10 resultados para Spectral Characterization

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication and characterization of long-period gratings (LPGs) in fiber tapers is presented alongside supporting theory. The devices possess a high sensitivity to the index of aqueous solutions due to an observed spectral bifurcation effect, yielding a limiting index resolution of ±8.5×10-5 for solutions with an index in the range 1.330-1.335.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Dimroth rearrangement in ring-fused 1,2,4-triazoles has been reviewed in detail in Part I and the synthesis of all known triazolo-triazines is described in Part II. Experimental investigations concerned the establishinent of the skeletal arrangement of a variety of triazolotriazines formed by several synthetic routes. Interaction of 3-amino-5-hydrazino-12,4-triazole and benzilafforded 2-amino-6, 7-diphenyl-1, 2,4-triazolo[ 5, 1-c-]-1,2,4-triazine,whereas cyclization of 5,6-diphenyl-3-hydrazino-1,2,4-triazine withcyanogen bromide resulted in the isomeric 3-amino-6,7-diphenyl,-1,2,4-triazolo [4, 3-b]-1,2,4-triazine: both amines were deaminated with amyl nitrite in boiling tetrahydrofuran without rearrangement of the heterocyclic skeleton. 6,7-Diphenyl-1,2,4-triazolo[5,1-cJ-1,2.4-triazine, synthesized from 3-hydrazino-1,2,4-triazole and benzil, formed a covalent hydrate which could be detected spectroscopically in solution, and a covalemt methanolate and ethanolate which could be isolated. A new route to 3-amino-5-hydrazino-pyrazole is described and cyclization to 7-amino-3,4-diphenyl-pyrazolo[ 5,1-.c]-1,2,4-triazine was achieved with benzil. The diazonium nitrate of 3-amino-1,2,4-triazole coupled with ethyl cyanoacetate to yield a mixture of two geometrical isomers of ethyl 2-(2H-1,2,4-triazol-3-ylhydrazono) cyanoacetate.Recrystallization of the crude coupling mixture from aqueous ethanol gave a single hydra-zone which cyclized predominantly to ethyl 7-amino-1,2,4-triazolo[5,1-c]-1,2,4-triazine-6-carboxylate in acid conditions and 6-cyano-1,2,4-triazolo[ 5,1-c]-1,2,4~triazin-7(4H)-one under basic conditions. The nature of the cyclizing medium also controlled the cyclization of .the (pyrazol-ylhydrazono) cyanoacetate hut the corresponding (tetrazol- ylhydrazono) cyanoacetate gave only ethyl 7-aminotetrazolo[ 5,1-cJ-1,2,4- -triazine-6-carboxylate. 2-( 2H-1,2,4-Triazol-3-:ylhydrazono) malonitrile cyclized unambiguously to 7-amino-6-cyano-1,2,4-triazolo-[ 5,1-c]-1,2,4- triazine. Drastic hydrolysis of ethyl 2-(2H-1,2,4-triazol-3-yllhydrazono)-cyanoacetate, ethyl 7-amino-1, 2,4-triazolo[ 5,1-c]-1,2,4-triazine-6-carboxylate, 6-cyano-1,2,4-triazolo[ 5,1-c]-1,2,4-triazin-7{ 4H)-one and 7-amino-6- cyano-1,2,4-triazolo[5,1-c]-1,2,4-triazine gave a hydrate of 1,2,4-triazo1o[5,1-c ]-1,2,4-triazin-7(4H)-one. Mass spectral fragmentations of 7-aminoazolo-[5,1-c]-1,2,4-triazinesconfirm that the azole ring is more stable than the 1,2,4-triazine ring on electron impact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Grafted GMA on EPR samples were prepared in a Thermo-Haake internal mixer by free radical melt grafting reactions in the absence (conventional system; EPR-g-GMA(CONV)) and presence of the reactive comonomer divinyl benzene, DVB (EPR-g-GMA(DVB)). The GMA-homopolymer (poly-GMA), a major side reaction product in the conventional system, was almost completely absent in the DVB-containing system, the latter also resulted in a much higher level of GMA grafting. A comprehensive microstructure analysis of the formed poly-GMA was performed based on one-dimensional H-1 and C-13 NMR spectroscopy and the complete spectral assignments were supported by two-dimensional NMR techniques based on long range two and three bond order carbon-proton couplings from HMBC (Heteronuclear Multiple Bond Coherence) and that of one bond carbon-proton couplings from HSQC (Heteronuclear Single Quantum Coherence), as well as the use of Distortionless Enhancement by Polarization Transfer (DEPT) NMR spectroscopy. The unambiguous analysis of the stereochemical configuration of poly-GMA was further used to help understand the microstructures of the GMA-grafts obtained in the two different free radical melt grafting reactions, the conventional and comonomer-containing systems. In the grafted GMA, in the conventional system (EPR-g-GMA(CONV)), the methylene protons of the GMA were found to be sensitive to tetrad configurational sequences and the results showed that 56% of the GMA sequence in the graft is in atactic configuration and 42% is in syndiotactic configuration whereas the poly-GMA was predominantly syndiotactic. The differences in the microstructures of the graft in the conventional EPR-g-GMA(CONV) and the DVB-containing (EPR-g-GMA(DVB)) systems is also reported (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present experimental results on the performance of a series of coated, D-shaped optical fiber sensors that display high spectral sensitivities to external refractive index. Sensitivity to the chosen index regime and coupling of the fiber core mode to the surface plasmon resonance (SPR) is enhanced by using specific materials as part of a multi-layered coating. We present strong evidence that this effect is enhanced by post ultraviolet radiation of the lamellar coating that results in the formation of a nano-scale surface relief corrugation structure, which generates an index perturbation within the fiber core that in turn enhances the coupling. We have found reasonable agreement when we modeling the fiber device. It was found that the SPR devices operate in air with high coupling efficiency in excess of 40 dB with spectral sensitivities that outperform a typical long period grating, with one device yielding a wavelength spectral sensitivity of 12000 nm/RIU in the important aqueous index regime. The devices generate SPRs over a very large wavelength range, (visible to 2 mu m) by alternating the polarization state of the illuminating light.