4 resultados para Telephone cables.

em Aston University Research Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the major problems associated with communication via a loudspeaking telephone (LST) is that, using analogue processing, duplex transmission is limited to low-loss lines and produces a low acoustic output. An architectural for an instrument has been developed and tested, which uses digital signal processing to provide duplex transmission between a LST and a telopnone handset over most of the B.T. network. Digital adaptive-filters are used in the duplex LST to cancel coupling between the loudspeaker and microphone, and across the transmit to receive paths of the 2-to-4-wire converter. Normal movement of a person in the acoustic path causes a loss of stability by increasing the level of coupling from the loudspeaker to the microphone, since there is a lag associated the adaptive filters learning about a non-stationary path, Control of the loop stability and the level of sidetone heard by the hadset user is by a microprocessoe, which continually monitors the system and regulates the gain. The result is a system which offers the best compromise available based on a set of measured parameters.A theory has been developed which gives the loop stability requirements based on the error between the parameters of the filter and those of the unknown path. The programme to develope a low-cost adaptive filter in LST produced a low-cost adaptive filter in LST produced a unique architecture which has a number of features not available in any similar system. These include automatic compensation for the rate of adaptation over a 36 dB range of output level, , 4 rates of adaptation (with a maximum of 465 dB/s), plus the ability to cascade up to 4 filters without loss o performance. A complex story has been developed to determine the adptation which can be achieved using finite-precision arithmatic. This enabled the development of an architecture which distributed the normalisation required to achieve optimum rate of adaptation over the useful input range. Comparison of theory and measurement for the adaptive filter show very close agreement. A single experimental LST was built and tested on connections to hanset telephones over the BT network. The LST demonstrated that duplex transmission was feasible using signal processing and produced a more comfortable means of communication beween people than methods emplying deep voice-switching to regulate the local-loop gain. Although, with the current level of processing power, it is not a panacea and attention must be directed toward the physical acoustic isolation between loudspeaker and microphone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine what issues are experienced during the first few weeks of therapy by patients, and their parents/carers, when a child/young person has been prescribed a new medicine. Method: One hundred patients aged ≤18 years of age prescribed a new medicine for ≥6 weeks were recruited from a single UK National Health Service specialist paediatric hospital outpatient pharmacy. Six weeks after the first dispensing of their new medicine the patient or their parent/carer received telephone follow-up by a researcher and verbally completed a questionnaire containing both open and closed questions. Patient or parent/carer experiences were identified and analysed using thematic analysis and descriptive statistics. Results: Eighty-six participants were available for telephone follow-up. Six (7%) had not started their medicine. Paediatric patients and their parents/carers experienced a range of issues during the first few weeks after starting a new medicine. These included additional concerns/questions (24/80, 30%), administration issues (21/80, 26.3%), adverse effects (29/80, 36.3%) and obtaining repeat supplies (12/80, 15%). The Morisky Medication Adherence Scale indicated that 34/78 (43.6%) participants had a high adherence rating, 35/78 (44.9%) medium and 9/78 (11.5%) a low rating. Conclusions: Paediatric patients and their parents/carers experience a range of issues during the first few weeks after starting a new medicine. Further research is required to determine the type of interventions that may further support medicines use in this group of patients.