23 resultados para Retinal nerve fiber thickness

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal microcirculatory changes are useful markers in patients suffering from hypertension and other cardiovascular disorders. Conversely, localized retinal nerve fiber layer defects (RNFLDs) are less frequently explored in association with hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study utilised a Normal group, an Ocular Hypertensive (OHT) group and a Primary Open Angle Glaucoma (POAG) group to investigate two aspects. Firstly, the within- and between-visit variability for stereometric measurements of the optic nerve head (ONH) using the Heidelberg Retina Tomograph (HRT); retinal nerve fibre layer (RNFL) thickness using the HRT and using optical coherence tomography with the Optical Coherence Tomography Scanner (OCT); the visual field using white-on-white (W-W), short-wavelength (SWAP) and Frequency Doubling perimetry (FDT); and retinal haemodynamics using the Heidelberg Retinal Flowmeter (HRF). Secondly, the association demonstrated between some of the derived variables. The within- and between-visit variability for stereometric measurements of the entire ONH and the between-visit variability for sectoral measurements were similar for Normals and OHTs but greater for POAGs. The within-visit variability of the visual field pointwise parameters for SWAP were greater than for W-W and FDT particularly with increase in eccentricity and for the OHT group. The between-visit variability increased with increase in defect depth for the POAG group, across all types of perimetry. The MS was greater, the MD and PSD smaller and the examination duration shorter in FDT compared to W-W and SWAP across all groups. The within-visit variability was less than the between-visit variability for the OCT circumferential and sector RNFL thickness using the 1.5R, 2.0R and the fixed 1.73mm circular scan radii, across the three groups. The variability increased with decrease in the RNFL thickness, and was least for the 2.0R scan radius.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis and monitoring of ocular disease presents considerable clinical difficulties for two main reasons i) the substantial physiological variation of anatomical structure of the visual pathway and ii) constraints due to technical limitations of diagnostic hardware. These are further confounded by difficulties in detecting early loss or change in visual function due to the masking of disease effects, for example, due to a high degree of redundancy in terms of nerve fibre number along the visual pathway. This thesis addresses these issues across three areas of study: 1. Factors influencing retinal thickness measures and their clinical interpretation As the retina is the principal anatomical site for damage associated with visual loss, objective measures of retinal thickness and retinal nerve fibre layer thickness are key to the detection of pathology. In this thesis the ability of optical coherence tomography (OCT) to provide repeatable and reproducible measures of retinal structure at the macula and optic nerve head is investigated. In addition, the normal physiological variations in retinal thickness and retinal nerve fibre layer thickness are explored. Principal findings were: • Macular retinal thickness and optic nerve head measurements are repeatable and reproducible for normal subjects and diseased eyes • Macular and retinal nerve fibre layer thickness around the optic nerve correlate negatively with axial length, suggesting that larger eyes have thinner retinae, potentially making them more susceptible to damage or disease • Foveola retinal thickness increases with age while retinal nerve fibre layer thickness around the optic nerve head decreases with age. Such findings should be considered during examination of the eye with suspect pathology or in long-term disease monitoring 2. Impact of glucose control on retinal anatomy and function in diabetes Diabetes is a major health concern in the UK and worldwide and diabetic retinopathy is a major cause of blindness in the working population. Objective, quantitative measurements of retinal thickness. particularly at the macula provide essential information regarding disease progression and the efficacy of treatment. Functional vision loss in diabetic patients is commonly observed in clinical and experimental studies and is thought to be affected by blood glucose levels. In the first study of its kind, the short term impact of fluctuations in blood glucose levels on retinal structure and function over a 12 hour period in patients with diabetes are investigated. Principal findings were: • Acute fluctuations in blood glucose levels are greater in diabetic patients than normal subjects • The fluctuations in blood glucose levels impact contrast sensitivity scores. SWAP visual fields, intraocular pressure and diastolic pressure. This effect is similar for type 1 and type 2 diabetic patients despite the differences in their physiological status. • Long-term metabolic control in the diabetic patient is a useful predictor in the fluctuation of contrast sensitivity scores. • Large fluctuations in blood glucose levels and/or visual function and structure may be indicative of an