9 resultados para Turning point

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

‘Not belonging’ is becoming a prevalent theme within accounts of the first-year student experience at university. In this study the notion of not belonging is extended by assuming a more active role for the idea of liminality in a student’s transition into the university environments of academic and student life. In doing so, the article suggests that the transition between one place (home) and another (university) can result in an ‘in-between-ness’ – a betwixt space. Through an interpretative methodology, the study explores how students begin to move from this betwixt space into feeling like fully-fledged members of university life. It is concluded that there is a wide range of turning points associated with the students’ betwixt transition, which shapes, alters or indeed accentuates the ways in which they make meaningful connections with university life. Moreover, transitional turning point experiences reveal a cast of characters and symbolic objects; capture contrasting motivations and evolving relationships; display multiple trajectories of interpersonal tensions and conflicts; highlight discontinuities as well as continuities; and together, simultaneously liberate and constrain the students’ transition into university life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The subject-matter of this thesis is the interaction between the Parti Communiste Français and the National Liberation struggle in Algeria , and the debate that ensued within the Party itself.For a detailed study of the Party ' s line on the war, PCF publications were contrasted with the texts produced by the opposition.Three main axes were identified crystallising discussion within the Party during the Algerian war: The relationship between France and Algeria and the Party ' s attitude to the French nation; The nature of the Algerian nation and its genesis; France's military engagement in Algeria.The dichotomy between the Party's national and internationalist responsibilities is shown to have resolved itself by the fundamental integration of the PCF into the political structure and value system of the French Republic. This study demonstrates the birth of a substantial internal opposition to the PCF during the Algerian war.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The turning point of the refractive index (RI) sensitivity based on the multimode microfiber (MMMF) in-line Mach–Zehnder interferometer (MZI) is observed. By tracking the resonant wavelength shift of the MZI generated between the HE11 and HE12 modes in the MMMF, the surrounding RI (SRI) could be detected. Theoretical analysis demonstrates that the RI sensitivity will reach ±∞ on either side of the turning point due to the group effective RI difference (퐺) approaching zero. Significantly, the positive sensitivity exists in a very wide fiber diameter range, while the negative sensitivity can be achieved in a narrow diameter range of only 0.3 μm. Meanwhile, the experimental sensitivities and variation trend at different diameters exhibit high consistency with the theoretical results. High RI sensitivity of 10777.8 nm/RIU (RI unit) at the fiber diameter of 4.6 μm and the RI around 1.3334 is realized. The discovery of the sensitivity turning points has great significance on trace detection due to the possibility of ultrahigh RI sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Systematically investigated the waveguide dispersion characteristics of LPFGs. It has been revealed that the coupled cladding modes resonating in the dispersion-turning-point region are intrinsically sensitive to the external perturbation. Thus, LPFG-based application devices requiring good stability should avoid this region. On the other hand, this mode ultra-sensitive-zone can be explored to realise sensors and tuneable filters of high efficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis describes the study of various grating based optical fibre sensors for applications in refractive index sensing. The sensitivity of these sensors has been studied and in some cases enhanced using novel techniques. The major areas of development are as follows. The sensitivity of long period gratings (LPGs) to surrounding medium refractive index (SRI) for various periods was investigated. The most sensitive period of LPG was found to be around 160 µm and this was due to the core mode coupling to a single cladding mode but phase matching at two wavelength locations, creating two attenuation peaks, close to the waveguide dispersion turning point. Large angle tilted fibre gratings (TFGs) have similar behaviour to LPGs, in that they couple to the co-propagating cladding modes. The tilted structure of the index modulation within the core of the fibre gives rise to a polarisation dependency, differing the large angle TFG from a LPG. Since the large angle TFG couple to the cladding mode they are SRI sensitive, the sensitivity to SRI can be further increased through cladding etching using HF acid. The thinning of the cladding layer caused a reordering of the cladding modes and shifted to more SRI sensitive cladding modes as the investigation discovered. In a SRI range of 1.36 to 1.40 a sensitivity of 506.9 nm/URI was achieved for the etched large angle TFG, which is greater than the dual resonance LPG. UV inscribed LPGs were coated with sol-gel materials with high RIs. The high RI of the coating caused an increase in cladding mode effective index which in turn caused an increase in the LPG sensitivity to SRI. LPGs of various periods of LPG were coated with sol-gel TiO2 and the optimal thickness was found to vary for each period. By coating of the already highly SRI sensitive 160µm period LPG (which is a dual resonance) with a sol-gel TiO2, the SRI sensitivity was further increased with a peak value of 1458 nm/URI, which was an almost 3 fold increase compared to the uncoated LPG. LPGs were also inscribed using a femtosecond laser which produced a highly focused index change which was no uniform throughout the core of the optical fibre. The inscription technique gave rise to a large polarisation sensitivity