4 resultados para Velocity measurement
em Aston University Research Archive
Resumo:
A procedure has been developed which measures the settling velocity distribution of particles within a complete sewage sample. The development of the test method included observations of particle and liquid interaction using both synthetic media and sewage. Comparison studies with two other currently used settling velocity test procedures was undertaken. The method is suitable for use with either DWF or storm sewage. Information relating to the catchment characteristics of 35 No. wastewater treatment works was collected from the privatised water companies in England and Wales. 29 No. of these sites were used in an experimental programme to determine the settling velocity grading of 33 No. sewage samples. The collected data were analysed in an attempt to relate the settling velocity distribution to the characteristics of the contributing catchment. Statistical analysis of the catchment data and the measured settling velocity distributions was undertaken. A curve fitting exercise using an S-shaped curve which had the same physical characteristics as the settling velocity distributions was performed. None of these analyses found evidence that the settling velocity distribution of sewage had a significant relationship with the chosen catchment characteristics. The regression equations produced from the statistical analysis cannot be used to assist in the design of separation devices. However, a grading curve envelope was produced, the limits of which were clearly defined for the measured data set. There was no evidence of a relationship between settling velocity grading and the characteristics of the contributing catchment, particularly the catchment area. The present empirical approach to settling tank design cannot be improved upon at present by considering the variation in catchment parameters. This study has provided a basis for future research into the settling velocity measurement and should be of benefit to future workers within this field.
Resumo:
Off-highway motive plant equipment is costly in capital outlay and maintenance. To reduce these overheads and increase site safety and workrate, a technique of assessing and limiting the velocity of such equipment is required. Due to the extreme environmental conditions met on such sites, conventional velocity measurement techniques are inappropriate. Ogden Electronics Limited were formed specifically to manufacture a motive plant safety system incorporating a speed sensor and sanction unit; to date, the only such commercial unit available. However, problems plague the reliability, accuracy and mass production of this unit. This project assesses the company's exisiting product, and in conjunction with an appreciation of the company history and structure, concludes that this unit is unsuited to its intended application. Means of improving the measurement accuracy and longevity of this unit, commensurate with the company's limited resources and experience, are proposed, both for immediate retrofit and for longer term use. This information is presented in the form of a number of internal reports for the company. The off-highway environment is examined; and in conjunction with an evaluation of means of obtaining a returned signal, comparisons of processing techniques, and on-site gathering of previously unavailable data, preliminary designs for an alternative product are drafted. Theoretical aspects are covered by a literature review of ground-pointing radar, vehicular radar, and velocity measuring systems. This review establishes and collates the body of knowledge in areas previously considered unrelated. Based upon this work, a new design is proposed which is suitable for incorporation into the existing company product range. Following production engineering of the design, five units were constructed, tested and evaluated on-site. After extended field trials, this design has shown itself to possess greater accuracy, reliability and versatility than the existing sensor, at a lower unit cost.
Resumo:
The research objectives were:- 1.To review the literature to establish the factors which have traditionally been regarded as most crucial to the design of effectlve exhaust ventilation systems. 2. To design, construct, install and calibrate a wind tunnel. 3. To develop procedures for air velocity measurement followed by a comprehensive programme of aerodvnamic data collection and data analysis for a variety of conditions. The major research findings were:- a) The literature in the subject is inadequate. There is a particular need for a much greater understanding of the aerodynamics of the suction flow field. b) The discrepancies between the experimentally observed centre-line velocities and those predicted by conventional formulae are unacceptably large. c) There was little agreement between theoretically calculated and observed velocities in the suction zone of captor hoods. d) Improved empirical formulae for the prediction of centre-line velocity applicable to the classical geometrically shaped suction openings and the flanged condition could be (and were) derived. Further analysis of data revealed that: - i) Point velocity is directly proportional to the suction. flow rate and the ratio of the point velocity to the average face velocity is constant. ii) Both shape, and size of the suction opening are significant factors as the coordinates of their points govern the extent of the effect of the suction flow field. iii) The hypothetical ellipsoidal potential function and hyperbolic streamlines were found experimentally to be correct. iv) The effect of guide plates depends on the size, shape and the angle of fitting. The effect was to very approximately double the suction velocity but the exact effect is difficult to predict. v) The axially symmetric openings produce practically symmetric flow fields. Similarity of connection pieces between the suction opening and the main duct in each case is essential in order to induce a similar suction flow field. Additionally a pilot study was made in which an artificial extraneous air flow was created, measured and its interaction with the suction flow field measured and represented graphically.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT