Resumo:
Background/aims: Network 1000 is a UK-based panel survey of a representative sample of adults with registered visual impairment, with the aim of gathering information about people’s opinions and circumstances. Method: Participants were interviewed (Survey 1, n = 1007: 2005; Survey 2, n = 922: 2006/07) on a range of topics including the nature of their eye condition, details of other health issues, use of low vision aids (LVAs) and their experiences in eye clinics. Results: Eleven percent of individuals did not know the name of their eye condition. Seventy percent of participants reported having long-term health problems or disabilities in addition to visual impairment and 43% reported having hearing difficulties. Seventy one percent reported using LVAs for reading tasks. Participants who had become registered as visually impaired in the previous 8 years (n = 395) were asked questions about non-medical information received in the eye clinic around that time. Reported information received included advice about ‘registration’ (48%), low vision aids (45%) and social care routes (43%); 17% reported receiving no information. While 70% of people were satisfied with the information received, this was lower for those of working age (56%) compared with retirement age (72%). Those who recalled receiving additional non-medical information and advice at the time of registration also recalled their experiences more positively. Conclusions: Whilst caution should be applied to the accuracy of recall of past events, the data provide a valuable insight into the types of information and support that visually impaired people feel they would benefit from in the eye clinic.
Resumo:
Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.
Resumo:
Aim: Contrast sensitivity (CS) provides important information on visual function. This study aimed to assess differences in clinical expediency of the CS increment-matched new back-lit and original paper versions of the Melbourne Edge Test (MET) to determine the CS of the visually impaired. Methods: The back-lit and paper MET were administered to 75 visually impaired subjects (28-97 years). Two versions of the back-lit MET acetates were used to match the CS increments with the paper-based MET. Measures of CS were repeated after 30 min and again in the presence of a focal light source directed onto the MET. Visual acuity was measured with a Bailey-Lovie chart and subjects rated how much difficulty they had with face and vehicle recognition. Results: The back-lit MET gave a significantly higher CS than the paper-based version (14.2 ± 4.1 dB vs 11.3 ± 4.3 dB, p < 0.001). A significantly higher reading resulted with repetition of the paper-based MET (by 1.0 ± 1.7 dB, p < 0.001), but this was not evident with the back-lit MET (by 0.1 ± 1.4 dB, p = 0.53). The MET readings were increased by a focal light source, in both the back-lit (by 0.3 ± 0.81, p < 0.01) and paper-based (1.2 ± 1.7, p < 0.001) versions. CS as measured by the back-lit and paper-based versions of the MET was significantly correlated to patients' perceived ability to recognise faces (r = 0.71, r = 0.85 respectively; p < 0.001) and vehicles (r = 0.67, r = 0.82 respectively; p < 0.001), and with distance visual acuity (both r =-0.64; p < 0.001). Conclusions: The CS increment-matched back-lit MET gives higher CS values than the old paper-based test by approximately 3 dB and is more repeatable and less affected by external light sources. Clinically, the MET score provides information on patient difficulties with visual tasks, such as recognising faces. © 2005 The College of Optometrists.
Resumo:
Purpose: To examine the use of real-time, generic edge detection, image processing techniques to enhance the television viewing of the visually impaired. Design: Prospective, clinical experimental study. Method: One hundred and two sequential visually impaired (average age 73.8 ± 14.8 years; 59% female) in a single center optimized a dynamic television image with respect to edge detection filter (Prewitt, Sobel, or the two combined), color (red, green, blue, or white), and intensity (one to 15 times) of the overlaid edges. They then rated the original television footage compared with a black-and-white image displaying the edges detected and the original television image with the detected edges overlaid in the chosen color and at the intensity selected. Footage of news, an advertisement, and the end of program credits were subjectively assessed in a random order. Results: A Prewitt filter was preferred (44%) compared with the Sobel filter (27%) or a combination of the two (28%). Green and white were equally popular for displaying the detected edges (32%), with blue (22%) and red (14%) less so. The average preferred edge intensity was 3.5 ± 1.7 times. The image-enhanced television was significantly preferred to the original (P < .001), which in turn was preferred to viewing the detected edges alone (P < .001) for each of the footage clips. Preference was not dependent on the condition causing visual impairment. Seventy percent were definitely willing to buy a set-top box that could achieve these effects for a reasonable price. Conclusions: Simple generic edge detection image enhancement options can be performed on television in real-time and significantly enhance the viewing of the visually impaired. © 2007 Elsevier Inc. All rights reserved.
