25 resultados para Sewage sludge
em Aston University Research Archive
Resumo:
Sewage sludge was pyrolysed with 40% mixed wood, 40% rapeseed and 40% straw. The reason for the mixture of different biomass is to investigate the impact of co-pyrolysis on the upper phase of bio-oil in terms of changes to composition, elemental analysis, viscosity, water content, pH, higher heating value and acid number that could impact on their applications. The biomass was pyrolysed in a laboratory at 450 °C and bio-oil was collected from two cooling traps. The bio-oil obtained from co-pyrolysis of sewage sludge with wood, rapeseed and straw was analysed for composition using the gas chromatography mass spectrometry. The upper phase from the co-pyrolysis process was also characterised for ultimate analysis, higher heating values, water content, viscosity, pH and acid number. There was an increase in the amount of upper phase produced with co-pyrolysis of 40% rapeseed. It was also found that the upper phase from sewage sludge with mixed wood has the highest viscosity, acid number and lowest pH. The bio-oil containing 40% straw was found to have a pH of 6.5 with a very low acid number while the 40% rapeseed was found to have no acid number. Sewage sludge with 40% rapeseed was found to have the highest energy content of 34.8 MJ/kg, 40% straw has 32.5 MJ/kg while the 40% mixed wood pyrolysis oil has the lowest energy content of 31.3 MJ/kg. The 40% rapeseed fraction was found to have the highest water content of 8.2% compared to other fractions.
Resumo:
The use of the pyrolysis process to obtain valuable products from biomass is amongst the technologies being investigated as a source for renewable energy. The pyrolysis process yields products such as biochar, bio-oil and non condensable gases. The main objective of this project is to increase energy recovery from sewage sludge by utilising the intermediate pyrolysis process. The intermediate pyrolysis has a residence time ranging from 5 to 10 minutes. The main product yields from sewage sludge pyrolysis are 50 wt% biochar, 40 wt% bio-oil and 10 wt% non condensable gases. The project was carried out on a pilot plant scale reactor with a load capacity of 20 kg/h. This enabled a high yield of biochar and bio-oil. The characterisation of the products indicated that the organic phase of the bio-oil had good fuel properties such as having high energy content of 39 MJ/kg, low acid number of 21.5, high flash point of 150 and viscosity of 35 cSt. An increase in pyrolysis experiments enabled large quantities of pyrolysis oil production. Co-pyrolysis of sewage sludge was carried out on laboratory scale with mixed wood, rapeseed and straw. It found that there was an increase in bio-oil quantity with rapeseed while co-pyrolysis with wood helped to mask the smell of the sludge pyrolysis oil. Engine test were successfully carried out in an old Lister engine with pyrolysis oil fractions of 30% and 50% blended with biodiesel. This indicates that these pyrolysis oil fractions can be used in similar engine types without any problems however long term effects in ordinary engines are unknown. An economic evaluation was carried out about the implementation of the intermediate pyrolysis process for electricity production in a CHP using the pyrolysis oil. The prices of electricity per kWh were found to be very high.
Resumo:
This paper studies the characteristics of blends of biodiesel and a new type of SSPO (sewage sludge derived intermediate pyrolysis oil) in various ratios, and evaluates the application of such blends in an unmodified Lister diesel engine. The engine performance and exhaust emissions were investigated and compared to those of diesel and biodiesel. The engine injectors were inspected and tested after the experiment. The SSPO-biodiesel blends were found to have comparable heating values to biodiesel, but relatively high acidity and carbon residue. The diesel engine has operated with a 30/70 SSPO-biodiesel blend and a 50/50 blend for up to 10h and there was no apparent deterioration in operation observed. It is concluded that with 30% SSPO, the engine gives better overall performance and fuel consumption than with 50% SSPO. The exhaust temperatures of 30% SSPO and 50% SSPO are similar, but 30% SSPO gives relatively lower NO emission than 50% SSPO. The CO and smoke emissions are lower with 50% SSPO than with 30% SSPO. The injectors of the engine operated with SSPO blends were found to have heavy carbon deposition and noticeably reduced opening pressure, which may lead to deteriorated engine performance and exhaust emissions in extended operation. © 2013 Elsevier Ltd.
Resumo:
The stability of the oil phase obtained from intermediate pyrolysis process was used for this investigation. The analysis was based on standard methods of determining kinematic viscosity, gas - chromatography / mass - spectrometry for compositional changes, FT-IR for functional group, Karl Fischer titration for water content and bomb calorimeter for higher heaating values. The methods were used to determine changes that occurred during ageing. The temperatures used for thermal testing were 60 °C and 80 °C for the periods of 72 and 168 h. Methanol and biodiesel were used as solvents for the analysis. The bio-oil samples contained 10 % methanol, 10 % Biodiesel, 20 % Biodiesel and unstabilised pyrolysis oil. The tests carried out at 80 °C showed drastic changes compared to those at 60 °C. The bio-oil samples containing 20 % biodiesel proved to be more stable than those with 10 % methanol. The unstabilised pyrolysis oil showed the greatest changes in viscosity, composition change and highest increase in water content. The measurement of kinematic viscosity and gas chromatograph mass spectrometry were found to be more reliable for predicting the ageing process.