increased risk of development or progression of retinopathy 3. Structural and functional damage of the visual pathway in glaucomatous optic neuropathy The glaucomatous eye undergoes a number of well documented pathological changes including retinal nerve fibre loss and optic nerve head damage which is correlated with loss of functional vision. In experimental glaucoma there is evidence that glaucomatous damage extends from retinal ganglion cells in the eye, along the visual pathway, to vision centres in the brain. This thesis explores the effects of glaucoma on retinal nerve fibre layer thickness, ocular anterior anatomy and cortical structure, and its correlates with visual function in humans. Principal findings were: • In the retina, glaucomatous retinal nerve fibre layer loss is less marked with increasing distance from the optic nerve head, suggesting that RNFL examination at a greater distance than traditionally employed may provide invaluable early indicators of glaucomatous damage • Neuroretinal rim area and retrobulbar optic nerve diameter are strong indicators of visual field loss • Grey matter density decreases at a rate of 3.85% per decade. There was no clear evidence of a disease effect • Cortical activation as measured by fMRI was a strong indicator of functional damage in patients with significant neuroretinal rim loss despite relatively modest visual field defects These investigations have shown that the effects of senescence are evident in both the anterior and posterior visual pathway. A variety of anatomical and functional diagnostic protocols for the investigation of damage to the visual pathway in ocular disease are required to maximise understanding of the disease processes and thereby optimising patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether curve-fitting analysis of the ranked segment distributions of topographic optic nerve head (ONH) parameters, derived using the Heidelberg Retina Tomograph (HRT), provide a more effective statistical descriptor to differentiate the normal from the glaucomatous ONH. Methods: The sample comprised of 22 normal control subjects (mean age 66.9 years; S.D. 7.8) and 22 glaucoma patients (mean age 72.1 years; S.D. 6.9) confirmed by reproducible visual field defects on the Humphrey Field Analyser. Three 10°-images of the ONH were obtained using the HRT. The mean topography image was determined and the HRT software was used to calculate the rim volume, rim area to disc area ratio, normalised rim area to disc area ratio and retinal nerve fibre cross-sectional area for each patient at 10°-sectoral intervals. The values were ranked in descending order, and each ranked-segment curve of ordered values was fitted using the least squares method. Results: There was no difference in disc area between the groups. The group mean cup-disc area ratio was significantly lower in the normal group (0.204 ± 0.16) compared with the glaucoma group (0.533 ± 0.083) (p < 0.001). The visual field indices, mean deviation and corrected pattern S.D., were significantly greater (p < 0.001) in the glaucoma group (-9.09 dB ± 3.3 and 7.91 ± 3.4, respectively) compared with the normal group (-0.15 dB ± 0.9 and 0.95 dB ± 0.8, respectively). Univariate linear regression provided the best overall fit to the ranked segment data. The equation parameters of the regression line manually applied to the normalised rim area-disc area and the rim area-disc area ratio data, correctly classified 100% of normal subjects and glaucoma patients. In this study sample, the regression analysis of ranked segment parameters method was more effective than conventional ranked segment analysis, in which glaucoma patients were misclassified in approximately 50% of cases. Further investigation in larger samples will enable the calculation of confidence intervals for normality. These reference standards will then need to be investigated for an independent sample to fully validate the technique. Conclusions: Using a curve-fitting approach to fit ranked segment curves retains information relating to the topographic nature of neural loss. Such methodology appears to overcome some of the deficiencies of conventional ranked segment analysis, and subject to validation in larger scale studies, may potentially be of clinical utility for detecting and monitoring glaucomatous damage. © 2007 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard SAP visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. The purpose of this study is to examine the benefit of adding mfVEP hemifield Intersector analysis protocol to the standard HFA test when there is suspicious glaucomatous visual field loss. 3 groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey visual field HFA test 24-2, optical coherence tomography of the optic nerve head, and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the Hemifield Sector Analysis HSA protocol. The retinal nerve fibre (RNFL) thickness was recorded to identify subjects with suspicious RNFL loss. The hemifield Intersector analysis of mfVEP results showed that signal to noise ratio (SNR) difference between superior and inferior hemifields was statistically significant between the 3 groups (ANOVA p<0.001 with a 95% CI). The difference between superior and inferior