3 resultados para Wills Hospital for the Relief of the Indigent Blind and Lame, Philadelphia.

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of Diagnosis Related Groups (DRG) as a mechanism for hospital financing is a currently debated topic in Portugal. The DRG system was scheduled to be initiated by the Health Ministry of Portugal on January 1, 1990 as an instrument for the allocation of public hospital budgets funded by the National Health Service (NHS), and as a method of payment for other third party payers (e.g., Public Employees (ADSE), private insurers, etc.). Based on experience from other countries such as the United States, it was expected that implementation of this system would result in more efficient hospital resource utilisation and a more equitable distribution of hospital budgets. However, in order to minimise the potentially adverse financial impact on hospitals, the Portuguese Health Ministry decided to gradually phase in the use of the DRG system for budget allocation by using blended hospitalspecific and national DRG casemix rates. Since implementation in 1990, the percentage of each hospitals budget based on hospital specific costs was to decrease, while the percentage based on DRG casemix was to increase. This was scheduled to continue until 1995 when the plan called for allocating yearly budgets on a 50% national and 50% hospitalspecific cost basis. While all other nonNHS third party payers are currently paying based on DRGs, the adoption of DRG casemix as a National Health Service budget setting tool has been slower than anticipated. There is now some argument in both the political and academic communities as to the appropriateness of DRGs as a budget setting criterion as well as to their impact on hospital efficiency in Portugal. This paper uses a twostage procedure to assess the impact of actual DRG payment on the productivity (through its components, i.e., technological change and technical efficiency change) of diagnostic technology in Portuguese hospitals during the years 1992–1994, using both parametric and nonparametric frontier models. We find evidence that the DRG payment system does appear to have had a positive impact on productivity and technical efficiency of some commonly employed diagnostic technologies in Portugal during this time span.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Adverse drug reactions (ADRs) cause significant morbidity and mortality and account for around 6.5% of hospital admissions. Patient experiences of serious ADRs and their long-term impact on patients' lives, including their influence on current attitudes towards medicines, have not been previously explored. Objective: The aim of the study was to explore the experiences, beliefs, and attitudes of survivors of serious ADRs, using drug-induced Stevens-Johnson syndrome (SJS) and Toxic Epidermal Necrolysis (TEN) as a paradigm. Methods: A retrospective, qualitative study was undertaken using detailed semi-structured interviews. Fourteen adult survivors of SJS and TEN, admitted to two teaching hospitals in the UK, one the location of a tertiary burns centre, were interviewed. Interview transcripts were independently analysed by three different researchers and themes emerging from the text identified. Results: All 14 patients were aware that their condition was drug induced, and all but one knew the specific drug(s) implicated. Several expressed surprise at the perceived lack of awareness of the ADR amongst healthcare professionals, and described how the ADR was mistaken for another condition. Survivors believed that causes of the ADR included (i) being given too high a dose of the drug; (ii) medical staff ignoring existing allergies; and (iii) failure to monitor blood tests. Only two believed that the reaction was unavoidable. Those who believed that the condition could have been avoided had less trust in healthcare professionals. The ADR had a persisting impact on their current lives physically and psychologically. Many now avoided medicines altogether and were fearful of becoming ill enough to need them. © 2011 Adis Data Information BV. All rights reserved. Conclusions: Life-threatening ADRs continued to affect patients’ lives long after the event. Patients’ beliefs regarding the cause of the ADR differed, and may have influenced their trust in healthcare professionals and medicines. We propose that clear communication during the acute phase of a serious ADR may therefore be important.