5 resultados para Strictly Positive Measure

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the MacDQoL test-retest reliability and sensitivity to change in vision over a period of one year in a sample of patients with age-related macular degeneration (AMD). DESIGN: A prospective, observational study. METHOD: Patients with AMD from an ophthalmologist's list (n = 135) completed the MacDQoL questionnaire by telephone interview and underwent a vision assessment on two occasions, one year apart. RESULTS: Among participants whose vision was stable over one year (n = 87), MacDQoL scores at baseline and follow-up were highly correlated (r = 0.95; P < .0001). Twelve of the 22 scale items had intraclass correlations of >.80; only two were correlated <.7. There was no difference between baseline and follow-up scores (P = .85), indicating excellent test-retest reliability. Poorer quality of life (QoL) at follow-up, measured by the MacDQoL present QoL overview item, was associated with deterioration in both the better eye and binocular distance visual acuity [VA] (r = 0.29; P = .001, r = 0.21; P = .016, respectively; n = 135). There was a positive correlation between deterioration in the Mac. DQoL average weighted impact score and deterioration in both binocular near VA and reading speed (r = 0.20; P = .019, r = 0.18; P = .041, respectively; n = 135). CONCLUSION: The MacDQoL has excellent test-retest reliability. Its sensitivity to change in vision status was demonstrated in correlational analyses. The measure indicates that the negative impact of AMD on QoL increases with increasing severity of visual impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Data Envelopment Analysis (DEA) is a nonparametric method for measuring the efficiency of a set of decision making units such as firms or public sector agencies, first introduced into the operational research and management science literature by Charnes, Cooper, and Rhodes (CCR) [Charnes, A., Cooper, W.W., Rhodes, E., 1978. Measuring the efficiency of decision making units. European Journal of Operational Research 2, 429–444]. The original DEA models were applicable only to technologies characterized by positive inputs/outputs. In subsequent literature there have been various approaches to enable DEA to deal with negative data. In this paper, we propose a semi-oriented radial measure, which permits the presence of variables which can take both negative and positive values. The model is applied to data on a notional effluent processing system to compare the results with those yielded by two alternative methods for dealing with negative data in DEA: The modified slacks-based model suggested by Sharp et al. [Sharp, J.A., Liu, W.B., Meng, W., 2006. A modified slacks-based measure model for data envelopment analysis with ‘natural’ negative outputs and inputs. Journal of Operational Research Society 57 (11) 1–6] and the range directional model developed by Portela et al. [Portela, M.C.A.S., Thanassoulis, E., Simpson, G., 2004. A directional distance approach to deal with negative data in DEA: An application to bank branches. Journal of Operational Research Society 55 (10) 1111–1121]. A further example explores the advantages of using the new model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurement of lipid peroxidation is a commonly used method of detecting oxidative damage to biological tissues, but the most frequently used methods, including MS, measure breakdown products and are therefore indirect. We have coupled reversed-phase HPLC with positive-ionization electrospray MS (LC-MS) to provide a method for separating and detecting intact oxidized phospholipids in oxidatively stressed mammalian cells without extensive sample preparation. The elution profile of phospholipid hydroperoxides and chlorohydrins was first characterized using individual phospholipids or a defined phospholipid mixture as a model system. The facility of detection of the oxidized species in complex mixtures was greatly improved compared with direct-injection MS analysis, as they eluted earlier than the native lipids, owing to the decrease in hydrophobicity. In U937 and HL60 cells treated in vitro with t-butylhydroperoxide plus Fe2+, lipid oxidation could not be observed by direct injection, but LC-MS allowed the detection of monohydroperoxides of palmitoyl-linoleoyl and stearoyl-linoleoyl phosphatidylcholines. The levels of hydroperoxides observed in U937 cells were found to depend on the duration and severity of the oxidative stress. In cells treated with HOCl, chlorohydrins of palmitoyloleoyl phosphatidylcholine were observed by LC-MS. The method was able to detect very small amounts of oxidized lipids compared with the levels of native lipids present. The membrane-lipid profiles of these cells were found to be quite resistant to damage until high concentrations of oxidants were used. This is the first report of direct detection by LC-MS of intact oxidized phospholipids induced in cultured cells subjected to oxidative stress.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Financing is a critical entrepreneurial activity (Shane et al. 2003) and within the study of entrepreneurship, behaviour has been identified as an area requiring further exploration (Bird et al. 2012). Since 2008 supply side conditions for SMEs have been severe and increasingly entrepreneurs have to bundle or ‘orchestrate’ funding from a variety of sources in order to successfully finance the firm (Wright and Stigliani 2013: p.15). This longitudinal study uses psychometric testing to measure the behavioural competences of a panel of sixty entrepreneurs in the Creative Industries sector. Interviews were conducted over a 3 year period to identify finance finding behaviour. The research takes a pragmatic realism perspective to examine process and the different behavioural competences of entrepreneurs. The predictive qualities of this behaviour are explored in a funding context. The research confirmed a strong behavioural characteristic as validated through interviews and psychometric testing, was an orientation towards engagement and working with other organisations. In a funding context, this manifested itself in entrepreneurs using networks, seeking advice and sharing equity to fund growth. These co-operative, collaborative characteristics are different to the classic image of the entrepreneur as a risk-taker or extrovert. Leadership and achievement orientation were amongst the lowest scores. Three distinctive groups were identified and also shown by subsequent analysis to be a positive contribution to how entrepreneurial behavioural competences can be considered. Belonging to one of these three clusters is a strong predictive indicator of entrepreneurial behaviour – in this context, how entrepreneurs access finance. These Clusters were also proven to have different characteristics in relation to funding outcomes. The study seeks to make a contribution through the development of a methodology for entrepreneurs, policy makers and financial institutions to identify competencies in finding finance and overcome problems in information asymmetry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.