Aim: To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. Methods: EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) years). Measurements were made on two occasions separated by 1 year. Intrasession repeatability was assessed by repeating the measures after a 10 minute recovery period at the first visit. Distance visual acuity was measured with a logMAR chart, near visual acuity with a MNRead chart at 25 cm, contrast sensitivity with a Pelli-Robson chart, and the presence of central visual disturbance assessed with an Amsler grid. A questionnaire was used to assess self reported difficulties with glare recovery. Results: The average EMS recovery time was 11.0 (SD 8.9) seconds, decreasing by 1.6 (5.2) seconds on repeated measurement (p<0.05). EMS photostress recovery was not correlated with visual function measures or subjective difficulties with lights (p>0.05). EMS photostress recovery time did not predict those whose vision decreased over the following year compared with those among whom it remained stable. Conclusions: The EMS test is not a useful tool in determining the severity or progression of AMD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6±1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p<0.001), lens region (centre, mid-periphery and edge: p<0.05) and there was interaction between lens region with lens fit (p<0.001). For edge band width, there was a significant effect of time (F=118.503, p<0.001) and lens fit (F=5.1249, p=0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180s subjectively and 15 to 105s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.