9 resultados para W. and A. Gilbey, Ltd.

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Juridical Review. Looks at the question of whether an individual shareholder has title to bring an action on the company's behalf in exceptional circumstances, as considered in the cases of Anderson v Hogg and Wilson v Inverness Retail & Business Park Ltd. Examines the difference between English and Scottish law in this area, notwithstanding the reliance on English case law in Scotland due to the small number of Scottish cases decided. Looks at progress towards the reform of company law and the impact it will have on a shareholder's title to sue.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Case law report - online

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To introduce a new technique for co-registration of Magnetoencephalography (MEG) with magnetic resonance imaging (MRI). We compare the accuracy of a new bite-bar with fixed fiducials to a previous technique whereby fiducial coils were attached proximal to landmarks on the skull. Methods: A bite-bar with fixed fiducial coils is used to determine the position of the head in the MEG co-ordinate system. Co-registration is performed by a surface-matching technique. The advantage of fixing the coils is that the co-ordinate system is not based upon arbitrary and operator dependent fiducial points that are attached to landmarks (e.g. nasion and the preauricular points), but rather on those that are permanently fixed in relation to the skull. Results: As a consequence of minimizing coil movement during digitization, errors in localization of the coils are significantly reduced, as shown by a randomization test. Displacement of the bite-bar caused by removal and repositioning between MEG recordings is minimal (∼0.5 mm), and dipole localization accuracy of a somatosensory mapping paradigm shows a repeatability of ∼5 mm. The overall accuracy of the new procedure is greatly improved compared to the previous technique. Conclusions: The test-retest reliability and accuracy of target localization with the new design is superior to techniques that incorporate anatomical-based fiducial points or coils placed on the circumference of the head. © 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sixty coagulase-negative staphylococcus (CNS) isolates were recovered from the blood cultures or peritoneal dialysate effluent of 43 patients on renal dialysis. The patients had either renal dialysis catheter-related sepsis (CRS) or continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis. Isolates were characterized by biotyping, and genotyped by pulsed-field gel electrophoresis (PFGE). Phenotypic properties of the strains were also investigated. Several genotypes were identified with no one specific strain of CNS being associated with CRS. However, closely related strains were isolated from several patients within the units studied, suggesting horizontal transfer of micro-organisms. Genotypic macro-restriction profiles did not concur with phenotypic profiles or biotypes, confirming that genotyping is required for epidemiological studies. All staphylococcal strains were investigated for the production of phenotypic characteristics. Significant differences were predominantly seen in the production of lipase, esterase and elastase in strains isolated from the renal patients with CRS and CAPD-associated peritonitis, compared with a non-septic control group. These phenotypic characteristics may therefore have a role in the maintenance of CRS in renal patients. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last fifteen years Alzheimer's disease (AD) has changed the way in which developed countries have tended to perceive and deal with ageing. It has also become the main health problem needing to be resolved in both financial and social terms. If cancer was considered and labelled as the epidemic of the twentieth century, AD has soon been designated as the epidemic of the twenty-first century. This article analyses how AD is perceived and represented in two films, Amanecer de un sueño, directed in 2008 by Freddy Mas Franqueza, and ¿Y tú quién eres?, directed in 2007 by Antonio Mercero. As for ageing, questions of stigmatization and stereotyping around AD are discussed, and special consideration is given to the manner in which medical, social and political institutions in Spain have created a monolithic view of AD with the purpose of shaping a homogeneous social response to the disease. Current debates between those who perceive the disease as a social burden for the State and the family, and those who defend centring the discussion on the persons diagnosed with Alzheimer's disease and their personhoods frame the analysis of these two films. © W. S. Maney & Son Ltd 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We experimentally study the generation and amplification of stable picosecond-short optical pulses by a master oscillator power-amplifier configuration consisting of a monolithic quantum-dot-based gain-guided tapered laser and amplifier emitting at 1.26 μm without pulse compression, external cavity, gain-or Q-switched operation. We report a peak power of 42 W and a figure-of-merit for second-order nonlinear imaging of 38.5 W2 at a repetition rate of 16 GHz and an associated pulse width of 1.37 ps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cochleostomy formation is a key stage of the cochlear implantation procedure. Minimizing the trauma sustained by the cochlea during this step is thought to be a critical feature in hearing preservation cochlear implantation. The aim of this paper is firstly, to assess the cochlea disturbances during manual and robotic cochleostomy formation. Secondly, to determine whether the use of a smart micro-drill is feasible during human cochlear implantation. Materials and methods: The disturbances within the cochlea during cochleostomy formation were analysed in a porcine specimen by creating a third window cochleostomy, preserving the underlying endosteal membrane, on the anterior aspect of the basal turn of the cochlea. A laser vibrometer was aimed at this third window, to assess its movement while a traditional cochleostomy was performed. Six cochleostomies were performed in total, three manually and three with a smart micro-drill. The mean and peak membrane movement was calculated for both manual and smart micro-drill arms, to represent the disturbances sustained within cochlea during cochleostomy formation. The smart micro-drill was further used to perform live human robotic cochleostomies on three adult patients who met the National Institute of Health and Clinical Excellence criteria for undergoing cochlear implantation. Results: In the porcine trial, the smart micro-drill preserved the endosteal membrane in all three cases. The velocity of movement of the endosteal membrane during manual cochleostomy is approximately 20 times higher on average and 100 times greater in peak velocity, than for robotic cochleostomy. The robot was safely utilized in theatre in all three cases and successfully created a bony cochleostomy while preserving the underlying endosteal membrane. Conclusions: Our experiments have revealed that controlling the force of drilling during cochleostomy formation and opening the endosteal membrane with a pick will minimize the trauma sustained by the cochlea by a factor of 20. Additionally, the smart micro-drill can safely perform a bony cochleostomy in humans under operative conditions and preserve the integrity of the underlying endosteal membrane. © W. S. Maney & Son Ltd 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Constant load, progressive load and multipass nanoscratch (nanowear) tests were carried out on 500 and 1500 nm TiN coatings on M42 steel chosen as model systems. The influences of film thickness, coating roughness, scratch direction relative to the grinding grooves on the critical load in the progressive load test and number of cycles to failure in the wear test have been determined. Progress towards the development of a suitable methodology for determining the scratch hardness from nanoscratch tests is discussed. © 2011 W. S. Maney & Son Ltd.