8 resultados para Surgical site infection

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical site infections (SSI) are a prevalent health care-associated infection (HAl). Prior to the mid-19th century, surgical sites commonly developed postoperative wound complications. It was in the 1860's, after Joseph Lister introduced carbolic acid and the principles of antisepsis that postoperative wound infection significantly decreased. Today, patient preoperative skin preparation with an antiseptic agent prior to surgery is a standard of practice. Povidone-iodine and chlorhexidine gluconate are currently the most commonly used antimicrobial agents used to prep the patient's skin. In this current study, the epidemiology, diagnosis, surveillance and prevention of SSI with chlorhexidine were investigated. The antimicrobial activity of chlorhexidine was assessed. In in-vitro and in-vivo studies the antimicrobial efficacy of 2% (w/v) chlorhexidine gluconate (CHG) in 70% isopropyl alcohol (IPA) and 10% povidoneiodine (PVP-I) in the presence of 0.9% normal saline or blood were examined. The 2% CHG in 70% IPA solutions antimicrobial activity was not diminished in the presence of 0.9% normal saline or blood. In comparison, the traditional patient preoperative skin preparation, 10% PVP-I antimicrobial activity was not diminished in the presence of 0.9% normal saline, but was diminished in the presence of blood. In an in-vivo human volunteer study the potential for reduction of the antimicrobial efficacy of aqueous patient preoperative skin preparations compromised by mechanical removal of wet product from the application site (blot) was assessed. In this evaluation, 2% CHG and 10% povidone-iodine (PVP-I) were blotted from the patient's skin after application to the test site. The blotting, or mechanical removal, of the wet antiseptic from the application site did not produce a significant difference in product efficacy. In a clinical trial to compare 2% CHG in 70% IPA and PVP-! scrub and paint patient preoperative skin preparation for the prevention of SSI, there were 849 patients randomly assigned to the study groups (409 in the chlorhexidine-alcohol and 440 in the povidone-iodine group) in the intention-to-treat analysis. The overall surgical site infection was significantly lower in the 2% CHG in 70% IPA group than in the PVP-I group (9.5% versus 16.1 %, p=0.004; relative risk, 0.59 with 95% confidence interval of 0.41 to 0.85). Preoperative cleansing of the patient's skin with chlorhexidine-alcohol is superior to povidone-iodine in preventing surgical site infection after clean-contaminated surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To determine the sensitivity and specificity of a novel ELISA for the serodiagnosis of surgical site infection (SSI) due to staphylococci following median sternotomy. Methods: Twelve patients with a superficial sternal SSI and 19 with a deep sternal SSI due to Staphylococcus aureus were compared with 37 control patients who also underwent median sternotomy for cardiac surgery but exhibited no microbiological or clinical symptoms of infection. A further five patients with sternal SSI due to coagulase-negative (CoNS) staphylococci were studied. An ELISA incorporating a recently recognised exocellular short chain form of lipoteichoic acid (lipid S) recovered from CoNS, was used to determine serum levels of anti-lipid S IgG in all patient groups. Results: Serum anti-lipid S IgG titres of patients with sternal SSI due to S. aureus were significantly higher than the control patients (P<0.0001). In addition, patients with deep sternal SSI had significantly higher serum anti-lipid S IgG titres than patients with superficial sternal SSI (P=0.03). Serum anti-lipid S IgG titres of patients with sternal SSI due to CoNS were significantly higher than the control patients (P=0.001). Conclusion: The lipid S ELISA may facilitate the diagnosis of sternal SSI due to S. aureus and could also be of value with infection due to CoNS. © 2005 Published by Elsevier Ltd. on behalf of The Bristish Infection Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential source of CVC colonisation was assessed. Isolates of coagulase-negative staphylococci (CoNS) recovered from the skin and CVC components of 3 cardiothoracic surgery patients were characterised by pulsed-field gel electrophoresis (PFGE). The genetic heterogeneity of CoNS isolated from the skin was demonstrated and specific genotypes implicated in catheter colonisation. In addition, phenotypic and genotypic typing techniques were assessed for their ability to characterise strains of CoNS recovered from 33 patients who developed catheter-related bloodstream infection (CR-BSI) on a bone marrow transplant (BMT) unit and Siaphylococcus aureus recovered from 6 cardiothoracic surgery patients with surgical site infection (SSI) following median sternotomy. This epidemiological investigation revealed that common strains of CoNS and 51 aureus where not associated with infection in patients with CR-BSI or sternal SSI during the study period. Furthermore, there was no correlation between phenotypic and genotypic characterisation results. The variable expression of phenotypic traits within strains of staphylococci was evident whilst PFGE and randomly amplified polymorphic DNA (RAPD) were highly discriminatory for the molecular characterisation of S. aureus and CoNS. This was highlighted in 8 stem cell transplant (SCT) patients whereby it was demonstrated that routine identification and characterisation of CoNS by phenotypic techniques may not be adequate for the diagnosis of CR-BSI by current guidelines. The potential of the lipid S ELISA to facilitate the diagnosis of CR-BSI in 38 haematology/SCT patients and sternal SSI in 57 cardiothoracic surgery patients was also assessed. The ELISA proved to be a sensitive test for the rapid serodiagnosis of infection due to staphylococci in immunocompetent patients. The acridine orange leucocyte cytospin test (AOLC) was also evaluated for the rapid diagnosis of CR-BSI in 16 haematology/SCT patients with Hickman CVC in