6 resultados para Spray water

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to investigate the influence of process parameters during dry coating on particle and dosage form properties upon varying the surface adsorbed moisture of microcrystalline cellulose (MCC), a model filler/binder for orally disintegrating tablets (ODTs). METHODS: The moisture content of MCC was optimised using the spray water method and analysed using thermogravimetric analysis. Microproperty/macroproperty assessment was investigated using atomic force microscopy, nano-indentation, scanning electron microscopy, tablet hardness and disintegration testing. KEY FINDINGS: The results showed that MCC demonstrated its best flowability at a moisture content of 11.2% w/w when compared to control, comprising of 3.9% w/w moisture. The use of the composite powder coating process (without air) resulted in up to 80% increase in tablet hardness, when compared to the control. The study also demonstrated that surface adsorbed moisture can be displaced upon addition of excipients during dry processing circumventing the need for particle drying before tabletting. CONCLUSIONS: It was concluded that MCC with a moisture content of 11% w/w provides a good balance between powder flowability and favourable ODT characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature pertaining to the key stages of spray drying has been reviewed in the context of the mathematical modelling of drier performance. A critical review is also presented of previous spray drying models. A new mathematical model has been developed for prediction of spray drier performance. This is applicable to slurries of rigid, porous crust-forming materials to predict trajectories and drying profiles for droplets with a distribution of sizes sprayed from a centrifugal pressure nozzle. The model has been validated by comparing model predictions to experimental data from a pilot-scale counter-current drier and from a full-scale co-current drier. For the latter, the computed product moisture content was within 2%, and the computed air exit temperature within 10oC of experimental data. Air flow patterns have been investigated in a 1.2m diameter transparent countercurrent spray tower by flow visualisation. Smoke was introduced into various zones within the tower to trace the direction, and gauge the intensity, of the air flow. By means of a set of variable-angle air inlet nozzles, a variety of air entry configurations was investigated. The existence of a core of high rotational and axial velocity channelling up the axis of the tower was confirmed. The stability of flow within the core was found to be strongly dependent upon the air entry arrangement. A probe was developed for the measurement of air temperature and humidity profiles. This was employed for studying evaporation of pure water drops in a 1.2m diameter pilot-scale counter-current drier. A rapid approach to the exit air properties was detected within a 1m distance from the air entry ports. Measured radial profiles were found to be virtually flat but, from the axial profiles, the existence of plug-flow, well-mixed-flow and some degree of air short-circuiting can be inferred. The model and conclusions should assist in the improved design and optimum operation of industrial spray driers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High velocity oxyfuel (HVOF) thermal spraying is one of the most significant developments in the thermal spray industry since the development of the original plasma spray technique. The first investigation deals with the combustion and discrete particle models within the general purpose commercial CFD code FLUENT to solve the combustion of kerosene and couple the motion of fuel droplets with the gas flow dynamics in a Lagrangian fashion. The effects of liquid fuel droplets on the thermodynamics of the combusting gas flow are examined thoroughly showing that combustion process of kerosene is independent on the initial fuel droplet sizes. The second analysis copes with the full water cooling numerical model, which can assist on thermal performance optimisation or to determine the best method for heat removal without the cost of building physical prototypes. The numerical results indicate that the water flow rate and direction has noticeable influence on the cooling efficiency but no noticeable effect on the gas flow dynamics within the thermal spraying gun. The third investigation deals with the development and implementation of discrete phase particle models. The results indicate that most powder particles are not melted upon hitting the substrate to be coated. The oxidation model confirms that HVOF guns can produce metallic coating with low oxidation within the typical standing-off distance about 30cm. Physical properties such as porosity, microstructure, surface roughness and adhesion strength of coatings produced by droplet deposition in a thermal spray process are determined to a large extent by the dynamics of deformation and solidification of the particles impinging on the substrate. Therefore, is one of the objectives of this study to present a complete numerical model of droplet impact and solidification. The modelling results show that solidification of droplets is significantly affected by the thermal contact resistance/substrate surface roughness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SD Apo Lactoferrin-Tobramycin/Gentamicin Combinations are superior to monotherapy in the eradication of Pseudomonas aeruginosa Biofilm in the lungs Wilson Oguejiofor1, Lindsay J. Marshall1, Andrew J. Ingham1, Robert Price2, Jag. Shur2 1School of Life and Health Sciences, Aston University, Birmingham, UK. 2School of Pharmacy and Pharmacology, University of Bath, Bath, UK. KEYWORDS: lactoferrin, apo lactoferrin, spray drying, biofilm, cystic fibrosis Introduction Chronic lung infections from the opportunistic pathogeen Pseudomonas aeruginosa has been recognised as a major contributor to the incidences of high morbidity and mortality amongst cystic fibrosis (CF) patients (1,2). Currently, strategies for managing lung infections in CF patients involves the aggressive use of aerosolised antibiotics (3), however, increasing evidence suggests that the biofilm component of P. aeruginosa in the lower airway remains unperturbed and is associated with the development of antibiotic resistance. If this is so then, there is an urgent need to suitably adjust the current treatment strategy so that it includes compounds that prevent biofilm formation or disrupt established biofilms. It is well understood that biofilm formation is strongly dependent on iron (Fe3+) availability (4), therefore aerosolised anti-infective formulations which has the ability to chelate iron may essentially be a well suited therapy for eliminating P. aeruginosa biofilms on CF airway epithelial cells (5). In this study, we report the use of combination therapy; an aminoglycosides (tobramycin and gentamicin) and an antimicrobial peptide (lactoferrin) to significantly deplete P. aeruginosa biofilms. We demonstrate that lactoferrin-tobramycin and lactoferrin-gentamicin combinations are superior to the single antibiotic regime currently being employed to combat P. aeruginosa biofilms. MATERIALS AND METHOD Antibiotics: The antibiotics used in this study included gentamicin and tobramycin supplied by Fagron, UK. Bacterial strain and growth conditions: Pseudomonas aeruginosa strain PAO1 was provided by Prof. Peter Lambert of Aston University, Birmingham UK. The Strains were routinely grown from storage in a medium supplemented with magnesium chloride, glucose and casamino acids. Dialysis of lactoferrin: Apo lactoferrin was prepared by dialyzing a suspension of lactoferrin for 24 hrs at 4 °C against 20 mmol/L sodium dihydrogen phosphate, 20 mmol/L sodium acetate and 40 mmol/L EDTA (pH 3.5). Ferric ion (Fe3+) removal was verified by atomic absorption spectroscopy measurements. Spray drying of combinations of lactoferrin and apo lactoferrin with the different aminoglycosides: Combinations of tobramycin and gentamicin with the different preparations of lactoferrin were spray dried (SD) as a 2% (w/v) aqueous suspension. The spray drying parameters utilized for the production of suitable micron-sized particles includes: Inlet temperature, 180°C, spray flow rate, 606 L/hr; pump setting, 10%; aspirator setting, 85% (34m3/hr) to produce various outlet