hemispheres in all subjects were all statistically significant in the glaucoma patient group 11/11 sectors (t-test p<0.001), partially significant 5/11 in glaucoma suspect group (t-test p<0.01) and no statistical difference between most sectors in normal group (only 1/11 was significant) (t-test p<0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86% respectively, while for glaucoma suspect were 89% and 79%. The use of SAP and mfVEP results in subjects with suspicious glaucomatous visual field defects, identified by low RNFL thickness, is beneficial in confirming early visual field defects. The new HSA protocol used in the mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patient. Using this protocol in addition to SAP analysis can provide information about focal visual field differences across the horizontal midline, and confirm suspicious field defects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. The Intersector analysis protocol can detect early field changes not detected by standard HFA test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Poster Introduction: In neovascular age-related macular degeneration (nAMD), optical coherence tomography (OCT) is an important tool to determine when intravitreal injections of ranibizumab should be administered. Current guidelines recommend that patients should be reviewed four weekly and OCT indications for further treatment include subretinal fluid and intraretinal fluid or cysts. Purpose: We have reviewed the OCT scans of subjects who have successfully responded to ranibizumab to look for factors that might predict which patients will not require injection and could have extended appointments. Method: This was a prospective study in which we observed for 6 consecutive months the OCT images of 28 subjects who had received intravitreal ranibizumab for nAMD and were judged to be clinically inactive at recruitment to the study. Ratios between full retinal thickness (FRT = neurosensory retina + outer reflective band) and outer reflective band (ORB) thickness at the fovea were calculated for each subject at the moment of entering the study and at each successive visit for 6 consecutive months. Results: Patients with lower FRT/ORB ratios were found to be less likely to require an additional injection of ranibizumab and no subject with a ratio of 1.75 or less needed further injections. Conclusion: This small pilot study suggests that on macular OCT, the FRT/ORB ratio, and in particular values of 1.75 or less, may prove to be a useful, practical tool when deciding the follow up period for subjects undergoing treatment with intravitreal ranibizumab for nAMD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Poster section Design. Retrospective study. Purpose. To assess whether there are changes in foveal thickness (FT) and total macular volume (TMV) in pregnancy in diabetic subjects. Methods. The audit consisted of pregnant women with diabetes, with no maculopathy, who completed their antenatal care at Birmingham Heartlands Hospital. The Zeiss Stratus Optical coherence tomography (OCT) was performed on patients attending diabetic retinopathy (DR) screening at intervals throughout their pregnancy. To be included in the audit patients had to have at least one OCT scan during their pregnancy. Results. Altogether there were 8 type 1 and 22 type 2 patients with mean diabetes duration of 6 years (range 1-20). Mean gestation at DR screening with OCT during the first trimester was 9.7 weeks (6-13) (n=22). The mean and standard deviation for FT for the right was 179.1 µm ± 21.49 and for the left eye was 187.3 µm ± 23.55. The mean TMV was right 6.43 µm ± 0.35 and left 6.50 µm ± 0.39. The mean gestation at DR screening with OCT during the second trimester was 23.4 weeks (18-26) (n=25). The mean FT for the right was 191.4 µm ± 22.70 and the left 195.6 µm ± 24.77. The mean TMV was right 6.74 µm ± 0.45 and left 6.91 µm ± 0.35. The gestation of DR screening with OCT during the third trimester was 31.1 weeks (27-36) (n=15). The mean FT for the right was 181.5 µm ± 24.84 and for the left 193.1 µm ± 28.55. The mean TMV was right 6.80 µm ± 0.40 and left 6.84 µm ± 0.31. There were no significant differences in FT over the 3 trimesters. The TMV showed a significant difference when comparing the first and second trimesters (p<0.05). However, there was no significant statistical difference in TMV in the second and third trimesters. None of the patients showed any macula edema on the OCT. Conclusions. The results suggest there is no significant change in foveal thickness in pregnancy in diabetic subjects. There was a significant statistical difference in total macular volume in the second trimester; however, this would not be clinically significant. This is an important observation proven by the OCT which has not been previously studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Early detection of glaucoma relies on a detailed knowledge of how the normal optic nerve (ONH) varies within the population. The purpose of this study focused on two main areas; 1. To explore the optic nerve head appearance in the normal optometric population and compare the south Asian (principally Pakistani) with the European white population, correcting for possible