situ. Although the sensitivity of the test was low, it may provide a useful adjunct to conventional methods for the in situ sampling of catheters to predict and diagnose CR-BSI, preventing the unnecessary removal of CVC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ability of Escherichia coli to express the K88 fimbrial adhesin was satisfactorily indicated by the combined techniques of ELISA, haemagglutination and latex agglutination. Detection of expression by electron microscopy and the ability to metabolize raffinose were unsuitable. Quantitative expression of the K88 adhesin was determined by ELISA. Expression was found to vary according to the E.coli strain examined, media type and form. In general it was found that the total amount was greater, while the amount/cfu was less on agar than in broth cultures. Expression of the K88 adhesin during unshaken batch culture was related to the growth rate and was maximal during late logarithmic to early stationary phase. A combination of heat extraction, ammonium sulphate and isoelectric precipitation was found suitable for both large and small scale preparation of purified K88ab adhesin. Extraction of the K88 adhesin was sensitive to pH and it was postulated that this may affect the site of colonisation of by ETEC in vivo. Results of haemagglutination experiments were consistent with the hypothesis that the K88 receptor present on erythrocytes is composed of two elements, one responsible for the binding of K88ab and K88ac and a second responsible for the binding of the K88ad adhesin. Comparison of the haemagglutinating properties of cell-free and cell-bound K88 adhesin revealed some differences probably indicating a minor conformational change in the K88 adhesin on its isolation. The K88ab adhesin was found to bind to erythrocytes over a wide pH range (PH 4-9) and was inhibited by αK88ab and αK88b antisera. Inhibition of haemagglutination was noted with crude heparin, mannan and porcine gastric mucin, chondrosine and several hexosamines, glucosamine in particular. The most potent inhibitor of haemagglutination was n-dodecyl-β-D-glucopyranoside, one of a series of glucosides found to have inhibitory properties. Correlation between hydrophobicity of glucosides tested and degree of inhibition observed suggested hydrophobic forces were important in the interaction of the K88 adhesin with its receptor. The results of Scatchard and Hill plots indicated that binding of the K88ab adhesin to porcine enterocytes in the majority of cases is a two-step, three component system. The first K88 receptor (or site) had a K2. of 1.59x1014M-1 and a minimum of 4.3x104 sites/enterocyte. The second receptor (or site) had a K2 of 4.2x1012M-1 with a calculated 1.75x105 sites/enterocyte. Attempts to inhibit binding of cell-free K88 adhesin to porcine enterocytes by lectins were unsuccessful. However, several carbohydrates including trehalose, lactulose, galactose 1→4 mannopyranoside, chondrosine, galactosamine, stachyose and mannan were inhibitory. The most potent inhibitor was found to be porcine gastric mucin. Inhibition observed with n-octyl-α-D-glucopyranose was difficult to interpret in isolation because of interference with the assay, however, it agreed with the results of haemagglutination inhibition experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the case of surgical scalpels, blade retraction and disposability have been incorporated into a number of commercial designs to address sharps injury and infection transmission issues. Despite these new designs, the traditional metal reusable scalpel is still extensively used and this paper attempts to determine whether the introduction of safety features has compromised the ergonomics and so potentially the take-up of the newer designs. Examples of scalpels have been analysed to determine the ergonomic impact of these design changes. Trials and questionnaires were carried out using both clinical and non-clinical user groups, with the trials making use of assessment of incision quality, cutting force, electromyography and video monitoring. The results showed that ergonomic performance was altered by the design changes and that while these could be for the worse, the introduction of safety features could act as a catalyst to encourage re-evaluation of the ergonomic demands of a highly traditional product.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The antimicrobial efficacy of a chlorhexidine gluconate (CHG) intravascular catheter gel dressing was evaluated against methicillin-resistant Staphylococcus aureus (MRSA) and an extended-spectrum β-lactamase (ESBL)-producing Escherichia coli. Chlorhexidine deposition on the skin surface and release from the gel were determined. Methods: The antimicrobial efficacy was evaluated in in vitro studies following microbial inoculation of the dressing and application of the dressing on the inoculated surface of a silicone membrane and donor skin [with and without a catheter segment and/or 10% (v/v) serum] on diffusion cells. Antimicrobial activity was evaluated for up to 7 days. Chlorhexidine skin surface deposition and release were also determined. Results: MRSA and E. coli were not detectable within 5 min following direct inoculation onto the CHG gel dressing. On the silicone membrane, 3 log and 6 log inocula of MRSA were eradicated within 5 min and 1 h, respectively. Time to kill was prolonged in the presence of serum and a catheter segment. Following inoculation of donor skin with 6 log cfu of MRSA, none was detected after 24 h. Chlorhexidine was released from the gel after a lag time of 30 min and increasing amounts were detected on the donor skin surface over the 48 h test period. The CHG gel dressing retained its antimicrobial activity on the artificial skin for 7 days. Conclusions: The CHG intravascular catheter site gel dressing had detectable antimicrobial activity for up to 7 days, which should suppress bacterial growth on the skin at the catheter insertion site, thereby reducing the risk of infection. © The Author 2011. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved.