3 resultados para angular deformations

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modified polarization spectroscopy method was applied for determination of angular momenta of autoionizing states of Pu in multistep resonance ionization processes. In comparison with the known one, our method does not require circular polarization at all, only linear polarizations are needed. This simplicity was reached using a three-dimensional excitation geometry. Angular momenta of nine new autoionizing <sup>242</sup>Pu states were determined. The method suggested could be applied for efficiency improvement in multistep RIMS applications as well as for the odd-even isotope separation for elements with a J = 0 ground state (Pu, Yb, Sm etc.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model is developed for the general pneumatic tyre. The model will permit the investigations of tyre deformations produced by arbitrary external loading, and will enable estimates to be made of the distributions of applied and reactive forces. The principle of Finite Elements is used to idealise the composite tyre structure, each element consisting of a triangle of double curvature with varying thickness. Large deflections of' the structure are accomodated by the use of an iterative sequence of small incremental steps, each of' which obeys the laws of linear mechanics. The theoretical results are found to compare favourably with the experimental test data obtained from two different types of ttye construction. However, limitations in the discretisation process has prohibited accurate assessments to be made of stress distributions in the regions of high stress gradients ..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper details work carried out to verify the dimensional measurement performance of the Indoor GPS (iGPS) system; a network of Rotary-Laser Automatic Theodolites (R-LATs). Initially tests were carried out to determine the angular uncertainties on an individual R-LAT transmitter-receiver pair. A method is presented of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. Further tests carried out on a highly optimized version of the iGPS system have shown that the coordinate uncertainty can be reduced to 0.25 mm at a 95% confidence level.