37 resultados para Static Electricity
em Aston University Research Archive
Resumo:
Coleridge, looking back at the end of the ‘long eighteenth century’, remarked that the whole of natural philosophy had been ‘electrified’ by advances in the understanding of electrical phenomena. In this paper I trace the way in which these advances affected contemporary ‘neurophysiology.’ At the beginning of the long eighteenth century, neurophysiology (in spite of Swammerdam’s and Glisson’s demonstrations to the contrary) was still understood largely in terms of hollow nerves and animal spirits. At the end of that period the researches of microscopists and electricians had convinced most medical men that the old understanding had to be replaced. Walsh, Patterson, John Hunter and others had described the electric organs of electric fish. Gray and Nollet had demonstrated that electricity was not merely static, but flowed. Franklin had alerted the world to atmospheric electricity. Galvani’s frog experiments were widely known. Volta had invented his ‘pile.’ But did ‘animal electricity’ exist and was it identical to the electricity physicists studied in the inanimate world? Was the brain a gland, as Malpighi’s researches seemed to confirm., and did it secrete electricity into the nervous system? The Monros (primus and secundus), William Cullen, Luigi Galvani, Alessandro Volta, Erasmus Darwin, Luigi Rolando and François Baillarger all had their own ideas. This paper reviews these ‘long-eighteenth century’ controversies with special reference to the Edinburgh medical school and the interaction between neurophysiology and physics.
Resumo:
This paper is located within the corporate social reporting and stakeholder management literature. It is concerned with the use of the Internet as a way of communicating with stakeholders and the extent to which this communication is or is not two-way. The evidence from the electricity industry in the UK is that the Internet is used but this use is selective and there is little true dialogue. It appears that the Internet provides an opportunity for greater corporate accountability in the future but whether this potential will be fulfilled is as yet unclear. Further research of a longitudinal nature is required to see how the Internet and more specifically corporate social or stakeholder reporting develops over time.
Resumo:
Cascaded multilevel inverters-based Static Var Generators (SVGs) are FACTS equipment introduced for active and reactive power flow control. They eliminate the need for zigzag transformers and give a fast response. However, with regard to their application for flicker reduction in using Electric Arc Furnace (EAF), the existing multilevel inverter-based SVGs suffer from the following disadvantages. (1) To control the reactive power, an off-line calculation of Modulation Index (MI) is required to adjust the SVG output voltage. This slows down the transient response to the changes of reactive power; and (2) Random active power exchange may cause unbalance to the voltage of the d.c. link (HBI) capacitor when the reactive power control is done by adjusting the power angle d alone. To resolve these problems, a mathematical model of 11-level cascaded SVG, was developed. A new control strategy involving both MI (modulation index) and power angle (d) is proposed. A selected harmonics elimination method (SHEM) is taken for switching pattern calculations. To shorten the response time and simplify the controls system, feed forward neural networks are used for on-line computation of the switching patterns instead of using look-up tables. The proposed controller updates the MI and switching patterns once each line-cycle according to the sampled reactive power Qs. Meanwhile, the remainder reactive power (compensated by the MI) and the reactive power variations during the line-cycle will be continuously compensated by adjusting the power angles, d. The scheme senses both variables MI and d, and takes action through the inverter switching angle, qi. As a result, the proposed SVG is expected to give a faster and more accurate response than present designs allow. In support of the proposal there is a mathematical model for reactive powered distribution and a sensitivity matrix for voltage regulation assessment, MATLAB simulation results are provided to validate the proposed schemes. The performance with non-linear time varying loads is analysed and refers to a general review of flicker, of methods for measuring flickers due to arc furnace and means for mitigation.