and the ability to couple to multiple azimuthal cladding mode sets, not seen with uniform UV inscribed gratings. Through coupling of the core mode to multiple sets of cladding modes, attenuation peaks with opposite wavelength shifts for increasing SRI was observed. Through combining this opposite wavelength shifts, a SRI sensitivity was achieved greater than any single observed attenuations peak. The maximum SRI achieved was 1680 nm/URI for a femtosecond inscribed LPG of period 400 µm. Three different types of surface plasmon resonance (SPR) sensors with a multilayer metal top coating were investigated in D shape optical fibre. The sensors could be separated into two types, utilized a pre UV inscribed tilted Bragg grating and the other employed a post UV exposure to generate surface relief grating structure. This surface perturbation aided the out coupling of light from the core but also changed the sensing mechanism from SPR to localised surface plasmon resonance (LSPR). This greatly increased the SRI sensitivity, compared to the SPR sensors; with the gold coated top layer surface relief sensor producing the largest SRI sensitivity of 2111.5nm/URI was achieved. While, the platinum and silver coated top layer surface relief sensors also gave high SRI sensitivities but also the ability to produce resonances in air (not previously seen with the SPR sensors). These properties were employed in two applications. The silver and platinum surface relief devices were used as gas sensors and were shown to be capable of detecting the minute RI change of different gases. The calculated maximum sensitivities produced were 1882.1dB/URI and 1493.5nm/URI for silver and platinum, respectively. Using a DFB laser and power meter a cheap alternative approach was investigated which showed the ability of the sensors to distinguish between different gases and flow rates of those gases. The gold surface relief sensor was coated in a with a bio compound called an aptamer and it was able to detect various concentrations of a biological compound called Thrombin, ranging from 1mM to as low as 10fM. A solution of 2M NaCl was found to give the best stripping results for Thrombin from the aptamer and showed the reusability of the sensor. The association and disassociation constants were calculated to be 1.0638×106Ms-1 and 0.2482s-1, respectively, showing the high affinity of the Aptamer to thrombin. This supports existing working stating that aptamers could be alternative to enzymes for chemical detection and also helps to explain the low detection limit of the gold surface relief sensor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have experimentally investigated the mode dispersion property and refractive index sensitivity of dual-peak long-period fiber gratings (LPGs) that were sensitized by hydrofluoric acid (HF) etching. The nature of the coupled cladding modes close to the dispersion turning point makes the dual-peak LPGs ultrasensitive to cladding property, permitting a fine tailoring of the mode dispersion and index sensitivity by the light cladding etching method using HF acid of only 1% concentration. As an implementation of an optical biosensor, the etched device was used to detect the concentration of hemoglobin protein in a sugar solution, showing a sensitivity as high as 20 nm/1%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have experimentally investigated the mode dispersion property and refractive index sensitivity of dual-peak long-period fiber gratings (LPGs) that were sensitized by hydrofluoric acid (HF) etching. The nature of the coupled cladding modes close to the dispersion turning point makes the dual-peak LPGs ultrasensitive to cladding property, permitting a fine tailoring of the mode dispersion and index sensitivity by the light cladding etching method using HF acid of only 1% concentration. As an implementation of an optical biosensor, the etched device was used to detect the concentration of hemoglobin protein in a sugar solution, showing a sensitivity as high as 20 nm/1%. © 2007 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Developing a means of predicting tool life has been and continues to be a focus of much research effort. A common experience in attempting to replicate such efforts is an inability to achieve the levels of agreement between theory and practice of the original researcher or to extrapolate the work to different materials or cutting conditions to those originally used. This thesis sets out to examine why most equations or models when replicated do not give good agreements. One reason which was found is that researchers in wear prediction, their predictions are limited because they generally fail to properly identify the nature of wear mechanisms operative in their study. Also they fail to identify or recognise factors having a significant influence on wear such as bar diameter. Also in this research the similarities and differences between the two processes of single point turning and drilling are examined through a series of tests. A literature survey was undertaken in wear and wear prediction. As a result it was found that there was a paucity in information and research in the work of drilling as compared to the turning operation. This was extended to the lack of standards that exist for the drilling operation. One reason for this scarcity in information on drilling is due to the complexity of the drilling and the tool geometry of the drill. In the comparative drilling and turning tests performed in this work, the same tool material; HSS, and similar work material was used in order to eliminate the differences which may occur due to this factor. Results of the tests were evaluated and compared for the two operations and SEM photographs were taken for the chips produced. Specific test results were obtained for the cutting temperatures and forces of the tool. It was found that cutting temperature is influenced by various factors like tool geometry and cutting speed, and the temperature itself influenced the tool wear and wear mechanisms that act on the tool. It was found and proven that bar diameter influences the temperature, a factor not considered previously.