77 resultados para Shah Alam
em Aston University Research Archive
Resumo:
Previously, quality of formulations information provided for oral medications used in paediatric clinical trials published in 10 highly cited journals between 2002 and 2004 raised concerns. This short report explores if there was any subsequent improvement on how the formulations used in trials involving children
Resumo:
PURPOSE: To perform advanced analysis of the corneal deformation response to air pressure in keratoconics compared with age- and sex-matched controls. METHODS: The ocular response analyzer was used to measure the air pressure-corneal deformation relationship of 37 patients with keratoconus and 37 age (mean 36 ± 10 years)- and sex-matched controls with healthy corneas. Four repeat air pressure-corneal deformation profiles were averaged, and 42 separate parameters relating to each element of the profiles were extracted. Corneal topography and pachymetry were performed with the Orbscan II. The severity of the keratoconus was graded based on a single metric derived from anterior corneal curvatures, difference in astigmatism in each meridian, anterior best-fit sphere, and posterior best-fit sphere. RESULTS: Most of the biomechanical characteristics of keratoconic eyes were significantly different from normal eyes (P <0.001), especially during the initial corneal applanation. With increasing keratoconus severity, the cornea was thinner (r = -0.407, P <0.001), the speed of corneal concave deformation past applanation was quicker (dive; r = -0.314, P = 0.01), and the tear film index was lower (r = -0.319, P = 0.01). The variance in keratoconus severity could be accounted for by the corneal curvature and central corneal thickness (r = 0.80) with biomechanical characteristics contributing an additional 4% (total r = 0.84). The area under the receiver operating characteristic curve was 0.919 ± 0.025 for keratometry alone, 0.965 ± 0.014 with the addition of pachymetry, and 0.972 ± 0.012 combined with ocular response analyzer biomechanical parameters. CONCLUSIONS: Characteristics of the air pressure-corneal deformation profile are more affected by keratoconus than the traditionally extracted corneal hysteresis and corneal resistance factors. These biomechanical metrics slightly improved the detection and severity prediction of keratoconus above traditional keratometric and pachymetric assessment of corneal shape.
Resumo:
Cataract surgery is a technique described since recorded history, yet it has greatly evolved only in the latter half of the past century. The development of the intraocular lens and phacoemulsification as a technique for cataract removal could be considered as the two most significant strides that have been made in this surgical field. This review takes a comprehensive look at all aspects of cataract surgery, starting from patient selection through the process of consent, anaesthesia, biometry, lens power calculation, refractive targeting, phacoemulsification, choice of intraocular lens and management of complications, such as posterior capsular opacification, as well as future developments. As the most common ophthalmic surgery and with the expanding range of intraocular lens options, optometrists have an important and growing role in managing patients with cataract.
Resumo:
PURPOSE: To examine the effect of uncorrected astigmatism in older adults. SETTING: University Vision Clinic METHOD: Twenty-one healthy presbyopes, aged 58.9±2.8 years, had astigmatism of 0.0 to -4.0 x 90?DC and -3.0DC of cylinder at 90?, 180? and 45? induced with spectacle lenses, with the mean spherical equivalent compensated to plano, in random order. Visual acuity was assessed binocularly using a computerised test chart at 95%, 50% and 10% contrast. Near acuity and reading speed were measured using standardised reading texts. Light scatter was quantified with the cQuant and driving reaction times with a computer simulator. Finally visual clarity of a mobile phone and computer screen was subjectively rated. RESULTS: Distance visual acuity decreased with increasing uncorrected astigmatic power (F=174.50, p<0.001) and was reduced at lower contrasts (F=170.77, p<0.001). Near visual acuity and reading speed also decreased with increasing uncorrected astigmatism power (p<0.001). Light scatter was not significantly affected by uncorrected astigmatism (p>0.05), but the reliability and variability of measurements decreased with increasing uncorrected astigmatic power (p<0.05). Driving simulator performance was also unaffected by uncorrected astigmatism (p>0.05), but subjective rating of clarity decreased with increasing uncorrected astigmatic power (p<0.001). Uncorrected astigmatism at 45? or 180? orientation resulted in a worse distance and near visual acuity, and subjective rated clarity than 90? orientation (p<0.05). CONCLUSION: Uncorrected astigmatism, even as low as 1.0DC, causes a significant burden on a patient’s vision. If left uncorrected, this could impact significantly on their independence, quality of life and wellbeing.