Resumo:
This paper studies the characteristics of intermediate pyrolysis oils derived from sewage sludge and de-inking sludge (a paper industry residue), with a view to their use as fuels in a diesel engine. The feedstocks were dried and pelletised, then pyrolysed in the Pyroformer intermediate pyrolysis system. The organic fraction of the oils was separated from the aqueous phase and characterised. This included elemental and compositional analysis, heating value, cetane index, density, viscosity, surface tension, flash point, total acid number, lubricity, copper corrosion, water, carbon residue and ash content. Most of these results are compared with commercial diesel and biodiesel. Both pyrolysis oils have high carbon and hydrogen contents and their higher heating values compare well with biodiesel. The water content of the pyrolysis oils is reasonable and the flash point is found to be high. Both pyrolysis oils have good lubricity, but show some corrosiveness. Cetane index is reduced, which may influence ignition. Also viscosity is increased, which may influence atomisation quality. Carbon residue and ash content are both high, indicating potential deposition problems. Compared with de-inking sludge pyrolysis oil (DSPO), sewage sludge pyrolysis oil (SSPO) has a higher heating value, but higher corrosiveness and viscosity. The conclusions are that both intermediate pyrolysis oils will be able to provide sufficient heat when used in diesel engine; however poor combustion and carbon deposition may be encountered. Blending of these pyrolysis oils with diesel or biodiesel could overcome these problems and is recommended for further investigation.
Resumo:
This study investigates the use of Pyroformer intermediate pyrolysis system to produce alternative diesel engines fuels (pyrolysis oil) from various biomass and waste feedstocks and the application of these pyrolysis oils in a diesel engine generating system for Combined Heat and Power (CHP) production. The pyrolysis oils were produced in a pilot-scale (20 kg/h) intermediate pyrolysis system. Comprehensive characterisations, with a view to use as engine fuels, were carried out on the sewage sludge and de-inking sludge derived pyrolysis oils. They were both found to be able to provide sufficient heat for fuelling a diesel engine. The pyrolysis oils also presented poor combustibility and high carbon deposition, but these problems could be mitigated by means of blending the pyrolysis oils with biodiesel (derived from waste cooking oil). The blends of SSPO (sewage sludge pyrolysis oil) and biodiesel (30/70 and 50/50 in volumetric ratios) were tested in a 15 kWe Lister type stationary generating system for up to 10 hours. There was no apparent deterioration observed in engine operation. With 30% SSPO blended into biodiesel, the engine presents better overall performance (electric efficiency), fuel consumption, and overall exhaust emissions than with 50% SSPO blend. An overall system analysis was carried out on a proposed integrated Pyroformer-CHP system. Combined with real experimental results, this was used for evaluating the costs for producing heat and power and char from wood pellets and sewage sludge. It is concluded that the overall system efficiencies for both types of plant can be over 40%; however the integrated CHP system is not economically viable. This is due to extraordinary project capital investment required.
Resumo:
The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.
Resumo:
The treatment of effluents produced during the manufacture of metallurgical coke is normally carried out using the activated sludge process. The efficiency of activated sludges in purifying coke oven effluent depends largely on the maintenance of species of micro-organisms which destroy thiocyanate. The composition, production, toxicity and treatment of coke oven effluent at Corby steelworks are described. A review is presented which follows the progress made towards identifying and monitoring the species of bacteria which destroy thiocyanate in biological treatment plants purifying coke oven effluents. In the present study a search for bacteria capable of destroying thiocyanate led to the isolation of a species of bacteria, identified as Pseudomonas putida, which destroyed thiocyanate in the presence of succinate; this species had not previously been reported to use thiocyanate. Washed cell suspensions of P. putida destroyed phenol and thiocyanate simultaneously and thiocyanate destruction was not suppressed by pyridine, aniline or catechol at the highest concentrations normally encountered in coke oven effluent. The isolate has been included, as N.C.I.B. 11198, in the National Collection of Industrial Bacteria, Torrey Research Station, Aberdeen. Three other isolates, identified as Achromobacter sp., Thiobacillus thioparus and T. denitrificans, were also confirmed to destroy thi.ocyanate. A technique has been developed for monitoring populations of different species of bacteria in activated sludges. Application of this technique to laboratory scale and full scale treatment plants at Corby showed that thiobacilli were usually not detected; thiobacilli were el~inated during the commissioning period of the full scale plant. However experiments using a laboratory scale plant indicated that during a period of three weeks an increase in the numbers of thiobacilli might have contributed to an improvement in plant performance. Factors which might have facilitated the development of thiobacilli are discussed. Large numbers of fluorescent pseudomonads capable of using thiocyanate were sometimes detected in the laboratory scale plant. The possibility is considered that catechol or other organic compounds in the feed-liquor might have stimulated fluorescent pseudmonads. Experiments using the laboratory scale plant confirmed that deteriorations in the efficiency of thiocyanate destruction were sometimes caused by bulking sludges, due to the excessive growth of fungal floes. Increased dilution of the coke oven effluent was a successful remedy to this difficulty. The optimum operating conditions recommended by the manufacturer of the full scale activated sludge plant at Corby are assessed and the role of bacterial monitoring in a programme of regular monitoring tests is discussed in relation to the operation of activated sludge plants treating coke oven effluents.
