8 resultados para artificial surface cracks

em Aston University Research Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The nature of subsurface cracks formed under and around Vickers hardness indentations is often assumed rather than identified. Subsurface cracks in four engineering ceramics are revealed using a penetrant technique, and flaw dimensions are recorded. The resulting data are used to investigate several aspects of indentation cracking, such as crack shape, functional relationships between indentation load and flaw dimensions, and the performance of indentation fracture toughness equations. An R curve is constructed for each of the materials. © 1995 The Institute of Materials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, different artificial neural networks (ANN) are developed for the prediction of surface roughness (R a) values in Al alloy 7075-T7351 after face milling machining process. The radial base (RBNN), feed forward (FFNN), and generalized regression (GRNN) networks were selected, and the data used for training these networks were derived from experiments conducted using a high-speed milling machine. The Taguchi design of experiment was applied to reduce the time and cost of the experiments. From this study, the performance of each ANN used in this research was measured with the mean square error percentage and it was observed that FFNN achieved the best results. Also the Pearson correlation coefficient was calculated to analyze the correlation between the five inputs (cutting speed, feed per tooth, axial depth of cut, chip°s width, and chip°s thickness) selected for the network with the selected output (surface roughness). Results showed a strong correlation between the chip thickness and the surface roughness followed by the cutting speed. © ASM International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sample of run-off water from a vertical, slate rock surface in Wales, U.K. contained abundant fragments of the lichen Parmelia glabratula ssp. fuliginosa from about 0.6 to 8.0 mm in diameter, a few fragments of Parmelia conspersa from 0.6 to 4.0 mm in diameter and a large number of unidentified propagules from 0.2 to 0.5 mm in diameter. The colonization of permanent plots on the rock surface was studied over six years. At the end of the experiment relatively few thalli of Parmelia conspersa, Parmelia glabratula ssp. fuliginosa and Buellia aethalea had established in plots on undisturbed and newly-exposed slate. Fragments (2 mm in diameter) of Parmelia conspersa placed on horizontal pieces of slate survived up to 120 days in cracks, 20 days on a thin smear of bird droppings but only 2-3 days on smooth slate, against small joints in the rock or in small holes. Isidia of Parmelia conspersa placed on horizontal pieces of slate established equally in plots on smooth undisturbed slate and in plots on the surface exposed after the removal of large Parmelia conspersa thalli, but less well on newly-exposed slate. These results suggest that lichen propagules are abundant in run-off water but establishment is a hazardous process. This may be attributable to a shortage of suitable sites on the substratum for attachment of propagules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Derivatives of L-histidine were investigated as suitable models for the Asp-His couple found in the catalytic triad of serine proteases. A combination of molecular dynamics and IH NMR spectroscopy suggested that the most populous conformations of N-acetyl-L-histidine and the N-acetyl-L-histidine anion were predominated by those in which the carboxylate group was gauche to the imidazole ring overcoming steric and electrostatic repulsion, suggesting there is an interaction between the carboxylate group and the imidazole ring. Kinetic studies, using imidazole, N-acetyl-L-histidine and the N-acetyl-L-histidine anion showed that in a DMSO/H20 9: 1 v/v solution, the N-acetyl-L-histidine anion catalysed the hydrolysis of p-nitrophenyl acetate at a greater rate than using either imidazole or N-acetyl-L-histidine as catalyst. This indicates that the carboxylate group affects the nucleophilicity of the unprotonated imidazole ring. 31P MAS NMR spectroscopy was investigated as a new technique for the study of the template molecule environment within the polymer networks. It was found that it was possible to distinguish between template associated with the polymer and that which was precipitated onto the surface, though it was not possible to distinguish between polymer within imprinted cavities and that which was not. Attempts to study the effect of the carboxylate group/imidazole ring interaction in the imprinted cavity of a molecularly imprinted polymer network were hindered by the method used to follow the reaction. It was found though that in a pH 8.0 buffered solution the presence of imprinted cavities increased the rate of reaction for those polymers derived from L-histidine. Some preliminary investigations into the design and synthesis of an MIP which would catalyse the oxy-Cope rearrangement were carried out but the results were inconclusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel biosensing system based on a micromachined rectangular silicon membrane is proposed and investigated in this paper. A distributive sensing scheme is designed to monitor the dynamics of the sensing structure. An artificial neural network is used to process the measured data and to identify cell presence and density. Without specifying any particular bio-application, the investigation is mainly concentrated on the performance testing of this kind of biosensor as a general biosensing