Resumo:
This thesis presents a comparison of integrated biomass to electricity systems on the basis of their efficiency, capital cost and electricity production cost. Four systems are evaluated: combustion to raise steam for a steam cycle; atmospheric gasification to produce fuel gas for a dual fuel diesel engine; pressurised gasification to produce fuel gas for a gas turbine combined cycle; and fast pyrolysis to produce pyrolysis liquid for a dual fuel diesel engine. The feedstock in all cases is wood in chipped form. This is the first time that all three thermochemical conversion technologies have been compared in a single, consistent evaluation.The systems have been modelled from the transportation of the wood chips through pretreatment, thermochemical conversion and electricity generation. Equipment requirements during pretreatment are comprehensively modelled and include reception, storage, drying and communication. The de-coupling of the fast pyrolysis system is examined, where the fast pyrolysis and engine stages are carried out at separate locations. Relationships are also included to allow learning effects to be studied. The modelling is achieved through the use of multiple spreadsheets where each spreadsheet models part of the system in isolation and the spreadsheets are combined to give the cost and performance of a whole system.The use of the models has shown that on current costs the combustion system remains the most cost-effective generating route, despite its low efficiency. The novel systems only produce lower cost electricity if learning effects are included, implying that some sort of subsidy will be required during the early development of the gasification and fast pyrolysis systems to make them competitive with the established combustion approach. The use of decoupling in fast pyrolysis systems is a useful way of reducing system costs if electricity is required at several sites because• a single pyrolysis site can be used to supply all the generators, offering economies of scale at the conversion step. Overall, costs are much higher than conventional electricity generating costs for fossil fuels, due mainly to the small scales used. Biomass to electricity opportunities remain restricted to niche markets where electricity prices are high or feed costs are very low. It is highly recommended that further work examines possibilities for combined beat and power which is suitable for small scale systems and could increase revenues that could reduce electricity prices.
Resumo:
There is considerable concern over the increased effect of fossil fuel usage on the environment and this concern has resulted in an effort to find alternative, environmentally friendly energy sources. Biomass is an available alternative resource which may be converted by flash pyrolysis to produce a crude liquid product that can be used directly to substitute for conventional fossil fuels or upgraded to a higher quality fuel. Both the crude and upgraded products may be utilised for power generation. A computer program, BLUNT, has been developed to model the flash pyrolysis of biomass with subsequent upgrading, refining or power production. The program assesses and compares the economic and technical opportunities for biomass thermochemical conversion on the same basis. BLUNT works by building up a selected processing route from a number of process steps through which the material passes sequentially. Each process step has a step model that calculates the mass and energy balances, the utilities usage and the capital cost for that step of the process. The results of the step models are combined to determine the performance of the whole conversion route. Sample results from the modelling are presented in this thesis. Due to the large number of possible combinations of feeds, conversion processes, products and sensitivity analyses a complete set of results is impractical to present in a single publication. Variation of the production costs for the available products have been illustrated based on the cost of a wood feedstock. The effect of selected macroeconomic factors on the production costs of bio-diesel and gasoline are also given.
Resumo:
This paper presents some forecasting techniques for energy demand and price prediction, one day ahead. These techniques combine wavelet transform (WT) with fixed and adaptive machine learning/time series models (multi-layer perceptron (MLP), radial basis functions, linear regression, or GARCH). To create an adaptive model, we use an extended Kalman filter or particle filter to update the parameters continuously on the test set. The adaptive GARCH model is a new contribution, broadening the applicability of GARCH methods. We empirically compared two approaches of combining the WT with prediction models: multicomponent forecasts and direct forecasts. These techniques are applied to large sets of real data (both stationary and non-stationary) from the UK energy markets, so as to provide comparative results that are statistically stronger than those previously reported. The results showed that the forecasting accuracy is significantly improved by using the WT and adaptive models. The best models on the electricity demand/gas price forecast are the adaptive MLP/GARCH with the multicomponent forecast; their MSEs are 0.02314 and 0.15384 respectively.