Resumo:
Pilot scale studies of high rate filtration were initiated to assess its potential as either a primary 'roughing' filter to alleviate the seasonal overloading of low rate filters on Hereford sewage treatment works - caused by wastes from cider production - or as a two stage high rate process to provide complete sewage treatment. Four mineral and four plastic primary filter media and two plastic secondary filter media were studied. The hydraulic loading applied to the primary plastic media (11.2 m3 /m3 .d) was twice that applied to the mineral media. The plastic media removed an average around 66 percent and the mineral media around 73 percent of the BOD applied when the 90 percentile BOD concentration was 563 mg/1. At a hydraulic loading of 4 m3 /m3 .d the secondary filters removed most of the POD from partially settled primary filter effluents, with one secondary effluent satisfying a 25 mg/1 BOD and 30 mg/1 SS standard. No significant degree of nitrification was achieved. Fungi dominated the biological film of the primary filters, with invertebrate grazers having little influence on film levels. Ponding did not arise, and modular media supported lower film levels than random-fill types. Secondary filter film levels were low, being dominated by bacteria. The biological loading applied to the filters was related to sludge dewaterability, with the most readily conditionable sludges produced by filters supporting heavy film. Sludges produced by random-fill media could be dewatered as readily as those produced by low rate filters treating the same sewage. Laboratory scale studies showed a relationship between log effluent BOD and nitrification achieved by biological filters. This relationship and the relationship between BOD load applied and removed observed in all filter media could he used to optimise operating conditions required in biological filters to achieve given effluent BOD and ammoniacal nitrogen standards.
Resumo:
A procedure has been developed which measures the settling velocity distribution of particles within a complete sewage sample. The development of the test method included observations of particle and liquid interaction using both synthetic media and sewage. Comparison studies with two other currently used settling velocity test procedures was undertaken. The method is suitable for use with either DWF or storm sewage. Information relating to the catchment characteristics of 35 No. wastewater treatment works was collected from the privatised water companies in England and Wales. 29 No. of these sites were used in an experimental programme to determine the settling velocity grading of 33 No. sewage samples. The collected data were analysed in an attempt to relate the settling velocity distribution to the characteristics of the contributing catchment. Statistical analysis of the catchment data and the measured settling velocity distributions was undertaken. A curve fitting exercise using an S-shaped curve which had the same physical characteristics as the settling velocity distributions was performed. None of these analyses found evidence that the settling velocity distribution of sewage had a significant relationship with the chosen catchment characteristics. The regression equations produced from the statistical analysis cannot be used to assist in the design of separation devices. However, a grading curve envelope was produced, the limits of which were clearly defined for the measured data set. There was no evidence of a relationship between settling velocity grading and the characteristics of the contributing catchment, particularly the catchment area. The present empirical approach to settling tank design cannot be improved upon at present by considering the variation in catchment parameters. This study has provided a basis for future research into the settling velocity measurement and should be of benefit to future workers within this field.
Resumo:
A methodology has been developed to measure the chemical constituents associated with the settling velocity fractions that comprise a wastewater settling velocity profile (SVP). 31 wastewater samples were collected from fifteen different catchments in England and Wales. For each catchment, settling velocity and associated chemical constituent profiles were determined. The results are mainly for Suspended Solids (SS), Chemical Oxygen Demand (COD), Phosphorus (P) and Total Kjeadahl Nitrogen (TKN), however these are supplemented by the results from 5 events for a suite of heavy metals. COD, P, Hg, Mn and Pb were found to be predominantly associated with the solid phase and TKN, Al, Cu and Fe with the liquor phase of the wastewater samples. The results in the thesis are expressed as mass of pollutant (g) per mass total SS (kg). COD and P were found to be mainly associated with the sinkers and had a particular affinity for solids with settling velocities in the range 0.9-9.03mm/sec. TKN was mainly associated with the soluble phase, however of the solids that did settle, a peak was found to be associated within the settling velocity range 0.9-9.03mm/sec. The relationships identified for COD and P were generally found to be unaffected by flow conditions and catchment characteristics. However, TKN was found to be affected by catchment type. Data on the distribution of heavy metals was limited, and no specific relationships with solids were identified. 16 mean pollutant profiles are presented in the thesis. Presentation of the data in this form will enable the results to be of use in the design of sedimentation devices to predict removal efficiencies for solids and associated pollutants. The findings of the research may also be applied to modelling tools to provide further characteristics on the solids that are modelled than is currently used. This would enhance the overall performance of tools used in integrated catchment modelling.