2 resultados para Standardised testing

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A standardised defocus area metric and reading performance index metric were devised for the evaluation of the range of focus and the reading ability of subjects implanted with presbyopic correcting IOLs. The range of clear vision after implantation of an MIOL is extended by a second focal point; however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed to allow the accurate assessment of IOL rotation, which was used to determine the rotational and positional stability of a closed loop haptic IOL. A new commercially available biometry device was validated for use with subjects prior to cataract surgery. The optical low coherence reflectometry instrument proved to be a valid method for assessing ocular biometry and covered a wider range of ocular parameters in comparison with previous instruments. The advantages of MIOLs were shown to include an extended range of clear vision translating into greater reading ability. However, an increased prevalence of dysphotopsia was shown with a bespoke halometer, which was dependent on the MIOL optic design. Implantation of a single optic accommodating IOL did not improve reading ability but achieved high subjective ratings of near vision. The closed-loop haptic IOL displayed excellent rotational stability in the late period but relatively poor rotational stability in the early period post implantation. The orientation error was compounded by the high frequency of positional misalignment leading to an extensive overall misalignment of the IOL. This thesis demonstrates the functionality of new IOL lens designs and the importance of standardised testing methods, thus providing a greater understanding of the consequences of implanting these IOLs. Consequently, the findings of the thesis will influence future designs of IOLs and testing methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Cancer-related self-tests are currently available to buy in pharmacies or over the internet, including tests for faecal occult blood, PSA and haematuria. Self-tests have potential benefits (e.g. convenience) but there are also potential harms (e.g. delays in seeking treatment). The extent of cancer-related self-test use in the UK is not known. This study aimed to determine the prevalence of cancer-related self-test use. Methods: Adults (n = 5,545) in the West Midlands were sent a questionnaire that collected socio-demographic information and data regarding previous and potential future use of 18 different self-tests. Prevalence rates were directly standardised to the England population. The postcode based Index of Multiple Deprivation 2004 was used as aproxy measure of deprivation. Results: 2,925 (54%) usable questionnaires were returned. 1.2% (95% CI 0.83% to 1.66%) of responders reported having used a cancer related self test kit and a further 36% reported that they would consider using one in the future. Logistic regression analyses suggest that increasing age, deprivation category and employment status were associated with cancer-related self-test kit use. Conclusion: We conclude that one in 100 of the adult population have used a cancer-related self-test kit and over a third would consider using one in the future. Self-test kit use could alter perceptions of risk, cause psychological morbidity and impact on the demand for healthcare.