3 resultados para Water-table

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A study of information available on the settlement characteristics of backfill in restored opencast coal mining sites and other similar earthworks projects has been undertaken. In addition, the methods of opencast mining, compaction controls, monitoring and test methods have been reviewed. To consider and develop the methods of predicting the settlement of fill, three sites in the West Midlands have been examined; at each, the backfill had been placed in a controlled manner. In addition, use has been made of a finite element computer program to compare a simple two-dimensional linear elastic analysis with field observations of surface settlements in the vicinity of buried highwalls. On controlled backfill sites, settlement predictions have been accurately made, based on a linear relationship between settlement (expressed as a percentage of fill height) against logarithm of time. This `creep' settlement was found to be effectively complete within 18 months of restoration. A decrease of this percentage settlement was observed with increasing fill thickness; this is believed to be related to the speed with which the backfill is placed. A rising water table within the backfill is indicated to cause additional gradual settlement. A prediction method, based on settlement monitoring, has been developed and used to determine the pattern of settlement across highwalls and buried highwalls. The zone of appreciable differential settlement was found to be mainly limited to the highwall area, the magnitude was dictated by the highwall inclination. With a backfill cover of about 15 metres over a buried highwall the magnitude of differential settlement was negligible. Use has been made of the proposed settlement prediction method and monitoring to control the re-development of restored opencase sites. The specifications, tests and monitoring techniques developed in recent years have been used to aid this. Such techniques have been valuable in restoring land previously derelict due to past underground mining.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Horizontal Subsurface Flow Treatment Wetlands (HSSF TWs) are used by Severn Trent Water as a low-cost tertiary wastewater treatment for rural locations. Experience has shown that clogging is a major operational problem that reduces HSSF TW lifetime. Clogging is caused by an accumulation of secondary wastewater solids from upstream processes and decomposing leaf litter. Clogging occurs as a sludge layer where wastewater is loaded on the surface of the bed at the inlet. Severn Trent systems receive relatively high hydraulic loading rates, which causes overland flow and reduces the ability to mineralise surface sludge accumulations. A novel apparatus and method, the Aston Permeameter, was created to measure hydraulic conductivity in situ. Accuracy is ±30 %, which was considered adequate given that conductivity in clogged systems varies by several orders of magnitude. The Aston Permeameter was used to perform 20 separate tests on 13 different HSSF TWs in the UK and the US. The minimum conductivity measured was 0.03 m/d at Fenny Compton (compared with 5,000 m/d clean conductivity), which was caused by an accumulation of construction fines in one part of the bed. Most systems displayed a 2 to 3 order of magnitude variation in conductivity in each dimension. Statistically significant transverse variations in conductivity were found in 70% of the systems. Clogging at the inlet and outlet was generally highest where flow enters the influent distribution and exits the effluent collection system, respectively. Surface conductivity was lower in systems with dense vegetation because plant canopies reduce surface evapotranspiration and decelerate sludge mineralisation. An equation was derived to describe how the water table profile is influenced by overland flow, spatial variations in conductivity and clogging. The equation is calibrated using a single parameter, the Clog Factor (CF), which represents the equivalent loss of porosity that would reproduce measured conductivity according to the Kozeny-Carman Equation. The CF varies from 0 for ideal conditions to 1 for completely clogged conditions. Minimum CF was 0.54 for a system that had recently been refurbished, which represents the deviation from ideal conditions due to characteristics of non-ideal media such as particle size distribution and morphology. Maximum CF was 0.90 for a 15 year old system that exhibited sludge accumulation and overland flow across the majority of the bed. A Finite Element Model of a 15 m long HSSF TW was used to indicate how hydraulics and hydrodynamics vary as CF increases. It was found that as CF increases from 0.55 to 0.65 the subsurface wetted area increases, which causes mean hydraulic residence time to increase from 0.16 days to 0.18 days. As CF increases from 0.65 to 0.90, the extent of overland flow increases from 1.8 m to 13.1 m, which reduces hydraulic efficiency from 37 % to 12 % and reduces mean residence time to 0.08 days.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Finite Element Analysis (FEA) model is used to explore the relationship between clogging and hydraulics that occurs in Horizontal Subsurface Flow Treatment Wetlands (HSSF TWs) in the United Kingdom (UK). Clogging is assumed to be caused by particle transport and an existing single collector efficiency model is implemented to describe this behaviour. The flow model was validated against HSSF TW survey results obtained from the literature. The model successfully simulated the influence of overland flow on hydrodynamics, and the interaction between vertical flow through the low permeability surface layer and the horizontal flow of the saturated water table. The clogging model described the development of clogging within the system but under-predicted the extent of clogging which occurred over 15 years. This is because important clogging mechanisms were not considered by the model, such as biomass growth and vegetation establishment. The model showed the usefulness of FEA for linking hydraulic and clogging phenomenon in HSSF TWs and could be extended to include treatment processes. © 2011 Springer Science+Business Media B.V.