ocular and non-ocular influences in a multiple regression model. The main findings were: • The optic discs of the South Asian (SA) and White European (WE) populations were not statistically different in size. The SA group possessed discs with increased cupping and thinner neuro-retinal rims (NRR) compared with the WE group. The SA group also demonstrated a more vertically oval shape than the WE population. These differences were significant at the p<0.01 level. • The upper limits of inter-eye asymmetry were: ≤0.2 for cup to disc area ratio, and 3mmHg for intra-ocular pressure (IOP) for both ethnic groups and this did not increase with age. IOP asymmetry did not vary with gender, ethnicity or a family history of glaucoma and was independent of ONH asymmetry. ONH and IOP asymmetry are therefore independent risk factors when screening for glaucoma for both ethnic groups. 2. To investigate the validity of the ISNT rule: inferior> superior> nasal> temporal NRR thickness in the optometric population. The main findings were: • As disc size increased the disc become rounder and less vertically oval in shape. Vertically oval discs had thicker superior and inferior NRRs and thinner nasal and temporal NRRs compared with rounder disc shapes due to cup shape being independent of disc shape. Vertically oval discs were therefore more likely to obey the ISNT rule than larger rounder discs. • The ISNT rule has a low adherence in our sample of normal eyes (5.7%). However, by removing the nasal sector to become the IST rule, 74.5% of normal eyes obeyed. SA eyes and female gender were more likely to obey the ISNT rule due to increased disc ovality. The IST rule is independent of disc shape and therefore more suitable for assessing discs from both ethnic backgrounds. Obeying the ISNT rule or IST rule was not related to disc or cup size.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To investigate whether eyes with diabetic macular edema (DME) and central retinal thickness (CRT) >400 μm had better visual and anatomical outcomes compared to eyes with a CRT <400 μm when treated with intravitreal bevacizumab in a real-world setting. Patients and methods: Patients undergoing intravitreal bevacizumab therapy for DME were identified from the departmental database of a tertiary referral unit. Following the initial injection, a retreatment was performed for any persistent macular edema, unless there had been no previous response to repeated doses. Recorded parameters included visual acuity, CRT on optical coherence tomography (spectral domain optical coherence tomography [SD-OCT]), and SD-OCT characteristics. Comparisons were made between data at baseline and 12 months after the first injection, and differences were tested for statistical significance using the Student's t-test. Results: In all, 175 eyes of 142 patients were analyzed. Patients in group 2 (CRT >400 μm) had significantly more injections than group 1 (CRT <400 μm) (4.0 versus 3.3; P=0.003). Both groups had similar numbers of eyes with preexisting epiretinal membrane and/or vitreomacular traction at baseline. The reduction in CRT was significantly greater in group 2 when compared to group 1 (P<0.0001). In terms of visual gain between baseline and month 12, each gained significantly by a mean of 0.12 logarithm of the minimum angle of resolution units (P=0.0001), but there was no difference between groups 1 and 2 (P=0.99). Conclusion: These results do not support a 400 μm baseline CRT cut-off for treating DME with bevacizumab, in contrast to published data on ranibizumab. Our results also indicate that patients with a thicker CRT require more bevacizumab injections, making treatment less cost-effective for these patients. Our results could be used by practitioners to support the use of bevacizumab in DME without applying a CRT cut-off. © 2014 Mushtaq et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To evaluate the repeatability and reproducibility of subfoveal choroidal thickness (CT) calculations performed manually using optical coherence tomography (OCT). Methods. The CT was imaged in vivo at each of two visits on 11 healthy volunteers (mean age, 35.72 ± 13.19 years) using the spectral domain OCT. CT was manually measured after applying ImageJ processing filters on 15 radial subfoveal scans. Each radial scan was spaced 12° from each other and contained 2500 A-scans. The coefficient of variability, coefficient of repeatability (CoR), coefficient of reproducibility, and intraclass correlation coefficient determined the reproducibility and repeatability of the calculation. Axial length (AL) and mean spherical equivalent refractive error were measured with the IOLMaster and an open view autorefractor to study their potential relationship with CT. Results. The within-visit and between-visit coefficient of variability, CoR, coefficient of reproducibility, and intraclass correlation coefficient were 0.80, 2.97% 2.44%, and 99%, respectively. The subfoveal CT correlated significantly with AL (R = -0.60, p = 0.05). Conclusions. The subfoveal CT could be measured manually in vivo using OCT and the readings obtained from the healthy subjects evaluated were repeatable and reproducible. It is proposed that OCT could be a useful instrument to perform in