Resumo:
Purpose: To describe the methodology, sampling strategy and preliminary results for the Aston Eye Study (AES), a cross-sectional study to determine the prevalence of refractive error and its associated ocular biometry in a large multi-racial sample of school children from the metropolitan area of Birmingham, England. Methods: A target sample of 1700 children aged 6–7 years and 1200 aged 12–13 years is being selected from Birmingham schools selected randomly with stratification by area deprivation index (a measure of socio-economic status). Schools with pupils predominantly (>70%) from a single race are excluded. Sample size calculations account for the likely participation rate and the clustering of individuals within schools. Procedures involve standardised protocols to allow for comparison with international population-based data. Visual acuity, non-contact ocular biometry (axial length, corneal radius of curvature and anterior chamber depth) and cycloplegic autorefraction are measured in both eyes. Distance and near oculomotor balance, height and weight are also assessed. Questionnaires for parents and older children will allow the influence of environmental factors on refractive error to be examined. Results: Recruitment and data collection are ongoing (currently N = 655). Preliminary cross-sectional data on 213 South Asian, 44 black African Caribbean and 70 white European children aged 6–7 years and 114 South Asian, 40 black African Caribbean and 115 white European children aged 12–13 years found myopia prevalence of 9.4% and 29.4% for the two age groups respectively. A more negative mean spherical equivalent refraction (SER) was observed in older children (-0.21 D vs +0.87 D). Ethnic differences in myopia prevalence are emerging with South Asian children having higher levels than white European children 36.8% vs 18.6% (for the older children). Axial length, corneal radius of curvature and anterior chamber depth were normally distributed, while SER was leptokurtic (p < 0.001) with a slight negative skew. Conclusions: The AES will allow ethnic differences in the ocular characteristics of children from a large metropolitan area of the UK to be examined. The findings to date indicate the emergence of higher levels of myopia by early adolescence in second and third generation British South Asians, compared to white European children. The continuation of the AES will allow the early determinants of these ethnic differences to be studied.
Resumo:
Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was
Resumo:
Release of cytochrome c from mitochondria is a major event during apoptosis. Released cytochrome c has been shown to activate caspase-dependent apoptotic signals. In this report, we provide evidence for a novel role of cytochrome c in caspase-independent nuclear apoptosis. We showed that cytochrome c, released from mitochondria upon apoptosis induction, gradually accumulates in the nucleus as evidenced by both immunofluorescence and subcellular fractionation. Parallel to nuclear accumulation of cytochrome c, acetylated histone H2A, but not unmodified H2A, was released from the nucleus to the cytoplasm. Addition of purified cytochrome c to isolated nuclei recapitulated the preferential release of acetylated, but not deacetylated, histone H2A. Cytochrome c was also found to induce chromatin condensation. These results suggest that the nuclear accumulation of cytochrome c may be directly involved in the remodeling of chromatin. Our results provide evidence of a novel role for cytochrome c in inducing nuclear apoptosis.
