12 resultados para Word and image

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The essential first step for a beginning reader is to learn to match printed forms to phonological representations. For a new word, this is an effortful process where each grapheme must be translated individually (serial decoding). The role of phonological awareness in developing a decoding strategy is well known. We examined whether beginner readers recruit different skills depending on the nature of the words being read (familiar words vs. nonwords). Print knowledge, phoneme and rhyme awareness, rapid automatized naming (RAN), phonological short term memory (STM), nonverbal reasoning, vocabulary, auditory skills and visual attention were measured in 392 pre-readers aged 4 to 5 years. Word and nonword reading were measured 9 months later. We used structural equation modeling to examine the skills-reading relationship and modeled correlations between our two reading outcomes and among all pre-reading skills. We found that a broad range of skills were associated with reading outcomes: early print knowledge, phonological STM, phoneme awareness and RAN. Whereas all these skills were directly predictive of nonword reading, early print knowledge was the only direct predictor of word reading. Our findings suggest that beginner readers draw most heavily on their existing print knowledge to read familiar words.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare graticule and image capture assessment of the lower tear film meniscus height (TMH). Methods: Lower tear film meniscus height measures were taken in the right eyes of 55 healthy subjects at two study visits separated by 6 months. Two images of the TMH were captured in each subject with a digital camera attached to a slit-lamp biomicroscope and stored in a computer for future analysis. Using the best of two images, the TMH was quantified by manually drawing a line across the tear meniscus profile, following which the TMH was measured in pixels and converted into millimetres, where one pixel corresponded to 0.0018 mm. Additionally, graticule measures were carried out by direct observation using a calibrated graticule inserted into the same slit-lamp eyepiece. The graticule was calibrated so that actual readings, in 0.03 mm increments, could be made with a 40× ocular. Results: Smaller values of TMH were found in this study compared to previous studies. TMH, as measured with the image capture technique (0.13 ± 0.04 mm), was significantly greater (by approximately 0.01 ± 0.05 mm, p = 0.03) than that measured with the graticule technique (0.12 ± 0.05 mm). No bias was found across the range sampled. Repeatability of the TMH measurements taken at two study visits showed that graticule measures were significantly different (0.02 ± 0.05 mm, p = 0.01) and highly correlated (r = 0.52, p < 0.0001), whereas image capture measures were similar (0.01 ± 0.03 mm, p = 0.16), and also highly correlated (r = 0.56, p < 0.0001). Conclusions: Although graticule and image analysis techniques showed similar mean values for TMH, the image capture technique was more repeatable than the graticule technique and this can be attributed to the higher measurement resolution of the image capture (i.e. 0.0018 mm) compared to the graticule technique (i.e. 0.03 mm). © 2006 British Contact Lens Association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Five linepipe type steels were produced in order to study the effect of calcium and magnesium injection on their final properties. Two of these steels were at the extremes of the sulphide range i.e. 0.003 and 0.017% sulphur with no injection attempted; thereby, providing standards to compare with the injected steels. The oxygen level varied from 21 to 63 p.p.m. The cast ingots were controlled-rolled and isothermally rolled in order to study the deformation characteristics of the residual non-metallic inclusions. The structure and cleanliness of these steels was evaluated metallographically using the light microscope, SEM, and image analysis and the results related to their Charpy toughness and HIC resistance. Increasing sulphur levels decreased final properties of the steel. In the untreated state, with as little as 0.003% sulphur, test orientation was highly influential. Modification of sulphur bearing steels was achieved with low modifying element to sulphur ratios provided that the oxygen content was very low. Injection of calcium into steel caused interaction with oxide and sulphide inclusions which was biased toward oxide reduction relative to sulphur removal. Magnesium again reduced oxides and appeared to be linked with aluminia containing inclusions in the final product. It produced improved toughness values relative to a similar sulphur containing calcium treated steel. The results of this work could be extended to establish the mechanism of inclusion modification with magnesium additions to sulphur bearing steels.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To assess the stability of the Akreos AO intraocular lens (IOL) platform with a simulated toric design using objective image analysis. Setting: Six hospital eye clinics across Europe. Methods: After implantation in 1 eye of patients, IOLs with orientation marks were imaged at 1 to 2 days, 7 to 14 days, 30 to 60 days, and 120 to 180 days. The axis of rotation and IOL centration were objectively assessed using validated image analysis. Results: The study enrolled 107 patients with a mean age of 69.9 years ± 7.7 (SD). The image quality was sufficient for IOL rotation analysis in 91% of eyes. The mean rotation between the first day postoperatively and 120 to 180 days was 1.93 ± 2.33 degrees, with 96% of IOLs rotating fewer than 5 degrees and 99% rotating fewer than 10 degrees. There was no significant rotation between visits and no clear bias in the direction of rotation. In 71% of eyes, the dilation and image quality was sufficient for image analysis of centration. The mean change in centration between 1 day and 120 to 180 days was 0.21 ± 0.11 mm, with all IOLs decentering less than 0.5 mm. There was no significant decentration between visits and no clear bias in the direction of the decentration. Conclusion: Objective analysis of digital retroillumination images taken at different postoperative periods shows the aspheric IOL platform was stable in the eye and is therefore suitable for the application of a toric surface to correct corneal astigmatism.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this chapter we present the relevant mathematical background to address two well defined signal and image processing problems. Namely, the problem of structured noise filtering and the problem of interpolation of missing data. The former is addressed by recourse to oblique projection based techniques whilst the latter, which can be considered equivalent to impulsive noise filtering, is tackled by appropriate interpolation methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study compares interpreter-mediated face-to-face Magistrates Court hearings with those conducted through prison video link in which interpreters are located in court and non- English-speaking defendants in prison. It seeks to examine the impact that the presence of video link has on court actors in terms of interaction and behaviour. The data comprises 11 audio-recordings of face-to-face hearings, 10 recordings of prison video link hearings, semistructured interviews with 27 court actors, and ethnographic observation of hearings as viewed by defendants in Wormwood Scrubs prison in London. The over-arching theme is the pervasive influence of the ecology of the courtroom upon all court actors in interpretermediated hearings and thus on the communication process. Close analysis of the court transcripts shows that their relative proximity to one another can be a determinant of status, interpreting role, mode and volume. The very few legal protocols which apply to interpretermediated cases (acknowledging and ratifying the interpreter, for example), are often forgotten or dispensed with. Court interpreters lack proper training in the specific challenges of court interpreting, whether they are co-present with the defendant or not. Other court actors often misunderstand the interpreter’s role. This has probably come about because courts have adjusted their perceptions of what they think interpreters are supposed to do based on their own experiences of working with them, and have gradually come to accept poor practice (the inability to perform simultaneous interpreting, for example) as the norm. In video link courts, mismatches of sound and image due to court clerks’ failure to adequately track current speakers, poor image and sound quality and the fact that non-English-speaking defendants in pre-and post-court consultations can see and hear interpreters but not their defence advocates are just some of the additional layers of disadvantage and confusion already suffered by non- English-speaking defendants. These factors make it less likely that justice will be done.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose. To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. Methods. Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. Results. Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. Conclusions. Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Following miniaturisation of cameras and their integration into mobile devices such as smartphones combined with the intensive use of the latter, it is likely that in the near future the majority of digital images will be captured using such devices rather than using dedicated cameras. Since many users decide to keep their photos on their mobile devices, effective methods for managing these image collections are required. Common image browsers prove to be only of limited use, especially for large image sets [1].

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Phonological tasks are highly predictive of reading development but their complexity obscures the underlying mechanisms driving this association. There are three key components hypothesised to drive the relationship between phonological tasks and reading; (a) the linguistic nature of the stimuli, (b) the phonological complexity of the stimuli, and (c) the production of a verbal response. We isolated the contribution of the stimulus and response components separately through the creation of latent variables to represent specially designed tasks that were matched for procedure. These tasks were administered to 570 6 to 7-year-old children along with standardised tests of regular word and non-word reading. A structural equation model, where tasks were grouped according to stimulus, revealed that the linguistic nature and the phonological complexity of the stimulus predicted unique variance in decoding, over and above matched comparison tasks without these components. An alternative model, grouped according to response mode, showed that the production of a verbal response was a unique predictor of decoding beyond matched tasks without a verbal response. In summary, we found that multiple factors contributed to reading development, supporting multivariate models over those that prioritize single factors. More broadly, we demonstrate the value of combining matched task designs with latent variable modelling to deconstruct the components of complex tasks.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Corporate Social Responsibility (CSR) becomes ever more important for organizations. In times of corporate scandals and more governmental regulation on the one hand and a foreseeable shortage of highly qualified employees on the other, CSR is both a means to serve the wider society and to attract employees with a positive reputation and image. The aim of the present study was to determine whether CSR activities as perceived by employees indeed lead to more employee affective commitment and whether this would be moderated by employee differences in importance of CSR. The study differentiated two forms of CSR, namely corporate social responsibility directed towards individual employees (CSR-E) and directed towards the wider society (CSR-S). We surveyed 89 employees and found evidence for the predicted moderation and for both forms of CSR such that CSR-E and CSR-S and affective commitment were only positively related for those employees who evaluated CSR as important. Implications for recruitment and future research are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Some species of crustose lichens, such as Ochrolechia parella (L.) Massal., exhibit concentric marginal rings, which may represent an alternative technique of measuring growth rates and potentially, a new lichenometric dating method. To examine this hypothesis, the agreement and correlation between ring widths and directly measured annual radial growth rates (RaGR, mm a-1) were studied in 24 thalli of O. parella in north Wales, UK, using digital photography and image analysis. Variation in ring width was observed at different locations around a thallus, between thalli, and from year to year. The best agreement and correlation between ring width and lichen growth rates was between mean width of the outer two rings (measured in 2011) and mean RaGR (in 2009/10). The O. parella data suggest that mean width of the youngest two growth rings, averaged over a sample of thalli, is a predictor of recent growth rates and therefore could be used in lichenometry. Potential applications include as a convenient method of comparing lichen growth rates on surfaces in different environmental settings; and as an alternative method of constructing lichen growth-rate curves, without having to revisit the same lichen thalli over many years. However, care is needed when using growth rings to estimate growth rates as: growth ring widths may not be stable; ring widths exhibit spatial and temporal variation; rings may not represent 1-year's growth in all thalli; and adjacent rings may not always represent successive year's growth.