temperatures ranging from 99 - 106°C. Viability assay: To test the bactericidal activity of the various combinations, a viability assay was performed as previously described by Xu, Xiong et al. (6) with some modifications. Briefly, 10µL of ~ c. 6.6 x 107 CFU mL-1 P. aeruginosa strain PAO1 suspension were incubated (37°C, 60 mins) with 90 µL of a 2 µg/mL concentration of the various combinations and sampled every 10 mins. After incubation, the cells were diluted in deionised water and plated in Mueller hinton agar plates. Following 24 h incubation of the plates at 37°C, the percentage of viable cells was determined relative to incubation without added antibiotics. Biofilm assay: To test the susceptibility of the P. aeruginosa strain to various antibiotics in the biofilms mode of growth, overnight cultures of P. aeruginosa were diluted 1:100 into fresh medium supplemented with magnesium chloride, glucose and casamino acids. Aliquots of the dilution were dispensed into a 96 well dish and incubated (37°C, 24 h). Excess broth was removed and the number of colony forming units per milliliter (CFU/mL) of the planktonic bacteria was quantified. The biofilms were then washed and stained with 0.1% (w/v) crystal violet for 15 mins at room temperature. Following vigorous washing with water, the stained biofilms were solubilized in 30% acetic acid and the absorbance at 550nm of a 125 µL aliquot was determined in a microplate reader (Multiskan spectrum, Thermo Scientific) using 30% acetic acid in water as the blank. Aliquots of the broth prior to staining were used as an indicator of the level of planktonic growth. RESULTS AND DISCUSSION Following spray drying, the mean yield, volume weighted mean diameter and moisture content of lactoferrin powder were measured and were as follows (Table 1 and table 2); Table 1: Spray drying parameters FormulationInlet temp (°C)Outlet temp (°C)Airflow rate (L/hr)Mean yield (%)Moisture content (%) SD Lactoferrin18099 - 10060645.2 ±2.75.9 ±0.4 SD Apo Lactoferrin180100 - 10260657.8 ±1.85.7 ±0.2 Tobramycin180102 - 10460682.1 ±2.23.2 ±0.4 Lactoferrin + Tobramycin180104 - 10660687.5 ±1.43.7 ±0.2 Apo Lactoferrin + Tobramycin180103 - 10460676.3 ±2.43.3 ±0.5 Gentamicin18099 - 10260685.4 ±1.34.0 ±0.2 Lactoferrin + Gentamicin180102 - 10460687.3 ±2.13.9 ±0.3 Apo Lactoferrin + Gentamicin18099 -10360680.1±1.93.4 ±0.4 Table 2: Particle size distribution d10 d50d90 SD Lactoferrin1.384.9111.08 SD Apo Lactoferrin1.284.7911.04 SD Tobramycin1.254.9011.29 SD Lactoferrin + Tobramycin1.175.2715.23 SD Apo Lactoferrin + Tobramycin1.115.0614.31 SD Gentamicin1.406.0614.38 SD Lactoferrin + Gentamicin1.476.2314.41 SD Apo Lactoferrin + Gentamicin1.465.1511.53 The bactericidal activity of the various combinations were tested against P. aeruginosa PAO1 following a 60 minute incubation period (Figure 1 and Figure 2). While 2 µg/mL of a 1:1 combination of spray dried apo lactoferrin and Gentamicin was able to completely kill all bacterial cells within 40 mins, the same concentration was not as effective for the other antibiotic combinations. However, there was an overall reduction of bacterial cells by over 3 log units by the other combinations within 60 mins. Figure 1: Logarithmic plot of bacterial cell viability of various combinations of tobramycin and lactoferrin preparations at 2µg/mL (n = 3). Figure 2: Logarithmic plot of bacterial cell viability of various combinations of gentamicin and lactoferrin preparations at 2µg/mL (n = 3). Crystal violet staining showed that biofilm formation by P. aeruginosa PAO1 was significantly (ANOVA, p < 0.05) inhibited in the presence of the different lactoferrin preparations. Interestingly, apo lactoferrin and spray dried lactoferrin exhibited greater inhibition of both biofilm formation and biofilm persistence (Figure 2). Figure 2: Crystal violet staining of residual biofilms of P. aeruginosa following a 24hr incubation with the various combinations of antibiotics and an exposure to 48 hr formed biofilms. CONCLUSION In conclusion, combination therapy comprising of an antimicrobial peptide (lactoferrin) and an aminoglycosides (tobramycin or gentamicin) provides a feasible and alternative approach to monotherapy since the various combinations are more efficient than the respective monotherapy in the eradication of both planktonic and biofilms of P. aeruginosa. ACKNOWLEDGEMENT The authors would like to thank Mr. John Swarbrick and Friesland Campina for their generous donation of the Lactoferrin. REFERENCES 1.Hassett, D.J., Sutton, M.D., Schurr, M.J., Herr, A.B., Caldwell, C.C. and Matu, J.O. (2009), "Pseudomonas aeruginosa hypoxic or anaerobic biofilm infections within cystic fibrosis airways". Trends in Microbiology, 17, 130-138. 