10 resultados para Spectral filters

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual stress is a condition characterised by symptoms of eyestrain, headaches and distortions of visual perception when reading text. The symptoms are frequently alleviated with spectral filters and precision tinted ophthalmic lenses. Visual stress is thought to arise due to cortical hyperexcitability and is associated with a range of neurological conditions. Cortical hyperexcitability is known to occur following stroke. The case presented describes visual stress symptoms resulting from stroke, subsequently managed with spectral filters and precision tinted ophthalmic lenses. The case also highlights that the spectral properties of the tint may need to be modified if the disease course alters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present thesis investigates pattern glare susceptibility following stroke and the immediate and prolonged impact of prescribing optimal spectral filters on reading speed, accuracy and visual search performance. Principal observations: A case report has shown that visual stress can occur following stroke. The use of spectral filters and precision tinted lenses proved to be a successful intervention in this case, although the parameters required modification following a further stroke episode. Stroke subjects demonstrate elevated levels of pattern glare compared to normative data values and a control group. Initial use of an optimal spectral filter in a stroke cohort increased reading speed by ~6% and almost halved error scores, findings not replicated in a control group. With the removal of migraine subjects reading speed increased by ~8% with an optimal filter and error scores almost halved. Prolonged use of an optimal spectral filter for stroke subjects, increased reading speed by >9% and error scores more than halved. When the same subjects switched to prolonged use of a grey filter, reading speed reduced by ~4% and error scores increased marginally. When a second group of stroke subjects used a grey filter first, reading speed decreased by ~3% but increased by ~3% with prolonged use of an optimal filter, with error scores almost halving; these findings persisted with migraine subjects excluded. Initial use of an optimal spectral filter improved visual search response time but not error scores in a stroke cohort with migraine subjects excluded. Neither prolonged use of an optimal nor grey filter improved response time or reduced error scores in a stroke group; these findings persisted with the exclusion of migraine subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual search impairment can occur following stroke. The utility of optimal spectral filters on visual search in stroke patients has not been considered to date. The present study measured the effect of optimal spectral filters on visual search response time and accuracy, using a task requiring serial processing. A stroke and control cohort undertook the task three times: (i) using an optimally selected spectral filter; (ii) the subjects were randomly assigned to two groups with group 1 using an optimal filter for two weeks, whereas group 2 used a grey filter for two weeks; (iii) the groups were crossed over with group 1 using a grey filter for a further two weeks and group 2 given an optimal filter, before undertaking the task for the final time. Initial use of an optimal spectral filter improved visual search response time but not error scores in the stroke cohort. Prolonged use of neither an optimal nor a grey filter improved response time or reduced error scores. In fact, response times increased with the filter, regardless of its type, for stroke and control subjects; this outcome may be due to contrast reduction or a reflection of task design, given that significant practice effects were noted. © 2013 a Pion publication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - The aim of the study was to determine the effect of optimal spectral filters on reading performance following stroke. Methods - Seventeen stroke subjects, aged 43-85, were considered with an age-matched Control Group (n = 17). Subjects undertook the Wilkins Rate of Reading Test on three occasions: (i) using an optimally selected spectral filter; (ii) subjects were randomly assigned to two groups: Group 1 used an optimal filter, whereas Group 2 used a grey filter, for two-weeks. The grey filter had similar photopic reflectance to the optimal filters, intended as a surrogate for a placebo; (iii) the groups were crossed over with Group 1 using a grey filter and Group 2 given an optimal filter, for two weeks, before undertaking the task once more. An increase in reading speed of >5% was considered clinically relevant. Results - Initial use of a spectral filter in the stroke cohort, increased reading speed by ~8%, almost halving error scores, findings not replicated in controls. Prolonged use of an optimal spectral filter increased reading speed by >9% for stroke subjects; errors more than halved. When the same subjects switched to using a grey filter, reading speed reduced by ~4%. A second group of stroke subjects used a grey filter first; reading speed decreased by ~3% but increased by ~4% with an optimal filter, with error scores almost halving. Conclusions - The present study has shown that