172 resultados para Wolffsohn, DavidWolffsohn, DavidDavidWolffsohn
em Aston University Research Archive
Resumo:
Purpose. To convert objective image analysis of anterior ocular surfaces into recognisable clinical grades, in order to provide a more sensitive and reliable equivalent to current subjective grading methods; a prospective, randomized study correlating clinical grading with digital image assessment. Methods. The possible range of clinical presentations Of bulbar and palpebral hyperaemia, palpebral roughness and corneal staining were represented by 4 sets of 10 images. The images were displayed in random order and graded by 50 clinicians using both subjective CCLRU and Efron grading scales. Previously validated objective image analysis was performed 3 times oil each of the 40 images. Digital measures included edge-detection and relative-coloration components. Step-wise regression analysis determined correlations between the average subjective grade and the objective image analysis measures. Results. Average subjective grades Could be predicted by a combination of the objective image analysis components. These digital ``grades'' accounted for between 69%, (for Efron scale-graded palpebral redness) and 98% (for Efron scale-graded bulbar hyperaemia) of the subjective variance. Conclusions. The results indicate that clinicians may use a combination of vessel areas and overall hue in their judgment of clinical severity for certain conditions. Objective grading call take these aspects into account, and be used to predict an average ``objective grade'' to be used by a clinician in describing the anterior eye. These measures are more sensitive and reliable than subjective grading while still utilizing familiar terminology, and can be applied in research or practice to improve the detection, and monitoring of ocular surface changes.
Resumo:
Background: The MacDQoL is an individualised measure of the impact of macular degeneration (MD) on quality of life (QoL). There is preliminary evidence of its psychometric properties and sensitivity to severity of MD. The aim of this study was to carry out further psychometric evaluation with a larger sample and investigate the measure's sensitivity to MD severity. Methods: Patients with MD (n = 156: 99 women, 57 men, mean age 79 ± 13 years), recruited from eye clinics (one NHS, one private) completed the MacDQoL by telephone interview and later underwent a clinic vision assessment including near and distance visual acuity (VA), comfortable near VA, contrast sensitivity, colour recognition, recovery from glare and presence or absence of distortion or scotoma in the central 10° of the visual field. Results: The completion rate for the MacDQoL items was 99.8%. Of the 26 items, three were dropped from the measure due to redundancy. A fourth was retained in the questionnaire but excluded when computing the scale score. Principal components analysis and Cronbach's alpha (0.944) supported combining the remaining 22 items in a single scale. Lower MacDQoL scores, indicating more negative impact of MD on QoL, were associated with poorer distance VA (better eye r = -0.431 p < 0.001; worse eye r = -0.350 p < 0.001; binocular vision r = -0.419 p < 0.001) and near VA (better eye r -0.326 p < 0.001; worse eye r = -0.226 p < 0.001; binocular vision r = -0.326 p < 0.001). Poorer MacDQoL scores were associated with poorer contrast sensitivity (better eye r = 0.392 p < 0.001; binocular vision r = 0.423 p < 0.001), poorer colour recognition (r = 0.417 p < 0.001) and poorer comfortable near VA (r = -0.283, p < 0.001). The MacDQoL differentiated between those with and without binocular scotoma (U = 1244 p < 0.001). Conclusion: The MacDQoL 22-item scale has excellent internal consistency reliability and a single-factor structure. The measure is acceptable to respondents and the generic QoL item, MD-specific QoL item and average weighted impact score are related to several measures of vision. The MacDQoL demonstrates that MD has considerable negative impact on many aspects of QoL, particularly independence, leisure activities, dealing with personal affairs and mobility. The measure may be valuable for use in clinical trials and routine clinical care. © 2005 Mitchell et al; licensee BioMed Central Ltd.
Resumo:
Purpose. A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry. Methods. Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 ± 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days. Results. Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 ± 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 ± 0.09 mm; vertical: difference, 0.01 ± 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 ± 0.09 mm; vertical: intersession difference, -0.01 ± 0.12 mm). Conclusion. The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.
Resumo:
Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.
