9 resultados para Sensation
em Aston University Research Archive
Resumo:
The rectum has a unique physiological role as a sensory organ and differs in its afferent innervation from other gut organs that do not normally mediate conscious sensation. We compared the central processing of human esophageal, duodenal, and rectal sensation using cortical evoked potentials (CEP) in 10 healthy volunteers (age range 21-34 yr). Esophageal and duodenal CEP had similar morphology in all subjects, whereas rectal CEP had two different but reproducible morphologies. The rectal CEP latency to the first component P1 (69 ms) was shorter than both duodenal (123 ms; P = 0.008) and esophageal CEP latencies (106 ms; P = 0.004). The duodenal CEP amplitude of the P1-N1 component (5.0 µV) was smaller than that of the corresponding esophageal component (5.7 µV; P = 0.04) but similar to that of the corresponding rectal component (6.5 µV; P = 0.25). This suggests that rectal sensation is either mediated by faster-conducting afferent pathways or that there is a difference in the orientation or volume of cortical neurons representing the different gut organs. In conclusion, the physiological and anatomic differences between gut organs are reflected in differences in the characteristics of their afferent pathways and cortical processing.
Resumo:
It has been suggested that the deleterious effect of contrast reversal on visual recognition is unique to faces, not objects. Here we show from priming, supervised category learning, and generalization that there is no such thing as general invariance of recognition of non-face objects against contrast reversal and, likewise, changes in direction of illumination. However, when recognition varies with rendering conditions, invariance may be restored, and effects of continuous learning may be reduced, by providing prior object knowledge from active sensation. Our findings suggest that the degree of contrast invariance achieved reflects functional characteristics of object representations learned in a task-dependent fashion.
Resumo:
Jackson (2005) developed a hybrid model of personality and learning, known as the learning styles profiler (LSP) which was designed to span biological, socio-cognitive, and experiential research foci of personality and learning research. The hybrid model argues that functional and dysfunctional learning outcomes can be best understood in terms of how cognitions and experiences control, discipline, and re-express the biologically based scale of sensation-seeking. In two studies with part-time workers undertaking tertiary education (N=137 and 58), established models of approach and avoidance from each of the three different research foci were compared with Jackson's hybrid model in their predictiveness of leadership, work, and university outcomes using self-report and supervisor ratings. Results showed that the hybrid model was generally optimal and, as hypothesized, that goal orientation was a mediator of sensation-seeking on outcomes (work performance, university performance, leader behaviours, and counterproductive work behaviour). Our studies suggest that the hybrid model has considerable promise as a predictor of work and educational outcomes as well as dysfunctional outcomes.
Resumo:
OBJECTIVES: As visceral afferents from different regions of the gastrointestinal tract converge at the level of the spinal cord, we hypothesized that sensitization of one gut organ would induce visceral hypersensitivity in another gut organ, remote to the sensitizing stimulus. METHODS: Protocol 1: Eight healthy male volunteers, age 30 +/- 8.2 yr, underwent three studies on different days. Esophageal pain thresholds (PT) were recorded at 10-min intervals prior to and for 2 h following a 30-min duodenal infusion of either 0.15 M hydrochloric acid (HCl), saline, or no infusion. Five subjects repeated the study to demonstrate reproducibility. Protocol 2: Esophageal evoked potentials (EEP) were studied in six subjects on two occasions prior to and 1 h after a 30-min duodenal infusion of 0.15 M HCl or saline. RESULTS: Protocol 1: After acid infusion, there were reproducible reductions in esophageal PT (ICC = 0.88), which were maximal at 110 min (15.05 +/- 2.25 mA) (p < 0.002). Following saline infusion there was an increase in esophageal PT (ICC = 0.71), which was similar to the no-infusion condition (6.21 +/- 1.54 mA vs 8.5 + 7.6 mA; p > 0.05). Protocol 2: Esophageal sensation scores increased (p= 0.02) after acid, but not after saline infusion (p= 0.1). A comparison of the latencies of EEP components prior to and following acid and saline infusion revealed a reduction in the N1 (p= 0.02) and P2 components (p= 0.04). CONCLUSION: This study provides the first objective evidence that duodenal acidification can induce esophageal hypersensitivity associated with changes in sensitivity of the central visceral pain pathway. As the esophagus was remote from the sensitizing stimulus, central sensitization of spinal dorsal horn neurons is likely to have contributed to these changes.