spectral filters can immediately improve reading speed and accuracy following stroke, whereas prolonged use does not increase these benefits significantly. © 2013 Spanish General Council of Optometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work was to measure susceptibility to pattern glare within a stroke group, employing a direct method of assessment. Twenty stroke subjects, aged 38-85 years, were recruited, along with an age-matched control group (n = 20). Assessment of pattern glare susceptibility was undertaken using the pattern glare test. An abnormal degree of pattern glare is present when individuals score >1 on the mid-high spatial frequency difference variable, a relative score that allows for normalization of the subject, or >3 when viewing the mid spatial frequency grating. Stroke subjects demonstrate elevated levels of pattern glare compared to normative data values and a control population, as determined using the pattern glare test. This was most notable when considering the output measure for the mid-high difference variable. The mean score for the mid-high difference variable was 2.15 SD 1.27 for the stroke subjects versus 0.10 SD 1.12 for the control subjects. When considering the mid-high difference variable, 75% of the stroke group recorded an abnormal level of pattern glare compared to 5% in the control group. This study demonstrates an association between stroke subjects and elevated levels of pattern glare. Cortical hyperexcitability has been shown to present following stroke, and this has been proposed as a plausible explanation for the perceptual distortions experienced by individuals susceptible to pattern glare. Further work to assess the benefits of spectral filters in reducing perceptual distortions in stroke patients is currently underway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microwave photonic responses of superstructured fiber Bragg gratings in combination with dispersive fiber are investigated theoretically and experimentally. The superstructured gratings are optimized, taking account of the spectral response of the broad-band source, Erbium-doped fiber amplifier, and optical tunable filter to achieve a filter response with sidelobe suppression of more than 60 dB. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The microwave photonic responses of superstructured fiber Bragg gratings in combination with dispersive fiber are investigated theoretically and experimentally. The superstructured gratings are optimized, taking account of the spectral response of the broad-band source, erbium-doped fiber amplifier, and optical tunable filter to achieve a filter response with sidelobe suppression of more than 60 dB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report all-fiber polarization interference filters, known as Lyot and Lyot-Ohman filters, based on alternative concatenation of UV-inscribed fiber gratings with structure tilted at 45° and polarization maintaining (PM) fiber cavities. Such filters generate comb-like transmission of linear polarization output. The free spectral range (FSR) of a single-stage (Lyot) filter is PM fiber cavity length dependent, as a 20 cm long cavity showed a 26.6 nm FSR while the 40 cm one exhibited a 14.8 nm FSR. Furthermore, we have theoretically and experimentally demonstrated all-fiber 2-stage and 3-stage Lyot-Ohman filters, giving more freedom in tailoring the transmission characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a new technique for extracting histological parameters from multi-spectral images of the ocular fundus. The new method uses a Monte Carlo simulation of the reflectance of the fundus to model how the spectral reflectance of the tissue varies with differing tissue histology. The model is parameterised by the concentrations of the five main absorbers found in the fundus: retinal haemoglobins, choroidal haemoglobins, choroidal melanin, RPE melanin and macular pigment. These parameters are shown to give rise to distinct variations in the tissue colouration. We use the results of the Monte Carlo simulations to construct an inverse model which maps tissue colouration onto the model parameters. This allows the concentration and distribution of the five main absorbers to be determined from suitable multi-spectral images. We propose the use of "image quotients" to allow this information to be extracted from uncalibrated image data. The filters used to acquire the images are selected to ensure a one-to-one mapping between model parameters and image quotients. To recover five model parameters uniquely, images must be acquired in six distinct spectral bands. Theoretical investigations suggest that retinal haemoglobins and macular pigment can be recovered with RMS errors of less than 10%. We present parametric maps showing the variation of these parameters across the posterior pole of the fundus. The results are in agreement with known tissue histology for normal healthy subjects. We also present an early result which suggests that, with further development, the technique could be used to successfully detect retinal haemorrhages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have demonstrated the feasibility of error-free DWDM 8×40 Gb/s transmission over an 800 km SMF/DCF link with 0.8 bit/s/Hz spectral efficiency without polarization multiplexing.