Resumo:
Background: Prescribing magnification is typically based on distance or near visual acuity. this presumes a constant minimum angle of visual resolution with working distance and therefore enlargement of an object moved to a shorter working distance (relative distance enlargement). this study examines this premise in a visually impaired population. methods: distance letter visual acuity was measured prospectively for 380 low vision patients (distance visual acuity between 0.3 and 2.1 logmar) over the age of 57 years, along with near word visual acuity at an appropriate distance for near lens additions from +4 d to +20 D. demographic information, the disease causing low vision, contrast sensitivity, visual field and psychological status were also recorded. results: distance letter acuity was significantly related to (r = 0.84) but on average 0.1 ± 0.2 logmar better (1 ± 2 lines on a logmar chart) than near word acuity at 25 cm with a +4 d lens addition. in 39. 8 per cent of patients, near word acuity was more than 0.1 logmar worse than distance letter acuity. in 11.0 per cent of subjects, near visual acuity was more than 0.1 logmar better than distance letter acuity. the group with near word acuity worse than distance letter acuity also had lower contrast sensitivity. the group with near word acuity better than distance letter acuity was less likely to have age-Related macular degeneration. smaller print size could be read by reducing working distance (achieved by using higher near lens additions) in 86. 1 per cent, although not by as much as predicted by geometric progression in 14. 5 per cent. discussion: although distance letter and near word acuity are highly related, they are on average 1 logmar line different and this varies significantly between individuals. near word acuity did not increase linearly with relative distance enlargement in approximately one in seven visually impaired, suggesting that the measurement of visual resolution over a range of working distances will assist appropriate prescribing of magnification aids.
Resumo:
AIM To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. METHODS Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual im pairm ent. RESULTS Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. CONCLUSION The faVIQ allows sensitive assessm ent of quality-of-life in the visually im paired and should support studies which evaluate the effectiveness of low vision rehabilitation services. © Copyright International Journal of Ophthalmology Press.
Resumo:
Magnification can be provided to assist those with visual impairment to make the best use of remaining vision. Electronic transverse magnification of an object was first conceived for use in low vision in the late 1950s, but has developed slowly and is not extensively prescribed because of its relatively high cost and lack of portability. Electronic devices providing transverse magnification have been termed closed-circuit televisions (CCTVs) because of the direct cable link between the camera imaging system and monitor viewing system, but this description generally refers to surveillance devices and does not indicate the provision of features such as magnification and contrast enhancement. Therefore, the term Electronic Vision Enhancement Systems (EVES) is proposed to better distinguish and describe such devices. This paper reviews current knowledge on EVES for the visually impaired in terms of: classification; hardware and software (development of technology, magnification and field-of-view, contrast and image enhancement); user aspects (users and usage, reading speed and duration, and training); and potential future development of EVES. © 2003 The College of Optometrists.
Resumo:
PURPOSE: To examine whether objective performance of near tasks is improved with various electronic vision enhancement systems (EVES) compared with the subject's own optical magnifier. DESIGN: Experimental study, randomized, within-patient design. METHODS: This was a prospective study, conducted in a hospital ophthalmology low-vision clinic. The patient population comprised 70 sequential visually impaired subjects. The magnifying devices examined were: patient's optimum optical magnifier; magnification and field-of-view matched mouse EVES with monitor or head-mounted display (HMD) viewing; and stand EVES with monitor viewing. The tasks performed were: reading speed and acuity; time taken to track from one column of print to the next; follow a route map, and locate a specific feature; and identification of specific information from a medicine label. RESULTS: Mouse EVES with HMD viewing caused lower reading speeds than stand EVES with monitor viewing (F = 38.7, P < .001). Reading with the optical magnifier was slower than with the mouse or stand EVES with monitor viewing at smaller print sizes (P < .05). The column location task was faster with the optical magnifier than with any of the EVES (F = 10.3, P < .001). The map tracking and medicine label identification task was slower with the mouse EVES with HMD viewing than with the other magnifiers (P < .01). Previous EVES experience had no effect on task performance (P > .05), but subjects with previous optical magnifier experience were significantly slower at performing the medicine label identification task with all of the EVES (P < .05). CONCLUSIONS: Although EVES provide objective benefits to the visually impaired in reading speed and acuity, together with some specific near tasks, some can be performed just as fast using optical magnification. © 2003 by Elsevier Inc. All rights reserved.