Resumo:
Contact lenses have become a popular method of vision correction for millions of people globally. As with all devices designed for use within the body, interactions occur between the implanted material and the surrounding biological fluid. A common complaint of lens wearers is that they often experience symptoms of dry eye whilst wearing lenses. This sensation is often heightened towards the end of the day. Through the course of this study, various analytical techniques have been utilised including one dimensional electrophoresis and Western Blotting to study the protein profiles of tear samples. By studying the tears of non-contact lens wearers, it was possible to analyse what could be considered normal, healthy, individuals. A clinical study was also undertaken which followed a population of individuals from the neophyte stage to one whereby they were accustomed lens wearers. Tears were monitored at regular intervals throughout the course of this study and worn contact lenses were also analysed for proteins that had been deposited both on and within the lens. Contact lenses disrupt the tear film in a physical manner by their very presence. They are also thought to cause the normal protein profile to deviate from what would be considered normal. The tear film deposits proteins and lipids onto and within the lens. The lens may therefore be depriving the tear film of certain necessary components. The ultimate aim of this thesis was to discover how, and to what extent, lenses affected tear proteins and if there were any proteins in the tear fluid that had the potential to be used as biochemical markers. Should this be achievable it may be possible to identify those individuals who were more likely to become intolerant lens wearers. This study followed the changes taking place to the tear film as an effect of wearing contact lenses. Twenty-eight patients wore two different types of silicone hydrogel lenses in both a daily wear and a continuous wear regime. The tear protein profiles of the lens-wearers were compared with a control group of non-lens wearing individuals. The considerable amount of data that was generated enabled the clearly observable changes to the four main tear proteins to be monitored.
Resumo:
Dry eye is a common yet complex condition. Intrinsic and extrinsic factors can cause dysfunction of the lids, lacrimal glands, meibomian glands, ocular surface cells, or neural network. These problems would ultimately be expressed at the tear film-ocular surface interface. The manifestations of these problems are experienced as symptoms such as grittiness, discomfort, burning sensation, hyperemia, and secondary epiphora in some cases. Accurate investigation of dry eye is crucial to correct management of the condition. Techniques can be classed according to their investigation of tear production, tear stability, and surface damage (including histological tests). The application, validity, reliability, compatibility, protocols, and indications for these are important. The use of a diagnostic algorithm may lead to more accurate diagnosis and management. The lack of correlation between signs and symptoms seems to favor tear film osmolarity, an objective biomarker, as the best current clue to correct diagnosis.
Resumo:
Gamma oscillations have previously been linked to pain perception and it has been hypothesised that they may have a potential role in encoding pain intensity. Stimulus response experiments have reported an increase in activity in the primary somatosensory cortex (SI) with increasing stimulus intensity, but the specific role of oscillatory dynamics in this change in activation remains unclear. In this study, Magnetoencephalography (MEG) was used to investigate the changes in cortical oscillations during 4 different intensities of a train of electrical stimuli to the right index finger, ranging from low sensation to strong pain. In those participants showing changes in evoked oscillatory gamma in SI during stimulation, the strength of the gamma power was found to increase with increasing stimulus intensity at both pain and sub-pain thresholds. These results suggest that evoked gamma oscillations in SI are not specific to pain but may have a role in encoding somatosensory stimulus intensity. © 2013 Rossiter, Worthen, Witton, Hall and Furlong.
Resumo:
Asthenopia, or visual fatigue, is a frequent complaint from observers of stereoscopic three-dimensional displays. It has been proposed that asthenopia is a consequence of anomalous oculomotor responses generated by conflict between accommodative and convergence stimuli. The hypothesis was examined by measuring accommodation and convergence continuously with a Shin-Nippon SRW5000 infrared autorefractor and a limbus tracking device. Subjects viewed a high contrast Maltese Cross target at three levels of Gaussian filter target blur under conditions of relatively low- and high-conflict between accommodation and convergence stimuli, the latter inducing the sensation of stereopsis. Under the low-conflict conditions accommodation was stable, but convergence-driven accommodation was dominant when the target was extremely blurred. Under the high-conflict conditions the role of convergence-driven accommodation increased systematically with the degree of target blur. It is proposed that defocus-driven accommodation becomes weak when the target comprises low spatial frequency components. Large accommodative overshoots to step stimuli that are not blurred or only mildly blurred were consistently observed and are attributed to the initial accommodative response being convergence-driven. Whereas the possibility that high-conflict conditions are a cause of asthenopia has been previously reported, this is the first evidence that they specifically affect accommodative responses while viewing stereoscopic displays. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
Our goal here is a more complete understanding of how information about luminance contrast is encoded and used by the binocular visual system. In two-interval forced-choice experiments we assessed observers' ability to discriminate changes in contrast that could be an increase or decrease of contrast in one or both eyes, or an increase in one eye coupled with a decrease in the other (termed IncDec). The base or pedestal contrasts were either in-phase or out-of-phase in the two eyes. The opposed changes in the IncDec condition did not cancel each other out, implying that along with binocular summation, information is also available from mechanisms that do not sum the two eyes' inputs. These might be monocular mechanisms. With a binocular pedestal, monocular increments of contrast were much easier to see than monocular decrements. These findings suggest that there are separate binocular (B) and monocular (L,R) channels, but only the largest of the three responses, max(L,B,R), is available to perception and decision. Results from contrast discrimination and contrast matching tasks were described very accurately by this model. Stimuli, data, and model responses can all be visualized in a common binocular contrast space, allowing a more direct comparison between models and data. Some results with out-of-phase pedestals were not accounted for by the max model of contrast coding, but were well explained by an extended model in which gratings of opposite polarity create the sensation of lustre. Observers can discriminate changes in lustre alongside changes in contrast.