Resumo:
With the increasing use of digital computers for data acquisition and digital process control, frequency domain transducers have become very attractive due to their virtual digital output. Essentially they are electrically maintained oscillators where the sensor is the controlling resonator.They are designed to make the frequency a function of the physical parameter being measured. Because of their high quality factor, mechanical resonators give very good frequency stability and are widely used as sensors. For this work symmetrical mechanical resonators such as the tuning fork were considered, to be the most promising. These are dynamically clamped and can be designed to have extensive regions where no vibrations occur.This enables the resonators to be robustly mounted in a way convenient for various applications. Designs for the measurement of fluid density and tension have been produced. The principle of the design of the resonator for fluid density measurement is a thin gap (trapping a lamina of fluid) between its two members which vibrate in antiphase.An analysis of the inter action between this resonator and the fluid lamina has carried out.In gases narrow gaps are needed for a good sensitivity and the use of the material fused quartz, because of its low density and very low temperature coefficient, is ideally suitable. In liquids an adequate sensitivity is achieved even with a wide lamina gap. Practical designs of such transducers have been evolved. The accuracy for liquid measurements is better than 1%. For gases it was found that, in air, a change of atmospheric pressure of 0.3% could be detected. In constructing a tension transducer using such a mechanical sensor as a wire or a beam, major difficulties are encountered in making an efficient clamping arrangement for the sensor. The use of dynamically clamped beams has been found to overcome the problem and this is the basis of the transducer investigated.
Resumo:
The replacement of diesel fuel by ultra-carbofluids was perceived to offer the potential to decrease the emissions of environmental pollutants such as carbon dioxide, carbon monoxide, hydrocarbons (HC's) and smoke. Such ultracarbofluids consist of a suspension of coal in fuel oil and water generally in the ratio of 5: 3: 2 plus a small amount of stabilising additive. The literature relating to the economies of coal and fuel oil production, and the production and properties of charcoal and vegetable oils has been critically reviewed. The potential use of charcoal and vegetable oils as replacements for coal and fuel oil are discussed. An experimental investigation was undertaken using novel bio-ultracarbofluid formulations. These differed from an ultracarbofluid by having bio-renewable charcoal and vegetable oil in place of coal and fuel oil. Tests were made with a Lister-Petter 600cc 2-cylinder, 4-stroke diesel engine fitted with a Heenan-Froude DPX 1 water brake dynamometer to measure brake power output, and Mexa-321E and Mexa-211E analysers to measure exhaust pollutants. Measurements were made of engine brake power output, carbon dioxide, carbon monoxide, hydrocarbons and smoke emissions over the speed range 1000 to 3000 rpm at 200 rpm intervals. The results were compared with those obtained with a standard diesel reference fuel. All the bio-ultracarbofluid formulations produced lower brake power outputs (i.e. 5.6% to 20.7% less brake power) but substantially improved exhaust emissions of CO2, CO, HC's and smoke. The major factor in the formulation was found to be the type and amount of charcoal; charcoal with a high volatile content (27.2%) and present at 30% by mass yielded the best results, i.e. only slightly lower brake power output and significantly lower exhaust pollutants.
Resumo:
Changes in the concentration of some constituents in women's saliva during the menstrual cycle were studied. Saliva was used because it is easier to collect than other body fluids and is continuously available for analysis. Glucose, the enzyme 17-Acetyl-D-glucosaminidase (NAG) and Calcium which are saliva constituents and belong to three different chemical groups were selected for the study. Several analytical techniques were investigated. The fluorometric assay procedure was found to be the best because of its specificity and sensitivity for the estimation of these constituents. resides the fluorametric method a spectrophotometric method was used in the NAG determination and an atomic absorption method in the calcium estimation. Glucose was estimated by an enzymatic method. This is based on the reaction of glucose with the enzymes glucose oxidase and peroxidase to yield hydrogen peroxide, which in turn oxidises a non-fluorescent substrate, p-hydroxyphenylacetic acid, to a highly fluorescent product. The saliva samples in this determination had to be centrifuged at high speed, heated in a boiling water bath, centrifuged again and then treated with a mixture of cation and anion resins to remove the substances that inhibited the enzyme system. In the determination of the NAG activity the saliva samples were diluted with citric acid/phosphate buffer, and then centrifuged at high speed. The assay was based on the enzymic hydrolysis of the non-fluorescent substrate 4-Methyl-umbelli1eryl-p-D-glucosaminide to the highly fluorescent 4-Methyl-umbelliferone• Calcium was estimated by a fluorometric procedure based upon the measurement of the fluorescence produced by the complex formed between calcein blue and calcium, at pH 9 - 13. From the results obtained from the analysis of saliva samples of several women it was found that glucose showed a significant increase in its level around the expected time of ovulation. This was found in seven cycles out of ten. Similar results were found with the enzyme NAG. No significant change in the calcium levels was observe& at any particular time of the cycle. The levels of the glucose, the activity of the enzyme NAG and the concentration of the calcium were found to change daily, and to differ from one subject to another and in the same subject from cycle to cycle. The increase observed it salivary glucose levels and the enzyme NAG activity could be monitored to predict the time of ovulation.
The compressive creep and load relaxation properties of a series of high aluminium zinc-based alloys
Resumo:
A new family of commercial zinc alloys designated as ZA8, ZA12, and ZA27 and high damping capacity alloys including Cosmal and Supercosmal and aluminium alloy LM25 were investigated for compressive creep and load relaxation behaviour under a series of temperatures and stresses. A compressive creep machine was designed to test the sand cast hollow cylindrical test specimens of these alloys. For each compressive creep experiment the variation of creep strain was presented in the form of graphs plotted as percentage of creep strain () versus time in seconds (s). In all cases, the curves showed the same general form of the creep curve, i.e. a primary creep stage, followed by a linear steady-state region (secondary creep). In general, it was observed that alloy ZA8 had the least primary creep among the commercial zinc-based alloys and ZA27 the greatest. The extent of primary creep increased with aluminium content to that of ZA27 then declined to Supercosmal. The overall creep strength of ZA27 was generally less than ZA8 and ZA12 but it showed better creep strength than ZA8 and ZA12 at high temperature and high stress. In high damping capacity alloys, Supercosmal had less primary creep and longer secondary creep regions and also had the lowest minimum creep rate among all the tested alloys. LM25 exhibited almost no creep at maximum temperature and stress used in this research work. Total creep elongation was shown to be well correlated using an empirical equation. Stress exponent and activation energies were calculated and found to be consistent with the creep mechanism of dislocation climb. The primary α and β phases in the as-cast structures decomposed to lamellar phases on cooling, with some particulates at dendrite edges and grain boundaries. Further breakdown into particulate bodies occurred during creep testing, and zinc bands developed at the highest test temperature of 160°C. The results of load relaxation testing showed that initially load loss proceeded rapidly and then deminished gradually with time. Load loss increased with temperature and almost all the curves approximated to a logarithmic decay of preload with time. ZA alloys exhibited almost the same load loss at lower temperature, but at 120°C ZA27 improved its relative performance with the passage of time. High damping capacity alloys and LM25 had much better resistance to load loss than ZA alloys and LM25 was found to be the best against load loss among these alloys. A preliminary equation was derived to correlate the retained load with time and temperature.