3 resultados para SENSITIVE AMINE OXIDASE

em Aston University Research Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Markers of increased oxidative stress are known to be elevated following acute myocardial infarction and in the context of chronic left ventricular hypertrophy or heart failure, and their levels may correlate with the degree of contractile dysfunction or cardiac deficit. An obvious pathological mechanism that may account for this correlation is the potential deleterious effects of increased oxidative stress through the induction of cellular dysfunction, energetic deficit or cell death. However, reactive oxygen species have several much more subtle effects in the remodelling or failing heart that involve specific redox-regulated modulation of signalling pathways and gene expression. Such redox-sensitive regulation appears to play important roles in the development of several components of the phenotype of the failing heart, for example cardiomyocyte hypertrophy, interstitial fibrosis and chamber remodelling. In this article, we review the evidence supporting the involvement of reactive oxygen species and redox signalling pathways in the development of cardiac hypertrophy and heart failure, with a particular focus on the NADPH oxidase family of superoxide-generating enzymes which appear to be especially important in redox signalling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a highly sensitive, high Q-factor, label free and selective glucose sensor by using excessively tilted fiber grating (Ex-TFG) inscribed in the thin-cladding optical fiber (TCOF). Glucose oxidase (GOD) was covalently immobilized on optical fiber surface and the effectiveness of GOD immobilization was investigated by the fluorescence microscopy and highly accurate spectral interrogation method. In contrast to the long period grating (LPG) and optical fiber (OF) surface Plasmon resonance (SPR) based glucose sensors, the Ex-TFG configuration has merits of nearly independent cross sensitivity of the environmental temperature, simple fabrication method (no noble metal deposition or cladding etching) and high detection accuracy (or Q-factor). Our experimental results have shown that Ex-TFG in TCOF based sensor has a reliable and fast detection for the glucose concentration as low as 0.1~2.5mg/ml and a high sensitivity of ~1.514nm·(mg/ml)−1, which the detection accuracy is ~0.2857nm−1 at pH 5.2, and the limit of detection (LOD) is 0.013~0.02mg/ml at the pH range of 5.2~7.4 by using an optical spectrum analyzer with a resolution of 0.02nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high sensitive glucose sensor using microfiber based Mach-Zehnder interferometer (MZI) is proposed. Microfiber is firstly immobilized with glucose oxidase (GOD) and then employed as sensing probe in MZI. By tracking the shift of the interference spectrum, a high sensitivity up to 2.46nm. (mg/ml)-1 is achieved at the glucose concentration range of 0-3mg/ml.