Resumo:
The oculomotor synergy as expressed by the CA/C and AC/A ratios was investigated to examine its influence on our previous observation that whereas convergence responses to stereoscopic images are generally stable, some individuals exhibit significant accommodative overshoot. Using a modified video refraction unit while viewing a stereoscopic LCD, accommodative and convergence responses to balanced and unbalanced vergence and focal stimuli (BVFS and UBVFS) were measured. Accommodative overshoot of at least 0.3 D was found in 3 out of 8 subjects for UBVFS. The accommodative response differential (RD) was taken to be the difference between the initial response and the subsequent mean static steady-state response. Without overshoot, RD was quantified by finding the initial response component. A mean RD of 0.11 +/- 0.27 D was found for the 1.0 D step UBVFS condition. The mean RD for the BVFS was 0.00 +/- 0.17 D. There was a significant positive correlation between CA/C ratio and RD (r = +0.75, n = 8, p <0.05) for only UBVFS. We propose that inter-subject variation in RD is influenced by the CA/C ratio as follows: an initial convergence response, induced by disparity of the image, generates convergence-driven accommodation commensurate with the CA/C ratio; the associated transient defocus subsequently decays to a balanced position between defocus-induced and convergence-induced accommodations.
Resumo:
Visual impairment is a large and growing socioeconomic problem. Good evidence on rehabilitation outcomes is required to guide service development and improve the lives of people with sight loss. Of the 478 potentially relevant articles identified, only 58 studies met our liberal inclusion criteria, and of these only 7 were randomized controlled trials. Although the literature is sufficient to confirm that rehabilitation services result in improved clinical and functional ability outcomes, the effects on mood, vision-related quality of life (QoL) and health-related QoL are less clear. There are some good data on the performance of particular types of intervention, but almost no useful data about outcomes in children, those of working age, and other groups. There were no reports on cost effectiveness. Overall, the number of well-designed and adequately reported studies is pitifully small; visual rehabilitation research needs higher quality research. We highlight study design and reporting considerations and suggest a future research agenda.
Resumo:
PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.
Resumo:
Cataract surgery is a technique described since recorded history, yet it has greatly evolved only in the latter half of the past century. The development of the intraocular lens and phacoemulsification as a technique for cataract removal could be considered as the two most significant strides that have been made in this surgical field. This review takes a comprehensive look at all aspects of cataract surgery, starting from patient selection through the process of consent, anaesthesia, biometry, lens power calculation, refractive targeting, phacoemulsification, choice of intraocular lens and management of complications, such as posterior capsular opacification, as well as future developments. As the most common ophthalmic surgery and with the expanding range of intraocular lens options, optometrists have an important and growing role in managing patients with cataract.
Resumo:
PURPOSE: To examine the effect of uncorrected astigmatism in older adults. SETTING: University Vision Clinic METHOD: Twenty-one healthy presbyopes, aged 58.9±2.8 years, had astigmatism of 0.0 to -4.0 x 90?DC and -3.0DC of cylinder at 90?, 180? and 45? induced with spectacle lenses, with the mean spherical equivalent compensated to plano, in random order. Visual acuity was assessed binocularly using a computerised test chart at 95%, 50% and 10% contrast. Near acuity and reading speed were measured using standardised reading texts. Light scatter was quantified with the cQuant and driving reaction times with a computer simulator. Finally visual clarity of a mobile phone and computer screen was subjectively rated. RESULTS: Distance visual acuity decreased with increasing uncorrected astigmatic power (F=174.50, p<0.001) and was reduced at lower contrasts (F=170.77, p<0.001). Near visual acuity and reading speed also decreased with increasing uncorrected astigmatism power (p<0.001). Light scatter was not significantly affected by uncorrected astigmatism (p>0.05), but the reliability and variability of measurements decreased with increasing uncorrected astigmatic power (p<0.05). Driving simulator performance was also unaffected by uncorrected astigmatism (p>0.05), but subjective rating of clarity decreased with increasing uncorrected astigmatic power (p<0.001). Uncorrected astigmatism at 45? or 180? orientation resulted in a worse distance and near visual acuity, and subjective rated clarity than 90? orientation (p<0.05). CONCLUSION: Uncorrected astigmatism, even as low as 1.0DC, causes a significant burden on a patient’s vision. If left uncorrected, this could impact significantly on their independence, quality of life and wellbeing.