Resumo:
There are around 285 million visually impaired people worldwide, and around 370,000 people are registered as blind or partially sighted in the UK. Ongoing advances in information technology (IT) are increasing the scope for IT-based mobile assistive technologies to facilitate the independence, safety, and improved quality of life of the visually impaired. Research is being directed at making mobile phones and other handheld devices accessible via our haptic (touch) and audio sensory channels. We review research and innovation within the field of mobile assistive technology for the visually impaired and, in so doing, highlight the need for successful collaboration between clinical expertise, computer science, and domain users to realize fully the potential benefits of such technologies. We initially reflect on research that has been conducted to make mobile phones more accessible to people with vision loss. We then discuss innovative assistive applications designed for the visually impaired that are either delivered via mainstream devices and can be used while in motion (e.g., mobile phones) or are embedded within an environment that may be in motion (e.g., public transport) or within which the user may be in motion (e.g., smart homes). © 2013 Elsevier Inc.
Resumo:
PURPOSE: To design and validate a vision-specific quality-of-life assessment tool to be used in a clinical setting to evaluate low-vision rehabilitation strategy and management. METHODS: Previous vision-related questionnaires were assessed by low-vision rehabilitation professionals and patients for relevance and coverage. The 74 items selected were pretested to ensure correct interpretation. One hundred and fifty patients with low vision completed the chosen questions on four occasions to allow the selection of the most appropriate items. The vision-specific quality of life of patients with low vision was compared with that of 70 age-matched and gender-matched patients with normal vision and before and after low-vision rehabilitation in 278 patients. RESULTS: Items that were unreliable, internally inconsistent, redundant, or not relevant were excluded, resulting in the 25-item Low Vision Quality-of-Life Questionnaire (LVQOL). Completion of the LVQOL results in a summed score between 0 (a low quality of life) and 125 (a high quality of life). The LVQOL has a high internal consistency (α = 0.88) and good reliability (0.72). The average LVQOL score for a population with low vision (60.9 ± 25.1) was significantly lower than the average score of those with normal vision (100.3 ± 20.8). Rehabilitation improved the LVQOL score of those with low vision by an average of 6.8 ± 15.6 (17%). CONCLUSIONS: The LVQOL was shown to be an internally consistent, reliable, and fast method for measuring the vision-specific quality of life of the visually impaired in a clinical setting. It is able to quantify the quality of life of those with low vision and is useful in determining the effects of low-vision rehabilitation. Copyright (C) 2000 Elsevier Science Inc.
Resumo:
Aim: To determine the best method of estimating the optimum magnification needed by visually impaired patients. Methods: The magnification of low vision aids prescribed to 187 presbyopic visually impaired patients for reading newspapers or books was compared with logMAR distance and near acuity (at 25 cm) and magnification predicted by +4 D step near additions. Results: Distance letter (r = 0.58) and near word visual acuity (r = 0.67) were strongly correlated to the prescribed magnification as were predictive formulae based on these measures. Prediction using the effect of proximal magnification resulted in a similar correlation (r = 0.67) and prediction was poorer in those who did not benefit from proximal magnification. The difference between prescribed and predicted magnification was found to be unrelated to the condition causing visual impairment (F = 2.57, p = 0.08), the central visual field status (F = 0.57, p = 0.57) and patient psychology (F = 0.44, p = 0.51), but was higher in those prescribed stand magnifiers than high near additions (F = 5.99, p < 0.01). Conclusions: The magnification necessary to perform normal visual tasks can be predicted in the majority of cases using visual acuity measures, although measuring the effect of proximal magnification demonstrates the effect of stronger glasses and identifies those in whom prescribed magnification is more difficult to predict.
