5 resultados para Trifocal

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting - Midland Eye Institute, Solihull, United Kingdom. Design - Cohort study. Methods - Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results - The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions - The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of submicron-height sine-like relief of a trifocal diffractive zone plate using a nanoimprinting technique is studied. The zone plate is intended for use in combined trifocal diffractive-refractive lenses and provides the possibility to form trifocal intraocular lenses with predetermined light intensity distribution between foci. The optical properties of the designed zone plate having the optical powers 3 D, 0, -3D in the three main diffraction orders are theoretically and experimentally investigated. The results of the theoretical investigations are in good agreement with experimental measurements. The effects of the pupil size (lens diameter) as well as the wavelength-dependent behavior of the zone plate are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premium intraocular lenses (IOLs) aim to surgically correct astigmatism and presbyopia following cataract extraction, optimising vision and eliminating the need for cataract surgery in later years. It is usual to fully correct astigmatism and to provide visual correction for distance and near when prescribing spectacles and contact lenses, however for correction with the lens implanted during cataract surgery, patients are required to purchase the premium IOLs and pay surgery fees outside the National Health Service in the UK. The benefit of using toric IOLs was thus demonstrated, both in standard visual tests and real-world situations. Orientation of toric IOLs during implantation is critical and the benefit of using conjunctival blood vessels for alignment was shown. The issue of centration of IOLs relative to the pupil was also investigated, showing changes with the amount of dilation and repeat dilation evaluation, which must be considered during surgery to optimize the visual performance of premium IOLs. Presbyopia is a global issue, of growing importance as life expectancy increases, with no real long-term cure. Despite enhanced lifestyles, changes in diet and improved medical care, presbyopia still presents in modern life as a significant visual impairment. The onset of presbyopia was found to vary with risk factors including alcohol consumption, smoking, UV exposure and even weight as well as age. A new technique to make measurement of accommodation more objective and robust was explored, although needs for further design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for refinement for optimum visual outcome in addition to outlining how premium IOLs may provide long-term and successful correction of astigmatism and presbyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Setting: Midland Eye, Solihull, United Kingdom. Design: Evaluation of a technique. Methods: Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). Results: A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Conclusion: Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2013 ASCRS and ESCRS.