8 resultados para Testing Procedure
em Aston University Research Archive
Resumo:
A description of the background to testing friction materials for automotive brakes explains the need for a rapid, inexpensive means of assessing their behaviour in a way which is both accurate and meaningful. Various methods of controlling inertia dynamometers to simulate road vehicles are rejected in favour of programming by means of a commercially available XY plotter. Investigation of brake service conditions is used to set up test schedules, and a dynamometer programming unit built to enable service conditions on vehicles to be simulated on a full scale dynamometer. A technique is developed by which accelerated testing can be achieved without operating under overload conditions, saving time and cost without sacrificing validity. The development of programming by XY plotter is described, with a method of operating one XY plotter to programme the machine, monitor its own behaviour, and plot its own results in logical sequence. Commissioning trials are described and the generation of reproducible results in frictional behaviour and material durability is discussed. Teclmiques are developed to cross check the operation of the machine in retrospect, and retrospectively correct results in the event of malfunctions. Sensitivity errors in the measuring circuits are displayed between calibrations, whilst leaving the recorded results almost unaffected by error. Typical results of brake lining tests are used to demonstrate the range of performance parameters which can be studied by use of the machine. Successful test investigations completed on the machine are reported, including comments on behaviour of cast iron drums and discs. The machine shows that materials can repeat their complex friction/ temperature/speed/pressure relationships at a reproducibility of the order of +-0.003u and +~ 0.0002 in. thickness loss during wear tests. Discussion of practical and academic implications completes the report with recommendations for further work in both fields.
Resumo:
Some of the problems arising from the inherent instability of emulsions are discussed. Aspects of emulsion stability are described and particular attention is given to the influence of the chemical nature of the dispersed phase on adsorbed film structure and stability, Emulsion stability has been measured by a photomicrographic technique. Electrophoresis, interfacial tension and droplet rest-time data were also obtained. Emulsions were prepared using a range of oils, including aliphatic and aromatic hydrocarbons, dispersed In a solution of sodium dodecyl sulphate. In some cases a small amount of alkane or alkanol was incorporated into the oil phase. In general the findings agree with the classical view that the stability of oil-in-water emulsions is favoured by a closely packed interfacial film and appreciable electric charge on the droplets. The inclusion of non-ionic alcohol leads to enhanced stability, presumably owing to the formation of a "mixed" interfacial film which is more closely packed and probably more coherent than that of the anionic surfactant alone. In some instances differences in stability cannot he accounted for simply by differences in interfacial adsorption or droplet charge. Alternative explanations are discussed and it is postulated that the coarsening of emulsions may occur not only hy coalescence but also through the migration of oil from small droplets to larger ones by molecular diffusion. The viability of using the coalescence rates of droplets at a plane interface as a guide to emulsion stability has been researched. The construction of a suitable apparatus and the development of a standard testing procedure are described. Coalescence-time distributions may be correlated by equations similar to those presented by other workers, or by an analysis based upon the log-normal function. Stability parameters for a range of oils are discussed in terms of differences in film drainage and the natl1re of the interfacial film. Despite some broad correlations there is generally poor agreement between droplet and emulsion stabilities. It is concluded that hydrodynamic factors largely determine droplet stability in the systems studied. Consequently droplet rest-time measurements do not provide a sensible indication of emulsion stability,
Resumo:
Current practice in National Health Service (NHS) hospitals employs 70% Industrial Methylated Spirit spray for surface disinfection of components required in Grade A pharmaceutical environments. This study seeks to investigate other agents and procedures that may provide more effective sanitisation. Several methods are available to test the efficacy of disinfectants against vegetative organisms. However, no methods currently available test the efficacy of disinfectants against spores on the hard surfaces encountered in the pharmacy aseptic processing environment. Therefore, a method has been developed to test the efficacy of disinfectants against spores, modified from British Standard 13697 and Association of Analytical Chemists standards. The testing procedure was used to evaluate alternative biocides and disinfection methods for transferring components into hospital pharmacy cleanrooms, and to determine which combinations of biocide and application method have the greatest efficacy against spores of Bacillus subtilis subspecies subtilis 168, Bacillus subtilis American Type Culture Collection (ATCC) 6633, and Bacillus pumilis ATCC 27142. Stainless steel carrier test plates were used to represent the hard surfaces in hospital pharmacy cleanrooms. Plates were inoculated with 10(7)-10(8) colony-forming units per milliliter (CFU/mL) and treated with the various biocide formulations, using different disinfection methods. Sporicidal activity was calculated as log reduction in CFU. Of the biocides tested, 6% hydrogen peroxide and a quaternary ammonium compound/chlorine dioxide combination were most effective compared to a Quat/biguanide, amphoteric surfactant, 70% v/v ethanol in deionised water and isopropyl alcohol in water for injection. Of the different application methods tested, spraying followed by wiping was the most effective, followed closely by wiping alone. Spraying alone was least effective.