Resumo:
Background/Aims: To develop and assess the psychometric validity of a Chinese language Vision Health related quality-of-life (VRQoL) measurement instrument for the Chinese visually impaired. Methods: The Low Vision Quality of Life Questionnaire (LVQOL) was translated and adapted into the Chinese-version Low Vision Quality of Life Questionnaire (CLVQOL). The CLVQOL was completed by 100 randomly selected people with low vision (primary group) and 100 people with normal vision (control group). Ninety-four participants from the primary group completed the CLVQOL a second time 2 weeks later (test-retest group). The internal consistency reliability, test-retest reliability, item-internal consistency, item-discrimination validity, construct validity and discriminatory power of the CLVQOL were calculated. Results: The review committee agreed that the CLVQOL replicated the meaning of the LVQOL and was sensitive to cultural differences. The Cronbach's α coefficient and the split-half coefficient for the four scales and total CLVQOL scales were 0.75-0.97. The test-retest reliability as estimated by the intraclass correlations coefficient was 0.69-0.95. Item-internal consistency was >0.4 and item-discrimination validity was generally <0.40. The Varimax rotation factor analysis of the CLVQOL identified four principal factors. the quality-of-life rating of four subscales and the total score of the CLVQOL of the primary group were lower than those of the Control group, both in hospital-based subjects and community-based subjects. Conclusion: The CLVQOL Chinese is a culturally specific vision-related quality-of-life measure instrument. It satisfies conventional psychometric criteria, discriminates visually healthy populations from low vision patients and may be valuable in screening the local community as well as for use in clinical practice or research. © Springer 2005.
Resumo:
Age-related macular degeneration (AMD) is the leading cause of visual impairment in older adults in the United Kingdom. This study sought to characterise AMD patients who seek the services of the Macular Society, and determine the level and source of their dietary knowledge. A questionnaire was designed, validated, and administered to 158 participants. The questions covered demographic data and knowledge of nutrition and supplementation. The mean age of participants was 79 years; 61% of them were female, and 27% were registered visually impaired. Only 55% of the participants thought diet was important for eye health, 63% felt that they had not received enough information about AMD. The participants reported that their information mainly came from non-professional support groups. Most participants identified healthy food, but could not say why, and were not able to identify carotenoid rich foods. The results of the study will inform design of education and dissemination methods regarding dietary information. © The Author(s) 2014.
Resumo:
Heterotropic association of tissue transglutaminase (TG2) with extracellular matrix-associated fibronectin (FN) can restore the adhesion of fibroblasts when the integrin-mediated direct binding to FN is impaired using RGD-containing peptide. We demonstrate that the compensatory effect of the TG-FN complex in the presence of RGD-containing peptides is mediated by TG2 binding to the heparan sulfate chains of the syndecan-4 cell surface receptor. This binding mediates activation of protein kinase Ca (PKCa) and its subsequent interaction with ß1 integrin since disruption of PKCa binding to ß1 integrins with a cell-permeant competitive peptide inhibits cell adhesion and the associated actin stress fiber formation. Cell signaling by this process leads to the activation of focal adhesion kinase and ERK1/2 mitogen-activated protein kinases. Fibroblasts deficient in Raf-1 do not respond fully to the TG-FN complex unless either the full-length kinase competent Raf-1 or the kinase-inactive domain of Raf-1 is reintroduced, indicating the involvement of the Raf-1 protein in the signaling mechanism. We propose a model for a novel RGD-independent cell adhesion process that could be important during tissue injury and/or remodeling whereby TG-FN binding to syndecan-4 activates PKCa leading to its association with ß1 integrin, reinforcement of actin-stress fiber organization, and MAPK pathway activation.
Resumo:
Background: Developmental dyslexia is typically defined by deficits in phonological skills, but it is also associated with anomalous performance on measures of balance. Although balance assessments are included in several screening batteries for dyslexia, the association between impairments in literacy and deficits in postural stability could be due to the high co-occurrence of dyslexia with other developmental disorders in which impairments of motor behaviour are also prevalent. Methods: We identified 17 published studies that compared balance function between dyslexia and control samples and obtained effect-sizes for each. Contrast and association analyses were used to quantify the influence of hypothesised moderator variables on differences in effects across studies. Results: The mean effect-size of the balance deficit in dyslexia was .64 (95% CI = .44-.78) with heterogeneous findings across the population of studies. Probable co-occurrence of other developmental disorders and variability in intelligence scores in the dyslexia samples were the strongest moderator variables of effect-size. Conclusions: Balance deficits are associated with dyslexia, but these effects are apparently more strongly related to third variables other than to reading ability. Deficits of balance may indicate increased risk of developmental disorder, but are unlikely to be uniquely associated with dyslexia.