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production and characterization of narrow bandwidth fiber Bragg gratings (FBGs) in different spectral regions using polymer optical fibers (POFs) is reported. Narrow bandwidth FBGs are increasingly important for POF transmission systems, WDM technology and sensing applications. Long FBGs with resonance wavelength around 600-nm, 850-nm and 1550-nm in several types of polymer optical fibers were inscribed using a scanning technique with a short optical path. The technique allowed the inscription in relative short periods of time. The obtained 3-dB bandwidth varies from 0.22 down to 0.045 nm considering a Bragg grating length between 10 and 25-mm, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production and characterization of narrow bandwidth fiber Bragg gratings (FBGs) in different spectral regions using polymer optical fibers (POFs) is reported. Narrow bandwidth FBGs are increasingly important for POF transmission systems, WDM technology and sensing applications. Long FBGs with resonance wavelength around 600-nm, 850-nm and 1550-nm in several types of polymer optical fibers were inscribed using a scanning technique with a short optical path. The technique allowed the inscription in relative short periods of time. The obtained 3-dB bandwidth varies from 0.22 down to 0.045 nm considering a Bragg grating length between 10 and 25-mm, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fabrication and characterization of long-period gratings (LPGs) in fiber tapers is presented alongside supporting theory. The devices possess a high sensitivity to the index of aqueous solutions due to an observed spectral bifurcation effect, yielding a limiting index resolution of ±8.5 × 10-5 for solutions with an index in the range 1.330-1.335. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production and characterization of narrow bandwidth fiber Bragg gratings (FBGs) in different spectral regions using polymer optical fibers (POFs) is reported. Narrow bandwidth FBGs are increasingly important for POF transmission systems, WDM technology and sensing applications. Long FBGs with resonance wavelength around 600-nm, 850-nm and 1550-nm in several types of polymer optical fibers were inscribed using a scanning technique with a short optical path. The technique allowed the inscription in relative short periods of time. The obtained 3-dB bandwidth varies from 0.22 down to 0.045 nm considering a Bragg grating length between 10 and 25-mm, respectively. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In-fiber microchannels were fabricated directly in standard single mode fiber using the femtosecond laser inscribe and etch technique. This method of creating in-fiber microchannels offers great versatility since it allows complex three dimensional structures to be inscribed and then etched with hydrofluoric acid. Four in-fiber microchannel designs were experimentally investigated using this technique. Device characteristics were evaluated through monitoring the spectral change while inserting index matching oils into each microchannel - a R.I. sensitivity up to 1.55 dB/RIU was achieved. Furthermore, a simple Fabry-Pérot based refractometer with a R.I. sensitivity of 2.75 nm/RIU was also demonstrated. © 2014 SPIE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In-fiber microchannels were fabricated directly in standard single mode fiber using the femtosecond laser inscribe and etch technique. This method of creating in-fiber microchannels offers great versatility, since it allows complex three-dimensional structures to be inscribed and then preferentially etched with hydrofluoric acid. In addition, inscription does not require a photosensitive fiber; the modification is induced through nonlinear processes triggered by an ultrashort laser pulse. Four in-fiber microchannel designs were experimentally investigated using this technique - microhole, microslot channel along the core, microslot channel perpendicular to the core and helical channel around the core. Each device design was evaluated through monitoring the optical spectral change while inserting a range of index matching oils into each microchannel; an R.I. sensitivity up to 1.55 dB/RIU was achieved in these initial tests. Furthermore, an all femtosecond laser inscribed Fabry-Pérot-based refractometer with an R.I. sensitivity of 2.75 nm/RIU was also demonstrated. The Fabry-Pérot refractometer was formed by positioning a microchannel between two femtosecond laser inscribed point-by-point fiber Bragg gratings.