Resumo:
This paper proposes a semiparametric smooth-coefficient stochastic production frontier model where all the coefficients are expressed as some unknown functions of environmental factors. The inefficiency term is multiplicatively decomposed into a scaling function of the environmental factors and a standard truncated normal random variable. A testing procedure is suggested for the relevance of the environmental factors. Monte Carlo study shows plausible ¯nite sample behavior of our proposed estimation and inference procedure. An empirical example is given, where both the semiparametric and standard parametric models are estimated and results are compared.
Resumo:
To what extent does competitive entry create a structural change in key marketing metrics? New players may just be a temporal nuisance to incumbents, but could also fundamentally change the latter's performance evolution, or induce them to permanently alter their spending levels and/or pricing decisions. Similarly, the addition of a new marketing channel could permanently shift shopping preferences, or could just create a short-lived migration from existing channels. The steady-state impact of a given entry or channel addition on various marketing metrics is intrinsically an empirical issue for which we need an appropriate testing procedure. In this study, we introduce a testing sequence that allows for the endogenous determination of potential change (break) locations, thereby accounting for lead and/or lagged effects of the introduction of interest. By not restricting the number of potential breaks to one (as is commonly done in the marketing literature), we quantify the impact of the new entrant(s) while controlling for other events that may have taken place in the market. We illustrate the methodology in the context of the Dutch television advertising market, which was characterized by the entry of several late movers. We find that the steady-state growth of private incumbents' revenues was slowed by the quasi-simultaneous entry of three new players. Contrary to industry observers' expectations, such a slowdown was not experienced in the related markets of print and radio advertising.
Resumo:
A sizeable amount of the testing in eye care, requires either the identification of targets such as letters to assess functional vision, or the subjective evaluation of imagery by an examiner. Computers can render a variety of different targets on their monitors and can be used to store and analyse ophthalmic images. However, existing computing hardware tends to be large, screen resolutions are often too low, and objective assessments of ophthalmic images unreliable. Recent advances in mobile computing hardware and computer-vision systems can be used to enhance clinical testing in optometry. High resolution touch screens embedded in mobile devices, can render targets at a wide variety of distances and can be used to record and respond to patient responses, automating testing methods. This has opened up new opportunities in computerised near vision testing. Equally, new image processing techniques can be used to increase the validity and reliability of objective computer vision systems. Three novel apps for assessing reading speed, contrast sensitivity and amplitude of accommodation were created by the author to demonstrate the potential of mobile computing to enhance clinical measurement. The reading speed app could present sentences effectively, control illumination and automate the testing procedure for reading speed assessment. Meanwhile the contrast sensitivity app made use of a bit stealing technique and swept frequency target, to rapidly assess a patient’s full contrast sensitivity function at both near and far distances. Finally, customised electronic hardware was created and interfaced to an app on a smartphone device to allow free space amplitude of accommodation measurement. A new geometrical model of the tear film and a ray tracing simulation of a Placido disc topographer were produced to provide insights on the effect of tear film breakdown on ophthalmic images. Furthermore, a new computer vision system, that used a novel eye-lash segmentation technique, was created to demonstrate the potential of computer vision systems for the clinical assessment of tear stability. Studies undertaken by the author to assess the validity and repeatability of the novel apps, found that their repeatability was comparable to, or better, than existing clinical methods for reading speed and contrast sensitivity assessment. Furthermore, the apps offered reduced examination times in comparison to their paper based equivalents. The reading speed and amplitude of accommodation apps correlated highly with existing methods of assessment supporting their validity. Their still remains questions over the validity of using a swept frequency sine-wave target to assess patient’s contrast sensitivity functions as no clinical test provides the range of spatial frequencies and contrasts, nor equivalent assessment at distance and near. A validation study of the new computer vision system found that the authors tear metric correlated better with existing subjective measures of tear film stability than those of a competing computer-vision system. However, repeatability was poor in comparison to the subjective measures due to eye lash interference. The new mobile apps, computer vision system, and studies outlined in this thesis provide further insight into the potential of applying mobile and image processing technology to enhance clinical testing by eye care professionals.
Resumo:
Prices and yields of UK government zero-coupon bonds are used to test alternative yield curve estimation models. Zero-coupon bonds permit a more pure comparison, as the models are providing only the interpolation service and also not making estimation feasible. It is found that better yield curves estimates are obtained by fitting to the yield curve directly rather than fitting first to the discount function. A simple procedure to set the smoothness of the fitted curves is developed, and a positive relationship between oversmoothness and the fitting error is identified. A cubic spline function fitted directly to the yield curve provides the best overall balance of fitting error and smoothness, both along the yield curve and within local maturity regions.
Resumo:
OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.