Resumo:
Purpose To develop a standardized questionnaire of near visual function and satisfaction to complement visual function evaluations of presbyopic corrections. Setting Eye Clinic, School of Life and Health Sciences, Aston University, Midland Eye Institute and Solihull Hospital, Birmingham, United Kingdom. Design Questionnaire development. Methods A preliminary 26-item questionnaire of previously used near visual function items was completed by patients with monofocal intraocular lenses (IOLs), multifocal IOLs, accommodating IOLs, multifocal contact lenses, or varifocal spectacles. Rasch analysis was used for item reduction, after which internal and test–retest reliabilities were determined. Construct validity was determined by correlating the resulting Near Activity Visual Questionnaire (NAVQ) scores with near visual acuity and critical print size (CPS), which was measured using the Minnesota Low Vision Reading Test chart. Discrimination ability was assessed through receiver-operating characteristic (ROC) curve analysis. Results One hundred fifty patients completed the questionnaire. Item reduction resulted in a 10-item NAVQ with excellent separation (2.92), internal consistency (Cronbach a = 0.95), and test–retest reliability (intraclass correlation coefficient = 0.72). Correlations of questionnaire scores with near visual acuity (r = 0.32) and CPS (r = 0.27) provided evidence of validity, and discrimination ability was excellent (area under ROC curve = 0.91). Conclusion Results show the NAVQ is a reliable, valid instrument that can be incorporated into the evaluation of presbyopic corrections.
Resumo:
Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia.
Resumo:
To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.
Resumo:
The design and synthesis of safe efficient non-viral vectors for gene delivery has attracted significant attention in recent years due primarily to the severe side-effect profile reported with the use of their viral counterparts. Previous experiments have revealed that the strong interaction between the carriers and nucleic acid may well hinder the release of the gene from the complex in the cytosol adversely affecting transfection efficiency. However, incorporating reducible disulfide bonds within the delivery systems themselves which are then cleaved in the glutathione-rich intracellular environment may help in solving this puzzle. This review focuses on recent development of these reducible carriers. The biological rationale and approaches to the synthesis of reducible vectors are discussed in detail. The in vitro and in vivo evaluations of reducible carriers are also summarized and it is evident that they offer a promising approach in non-viral gene delivery system design.
Resumo:
Purpose: To determine the most appropriate analysis technique for the differentiation of multifocal intraocular lens (MIOL) designs using defocus curve assessment of visual capability.Methods:Four groups of fifteen subjects were implanted bilaterally with either monofocal intraocular lenses, refractive MIOLs, diffractive MIOLs, or a combination of refractive and diffractive MIOLs. Defocus curves between -5.0D and +1.5D were evaluated using an absolute and relative depth-of-focus method, the direct comparison method and a new 'Area-of-focus' metric. The results were correlated with a subjective perception of near and intermediate vision. Results:Neither depth-of-focus method of analysis were sensitive enough to differentiate between MIOL groups (p>0.05). The direct comparison method indicated that the refractive MIOL group performed better at +1.00, -1.00 and -1.50 D and worse at -3.00, -3.50, -4.00 and -5.00D compared to the diffractive MIOL group (p
Resumo:
Investigations of relationships between the specific personality variable, locus of control (LOC, Rotter, 1966) and driver behaviour or accidents have returned contrasting results. Review suggests dependence on gender or experience characteristics of participants, suggesting these factors interact with LOC to influence driving. Relationships were investigated in terms of influence on the eight driving styles of the Multidimensional Driving Style Inventory (MDSI, Taubman-Ben-Ari, Mikulincer & Gillarth, 2004) in young drivers (18-29 years). Gender and LOC differences in driving styles previously related to accidents were proposed. It was also proposed that driving experience influences driving style, and LOC influences effect of driving experience. Gender differences were found for dissociative, anxious, patient, risky, angry and high velocity styles. Women had more external LOC than men, and driver stress styles increased with more external LOC, but reduced with increased driving experience, but so did patient style. High velocity style increased with experience. Controlling for LOC revealed important gender differences in effect of experience: positive effects for men (reducing angry and high velocity, increasing carefulness) and negative effects for women (increasing angry and higher velocity, reducing carefulness). Findings suggest negative influence of high internal LOC on young men in terms of its interaction with experience.
Resumo:
Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.