2.Trust, C.F. (2009), "Antibiotic treatment for cystic fibrosis". Report of the UK Cystic Fibrosis Trust Antibiotic Working Group. Consensus document. London: Cystic Fibrosis Trust. 3.Garcia-Contreras, L. and Hickey, A.J. (2002), "Pharmaceutical and biotechnological aerosols for cystic fibrosis therapy". Advanced Drug Delivery Reviews, 54, 1491-1504. 4.O'May, C.Y., Sanderson, K., Roddam, L.F., Kirov, S.M. and Reid, D.W. (2009), "Iron-binding compounds impair Pseudomonas aeruginosa biofilm formation, especially under anaerobic conditions". J Med Microbiol, 58, 765-773. 5.Reid, D.W., Carroll, V., O'May, C., Champion, A. and Kirov, S.M. (2007), "Increased airway iron as a potential factor in the persistence of Pseudomonas aeruginosa infection in cystic fibrosis". European Respiratory Journal, 30, 286-292. 6.Xu, G., Xiong, W., Hu, Q., Zuo, P., Shao, B., Lan, F., Lu, X., Xu, Y. and Xiong, S. (2010), "Lactoferrin-derived peptides and Lactoferricin chimera inhibit virulence factor production and biofilm formation in Pseudomonas aeruginosa". J Appl Microbiol, 109, 1311-1318.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of antimicrobial peptides and proteins as potential therapeutic agents in the management of multi-drug resistant infections is considered an attractive concept especially since such compounds should theoretically have low immunogenicity, high bioavailability with negligible toxicity. In this study we investigated the potential of developing a dry powder inhaler formulation of lactoferrin (a multifunctional iron binding protein). To achieve this, the protein was spray dried from a water only feedstock with suitably adjusted spray drying parameters. The particle size, degree of crystallinity, moisture content and yield of the spray dried powders along with the minimum bactericidal concentration (MBC) against Pseudomonas aeruginosa strain PAO1, were assessed. Dry powder inhaler formulations were prepared, and in vitro assessment studies using the multistage impinger were carried out to assess the aerosolisation performance of the formulations. Data obtained indicate that spray dried lactoferrin retains activity against biofilms and may be successfully employed in the treatment of chronic airway infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sustained delivery of multiple agents to the lung offers potential benefits to patients. This study explores the preparation of highly respirable dual-loaded spray-dried double emulsions. Spray-dried powders were produced from water-in-oil-in-water (w/o/w) double emulsions, containing salbutamol sulphate and/or beclometasone dipropionate in varying phases. The double emulsions contained the drug release modifier polylactide co-glycolide (PLGA 50 : 50) in the intermediate organic phase of the original micro-emulsion and low molecular weight chitosan (Mw<190 kDa: emulsion stabilizer) and leucine (aerosolization enhancer) in the tertiary aqueous phase. Following spray-drying resultant powders were physically characterized: with in vitro aerosolization performance and drug release investigated using a Multi-Stage Liquid Impinger and modified USP II dissolution apparatus, respectively. Powders generated were of a respirable size exhibiting emitted doses of over 95% and fine particle fractions of up to 60% of the total loaded dose. Sustained drug release profiles were observed during dissolution for powders containing agents in the primary aqueous and secondary organic phases of the original micro-emulsion; the burst release of agents was witnessed from the tertiary aqueous phase. The novel spray-dried emulsions from this study would be expected to deposit and display sustained release character in the lung.