel was found to be the most stable to changes in image luminance (2.6% over a +60 to -90% luminance range) and correlated well with the CCLRU scale images of bulbar hyperaemia (r = 0.96), corneal staining (r = 0.85) and the staining of palpebral roughness (r = 0.96). Extraction of the red colour plane demonstrated the best correlation-sensitivity combination for palpebral hyperaemia (r = 0.96). Repeatability variability was <0.5%. Conclusions: Digital imaging, in conjunction with computerised image analysis, allows objective, clinically valid and repeatable quantification of ocular features. It offers the possibility of improved diagnosis and monitoring of changes in ocular physiology in clinical practice. © 2003 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The risk-to-benefit ratio for the use of low dose of aspirin in primary cardiovascular (CV) prevention in patients with diabetes mellitus remains to be clarified. We assessed the effect of aspirin on risk of CV events in type 2 diabetic patients with nephropathy, in order to verify the usefulness of Guidelines in clinical practice. We carried out a prospective multicentric study in 564 patients with type 2 diabetic nephropathy free of CV disease attending outpatient diabetes clinics. A total of 242 patients received antiplatelet treatment with aspirin 100 mg/day (group A), and 322 were not treated with antiplatelet drugs (group B). Primary end point was the occurrence of total major adverse cardio-vascular events (MACE). Secondary end points were the relative occurrence of fatal MACE. The average follow-up was 8 years. Total MACE occurred in 49 patients from group A and in 52 patients from group B. Fatal MACE occurred in 22 patients from group A and in 20 from group B; nonfatal MACE occurred in 27 patients from group A and in 32 patients from group B. Kaplan-Meier analysis did not show a statistically significant difference of cumulative MACE between the two groups. A not statistically significant difference in the incidence of both fatal (p = 0.225) and nonfatal CV events (p = 0.573) between the two groups was observed. These results were confirmed after adjustment for confounders (HR for MACE 1.11, 95 % CI 0.91-1.35). These findings suggest that low dose of aspirin is ineffective in primary prevention for patients with nephropathy. © 2014 Springer-Verlag Italia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aims : Our aim was to investigate the proportional representation of people of South Asian origin in cardiovascular outcome trials of glucose-lowering drugs or strategies in Type 2 diabetes, noting that these are among the most significant pieces of evidence used to formulate the guidelines on which clinical practice is largely based. Methods : We searched for cardiovascular outcome trials in Type 2 diabetes published before January 2015, and extracted data on the ethnicity of participants. These were compared against expected values for proportional representation of South Asian individuals, based on population data from the USA, from the UK, and globally. Results : Twelve studies met our inclusion criteria and, of these, eight presented a sufficiently detailed breakdown of participant ethnicity to permit numerical analysis. In general, people of South Asian origin were found to be under-represented in trials compared with UK and global expectations and over-represented compared with US expectations. Among the eight trials for which South Asian representation could be reliably estimated, seven under-represented this group relative to the 11.2% of the UK diabetes population estimated to be South Asian, with the representation in these trials ranging from 0.0% to 10.0%. Conclusions : Clinicians should exercise caution when generalizing the results of trials to their own practice, with regard to the ethnicity of individuals. Efforts should be made to improve reporting of ethnicity and improve diversity in trial recruitment, although we acknowledge that there are challenges that must be overcome to make this a reality.