Resumo:
This thesis proposes to explore the potential for stakeholder based accounting as a means to explain the social performance of organisations. It argues that organisations have a contract with society and as a consequence they must be accountable to that society for their actions. Further, it is suggested that as part of this accountability there is a broader need in the public interest for social accounting. Due to the pluralistic nature of modern societies it is argued that a stakeholder framework is one way in which this accountability can be achieved. In order to consider the nature of such social accounting a case study of the electricity industry in England and Wales is undertaken. This industry is very important to modern society, has significant environment implications and has a recent history of remarkable change. These factors make it an interesting and unique case within which to consider accountability. From the performance measurement and accounting literature and a series of interviews with both stakeholders and privatised companies a model of stakeholder performance is developed. This is then used to analyse the electricity industry in England and Wales since privatisation. The objective is to demonstrate how certain stakeholders have fared, whether they have won or lost. Further, institutional and resource dependency theories are used to consider what factors determine the relative success or failure of the different stakeholder groups. Finally the possible implications of recent developments in Social Accounting Standards, such as the Global Reporting Initiative (GRI), AccountAbility 1000 (AA1000) and Social Accountability 8000 (SA8000), and the potential for Internet reporting are considered.
Resumo:
Antigenic peptide is presented to a T-cell receptor (TCR) through the formation of a stable complex with a major histocompatibility complex (MHC) molecule. Various predictive algorithms have been developed to estimate a peptide's capacity to form a stable complex with a given MHC class II allele, a technique integral to the strategy of vaccine design. These have previously incorporated such computational techniques as quantitative matrices and neural networks. A novel predictive technique is described, which uses molecular modeling of predetermined crystal structures to estimate the stability of an MHC class II-peptide complex. The structures are remodeled, energy minimized, and annealed before the energetic interaction is calculated.
Resumo:
A critical review of previous research revealed that visual attention tests, such as the Useful Field of View (UFOV) test, provided the best means of detecting age-related changes to the visual system that could potentially increase crash risk. However, the question was raised as to whether the UFOV, which was regarded as a static visual attention test, could be improved by inclusion of kinetic targets that more closely represent the driving task. A computer program was written to provide more information about the derivation of UFOV test scores. Although this investigation succeeded in providing new information, some of the commercially protected UFOV test procedures still remain unknown. Two kinetic visual attention tests (DRTS1 and 2), developed at Aston University to investigate inclusion of kinetic targets in visual attention tests, were introduced. The UFOV was found to be more repeatable than either of the kinetic visual attention tests and learning effects or age did not influence these findings. Determinants of static and kinetic visual attention were explored. Increasing target eccentricity led to reduced performance on the UFOV and DRTS1 tests. The DRTS2 was not affected by eccentricity but this may have been due to the style of presentation of its targets. This might also have explained why only the DRTS2 showed laterality effects (i.e. better performance to targets presented on the left hand side of the road). Radial location, explored using the UFOV test, showed that subjects responded best to targets positioned to the horizontal meridian. Distraction had opposite effects on static and kinetic visual attention. While UFOV test performance declined with distraction, DRTS1 performance increased. Previous research had shown that this striking difference was to be expected. Whereas the detection of static targets is attenuated in the presence of distracting stimuli, distracting stimuli that move in a structured flow field enhances the detection of moving targets. Subjects reacted more slowly to kinetic compared to static targets, longitudinal motion compared to angular motion and to increased self-motion. However, the effects of longitudinal motion, angular motion, self-motion and even target eccentricity were caused by target edge speed variations arising because of optic flow field effects. The UFOV test was more able to detect age-related changes to the visual system than were either of the kinetic visual attention tests. The driving samples investigated were too limited to draw firm conclusions. Nevertheless, the results presented showed that neither the DRTS2 nor the UFOV tests were powerful tools for the identification of drivers prone to crashes or poor driving performance.