Resumo:
Purpose: To determine the critical fitting characteristics of modern soft contact lens fits and from this to devise a simplified recording scheme. Methods: Ten subjects (aged 28.1 ± 7.4 years) wore eight different modern soft contact lenses. Video was captured and analysed of blink (central and up-gaze), excursion lag (up, down, right and left gaze) and push-up movement, centration and coverage. Results: Lens centration was on average close to the corneal centre. Movement on blink was significantly smaller in up-gaze than in primary-gaze (p<0.001). Lag was greatest in down-gaze and least in up-gaze (p<0.001). Push-up test recovery speed was 1.32±0.73mm/s. Overall lens movement was determined best by assessing horizontal lag, movement on blink in up-gaze and push-up recovery speed. Steeper lens base-curves did not have a significant effect on lens fit characteristics. Contact lens material did influence lens fit characteristics, particularly silicone-hydrogels which generally had lower centration and a faster push-up speed of recovery than HEMA lenses (p<0.05). Conclusion: Lag on vertical gaze, and movement on blink in primary gaze generally provide little extra information on overall lens movement compared to horizontal lag, movement on blink in up gaze and push-up recovery speed. They can therefore be excluded from a simplified recording scheme. A simplified and comprehensive soft contact lens fit recording system could consist of a cross-hairs indicating the centre of the cornea; a circle to indicate the lens centration; a mark on the relevant position of the circle to indicate any limbal incursion; a grade (‘B’) below for movement with blink in up-gaze, a grade (‘L’) to the side for horizontal lag and a grade above (‘P’) for the assessed push-up recovery speed.
Resumo:
To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit.
Resumo:
Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was
Resumo:
The correction of presbyopia and restoration of true accommodative function to the ageing eye is the focus of much ongoing research and clinical work. A range of accommodating intraocular lenses (AIOLs) implanted during cataract surgery has been developed and they are designed to change either their position or shape in response to ciliary muscle contraction to generate an increase in dioptric power. Two main design concepts exist. First, axial shift concepts rely on anterior axial movement of one or two optics creating accommodative ability. Second, curvature change designs are designed to provide significant amplitudes of accommodation with little physical displacement. Single-optic devices have been used most widely, although the true accommodative ability provided by forward shift of the optic appears limited and recent findings indicate that alternative factors such as flexing of the optic to alter ocular aberrations may be responsible for the enhanced near vision reported in published studies. Techniques for analysing the performance of AIOLs have not been standardised and clinical studies have reported findings using a wide range of both subjective and objective methods, making it difficult to gauge the success of these implants. There is a need for longitudinal studies using objective methods to assess long-term performance of AIOLs and to determine if true accommodation is restored by the designs available. While dual-optic and curvature change IOLs are designed to provide greater amplitudes of accommodation than is possible with single-optic devices, several of these implants are in the early stages of development and require significant further work before human use is possible. A number of challenges remain and must be addressed before the ultimate goal of restoring youthful levels of accommodation to the presbyopic eye can be achieved.
Resumo:
Allergic eye disease encompasses a group of hypersensitivity disorders which primarily affect the conjunctiva and its prevalence is increasing. It is estimated to affect 8% of patients attending optometric practice but is poorly managed and rarely involves ophthalmic assessment. Seasonal allergic conjunctivitis (SAC) is the most common form of allergic eye disease (90%), followed by perennial allergic conjunctivitis (PAC; 5%). Both are type 1 IgE mediated hypersensitivity reactions where mast cells play an important role in pathophysiology. The signs and symptoms are similar but SAC occurs periodically whereas PAC occurs year round. Despite being a relatively mild condition, the effects on the quality of life can be profound and therefore they demand attention. Primary management of SAC and PAC involves avoidance strategies depending on the responsible allergen(s) to prevent the hypersensitivity reaction. Cooled tear supplements and cold compresses may help bring relief. Pharmacological agents may become necessary as it is not possible to completely avoid the allergen(s). There are a wide range of anti-allergic medications available, such as mast cell stabilisers, antihistamines and dual-action agents. Severe cases refractory to conventional treatment require anti-inflammatories, immunomodulators or immunotherapy. Additional qualifications are required to gain access to these medications, but entry-level optometrists must offer advice and supportive therapy. Based on current evidence, the efficacy of anti-allergic medications appears equivocal so prescribing should relate to patient preference, dosing and cost. More studies with standardised methodologies are necessary elicit the most effective anti-allergic medications but those with dual-actions are likely to be first line agents.
Resumo:
Aim: To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. Methods: EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) years). Measurements were made on two occasions separated by 1 year. Intrasession repeatability was assessed by repeating the measures after a 10 minute recovery period at the first visit. Distance visual acuity was measured with a logMAR chart, near visual acuity with a MNRead chart at 25 cm, contrast sensitivity with a Pelli-Robson chart, and the presence of central visual disturbance assessed with an Amsler grid. A questionnaire was used to assess self reported difficulties with glare recovery. Results: The average EMS recovery time was 11.0 (SD 8.9) seconds, decreasing by 1.6 (5.2) seconds on repeated measurement (p<0.05). EMS photostress recovery was not correlated with visual function measures or subjective difficulties with lights (p>0.05). EMS photostress recovery time did not predict those whose vision decreased over the following year compared with those among whom it remained stable. Conclusions: The EMS test is not a useful tool in determining the severity or progression of AMD.