platform. The biosensing experiments on the microfabricated membranes involve seeding different cell densities onto the sensing surface of membrane, and measuring the corresponding dynamics information of each tested silicon membrane in the form of a series of frequency response functions (FRFs). All of those experiments are carried out in cell culture medium to simulate a practical working environment. The EA.hy 926 endothelial cell lines are chosen in this paper for the bio-experiments. The EA.hy 926 endothelial cell lines represent a particular class of biological particles that have irregular shapes, non-uniform density and uncertain growth behaviour, which are difficult to monitor using the traditional biosensors. The final predicted results reveal that the methodology of a neural-network based algorithm to perform the feature identification of cells from distributive sensory measurement has great potential in biosensing applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This project is concerned with the deterioration of surface coatings as a result of weathering and exposure to a pollutant gas (in this case nitric oxide). Poly(vinyl chloride) (PVC) plastisol surface coatings have been exposed to natural and artificial weathering and a comparison of the effects of these two types of weathering has been made by use of various analytical techniques. These techniques have each been assessed as to their value in providing information regarding changes taking place in the coatings during ageing, and include, goniophotometry, micro-penetrometry, surface energy measurements, weight loss measurements, thermal analysis and scanning electron microscopy. The results of each of these studies have then been combined to show the changes undergone by PVC plastisol surface coatings during ageing and to show the effects which additives to the coatings have on their behaviour and in particular the effects of plasticiser, pigment and uv and thermal stabilisers. Finally a preliminary study of the interaction between five commercial polymers and nitric oxide has been carried out, the polymers being polypropylene, cellulose acetate butyrate, polystyrene, polyethylene terephthalate and polycarbonate. Each of the samples was examined using infra-red spectroscopy in the transmission mode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knoop and Vickers indentation cracks have frequently been used as model 'precracks' in ceramic bend specimens for fracture toughness (K1c) determination. Indentation residual stress reduces the measured K1c but can be removed or accounted for by grinding, annealing, or modelling. Values of K1c are obtained for four materials using Vickers indentations and an improved stress intensity factor. Methods for residual stress removal or incorporation are compared, and the most reliable stress removal alternative is identified for each material. © 1996 The Institute of Materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dry eye disease is a common clinical condition whose aetiology and management challenges clinicians and researchers alike. Practitioners have a number of dry eye tests available to clinically assess dry eye disease, in order to treat their patients effectively and successfully. This thesis set out to determine the most relevant and successful key tests for dry eye disease diagnosis/ management. There has been very little research on determining the most effective treatment options for these patients; therefore a randomised controlled study was conducted in order to see how different artificial treatments perform compared to each other, whether the preferred treatment could have been predicted from their ocular clinical assessment, and if the preferred treatment subjectively related to the greatest improvement in ocular physiology and tear film stability. This research has found: 1. From the plethora of ocular the tear tests available to utilise in clinical practice, the tear stability tests as measured by the non-invasive tear break (NITBUT) up time and invasive tear break up time (NaFL TBUT) are strongly correlated. The tear volume tests are also related as measured by the phenol red thread (PRT) and tear meniscus height (TMH). Lid Parallel Conjunctival Folds (LIPCOF) and conjunctival staining are significantly correlated to one another. Symptomology and osmolarity were also found to be important tests in order to assess for dry eye. 2. Artificial tear supplements do work for ocular comfort, as well as the ocular surface as observed by conjunctival staining and the reduction LIPCOF. There is no strong evidence of one type of artificial tear supplement being more effective than others, and the data suggest that these improvements are more due to the time than the specific drops. 3. When trying to predict patient preference for artificial tears from baseline measurements, the individual category of artificial tear supplements appeared to have an improvement in at least 1 tear metric. Undoubtedly, from the study the patients preferred artificial tear supplements’ were rated much higher than the other three drops used in the study and their subjective responses were statistically significant than the signs. 4. Patients are also willing to pay for a community dry eye service in their area of £17. In conclusion, the dry eye tests conducted in the study correlate with one another and with the symptoms reported by the patient. Artificial tears do make a difference objectively as well as subjectively. There is no optimum artificial treatment for dry eye, however regular consistent use of artificial eye drops will improve the ocular surface.