Resumo:
We present a novel device for the characterisation of static magnetic fields through monitoring wavelength shifts of femtosecond inscribed fibre Bragg grating and micromachined slot, coated with Terfenol-D. The device was sensitive to static magnetic fields and can be used as a vectoral sensor for the detection of magnetic fields as low as 0.046 mT with a resolution of ± 0.3mT in transmission and ± 0.7mT in reflection. The use of a femtosecond laser to both inscribe the FBGs and micromachine the slot in a single stage prior to coating the device significantly simplifies the fabrication.
Resumo:
There are several methods of providing series compensation for transmission lines using power electronic switches. Four methods of series compensation have been examined in this thesis, the thyristor controlled series capacitor, a voltage sourced inverter series compensator using a capacitor as the series element, a current sourced inverter series compensator and a voltage sourced inverter using an inductor as the series element. All the compensators examined will provide a continuously variable series voltage which is controlled by the switching of the electronic switches. Two of the circuits will offer both capacitive and inductive compensation, the thyristor controlled series capacitor and the current sourced inverter series compensator. The other two will produce either capacitive or inductive series compensation. The thyristor controlled series capacitor offers the widest range of series compensation. However, there is a band of unavailable compensation between 0 and 1 pu capacitive compensation. Compared to the other compensators examined the harmonic content of the compensating voltage is quite high. An algebraic analysis showed that there is more than one state the thyristor controlled series capacitor can operate in. This state has the undesirable effect of introducing large losses. The voltage sourced inverter series compensator using a capacitor as the series element will provide only capacitive compensation. It uses two capacitors which increase the cost of the compensator significantly above the other three. This circuit has the advantage of very low harmonic distortion. The current sourced inverter series compensator will provide both capacitive and inductive series compensation. The harmonic content of the compensating voltage is second only to the voltage sourced inverter series compensator using a capacitor as the series element. The voltage sourced inverter series compensator using an inductor as the series element will only provide inductive compensation, and it is the least expensive compensator examined. Unfortunately, the harmonics introduced by this circuit are considerable.
Resumo:
This thesis analyses the impact of deregulation on the theory and practice of investment decision making in the electricity sector and appraises the likely effects on its long term future inefficiency. Part I describes the market and its shortcomings in promoting an optimal generation margin and plant mix and in reducing prices through competition. A full size operational model is developed to simulate hour by hour operation of the market and analyse its features. A relationship is established between the SMP and plant mix and between the LOLP and plant margin and it is shown bow a theoretical optimum can be derived when the combined LOLP payments and the capital costs of additional generation reach a minimum. A comparison of prices against an idealised bulk supply tariff is used to show how energy prices have risen some 12% in excess of what might have occurred under the CEGB regime. This part concludes with proposals to improve the marl
Resumo:
This thesis investigates the cost of electricity generation using bio-oil produced by the fast pyrolysis of UK energy crops. The study covers cost from the farm to the generator’s terminals. The use of short rotation coppice willow and miscanthus as feedstocks was investigated. All costs and performance data have been taken from published papers, reports or web sites. Generation technologies are compared at scales where they have proved economic burning other fuels, rather than at a given size. A pyrolysis yield model was developed for a bubbling fluidised bed fast pyrolysis reactor from published data to predict bio-oil yields and pyrolysis plant energy demands. Generation using diesel engines, gas turbines in open and combined cycle (CCGT) operation and steam cycle plants was considered. The use of bio-oil storage to allow the pyrolysis and generation plants to operate independently of each other was investigated. The option of using diesel generators and open cycle gas turbines for combined heat and power was examined. The possible cost reductions that could be expected through learning if the technology is widely implemented were considered. It was found that none of the systems analysed would be viable without subsidy, but with the current Renewable Obligation Scheme CCGT plants in the 200 to 350 MWe range, super-critical coal fired boilers co-fired with bio-oil, and groups of diesel engine based CHP schemes supplied by a central pyrolysis plant would be viable. It was found that the cost would reduce with implementation and the planting of more energy crops but some subsidy would still be needed to make the plants viable.