vivo assessment and monitoring of CT changes in retinal disease. The preliminary results suggest a negative correlation between subfoveal CT and AL in such a way that it decreases with increasing AL but not with refractive error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corpora amylacea (CA) are spherical or ovoid bodies 50-50 microns in diameter. They have been described in normal elderly brain as well as in a number of neurodegenerative disorders. In this study, the incidence of CA in the optic nerves of Alzheimer's disease (AD) patients was compared with normal elderly controls. Samples of optic nerves (MRC Brain Bank, Institute of Psychiatry) were taken from 12 AD patients (age range 69-94 years) and 18 controls (43-82 years). Optic nerves were fixed in 2% buffered glutaraldehyde, post-fixed in osmium tetroxide, embedded in epoxy resin and then sectioned to a thickness of 2 microns. Sections were stained with toluidine blue. CA were present in all of the optic nerves examined. In addition, a number of similarly stained but more irregularly shaped bodies were present. Fewer CA were found in the optic nerves of AD patients compared with controls. By contrast, the number or irregularly shaped bodies was increased in AD. In AD, there may be a preferential decline in the large diameter fibres which may mediate the M-cell pathway. Hence, the decline in the incidence of CA in AD may be associated with a reduction in these fibres. It is also possible that the irregualrly shaped bodies are a degeneration product of the CA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate the relationship between vascular function parameters measured at the retinal and systemic level and known markers for cardiovascular risk in patients with impaired glucose tolerance (IGT). Sixty age- and gender- matched White-European adults (30 IGT and 30 normal glucose tolerance -NGT) were recruited for the study. Fasting plasma glucose, lipids and 24-hour blood pressure (BP) was measured in all subjects. Systemic vascular and endothelial function was assessed using carotid-artery intimal media thickness (cIMT) and flow mediated dilation (FMD). Retinal vascular reactivity was assessed by the Dynamic Retinal Vessel Analyser (DVA). Additionally, blood glutathione (GSH, GSSG and tGSH) and plasma von-Willebrand (vWF) factor levels were also measured. Individuals with IGT demonstrated higher BP values (p<0.001), fasting TG and TG:HDL ratios (p<0.001) than NGT subjects. Furthermore, Total:HDL-C ratios and Framingham scores were raised (p=0.010 and p<0.001 respectively). Blood glutathione levels (GSH, GSSG and tGSH) were lower (p<0.001, p=0.039 and p<0.001 respectively) while plasma vWF was increased (p=0.014) in IGT subjects compared to controls. IGT individuals also demonstrated higher IMT in right and left carotid arteries (p=0.017 and p=0.005, respectively) alongside larger brachial artery diameter (p=0.015), lower FMD% (p=0.026) and GTN induced dilation (GID) (p=0.012) than healthy controls. At the retinal arterial level, the IGT subjects showed higher baseline fluctuations (BDF) (p=0.026), longer reaction time (RT) (p=0.032) and reduced baseline-corrected flicker response (bFR) (p=0.045). In IGT subjects retinal BDF correlated with and Total:HDL (p= 0.003) and HDL-C (p= 0.004). Arterial RT also correlated with FMD (p=0.017) in IGT but not NGT subjects. In IGT individuals there is a relationship between macro- and microvascular function, as well as a direct correlation between the observed retinal microcirculatory changes and established plasma markers for CVD. Multifactorial preventive interventions to decrease vascular risk in these individuals should be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presentation Purpose:We conducted a study to determine if the spectral domain optical coherence tomography (SD-OCT) could be used as a tool to assess effective delivery of threshold and subthreshold laser burns created using 532nm green wavelength laser. Methods:10 patients planned for panretinal photocoagulation (PRP) for proliferative diabetic retinopathy were included in this study. Before initiating the full PRP, a row of moderately white laser burns as used for conventional PRP was created using 532 nm laser set at threshold power for 0.1 second with 300 microns spot size. Further rows of laser burns were created by altering the duration and power settings on the laser device. The area of the retina irradiated with laser was imaged using the Topcon SD-OCT within a few minutes of laser treatment. Results:Laser burns created using threshold power were seen on the OCT scan in all cases as a homogenous diffuse increase in reflectivity extending across the full thickness of retina (Fig 1). Retinal burns created by lowering the duration of laser pulse to 0.01s were barely visible ophthalmoscopically but were clearly detectable on the OCT scan as a localised, well-defined area of increased tissue reflectivity (Fig 2). Conclusions:OCT is a useful to tool to assess the delivery of laser burns created using the 532 nm green laser. Burns of a subthreshold intensity that may not be visible ophthalmoscopically result in retinal changes that are clearly detectable on OCT imaging. Further studies would be needed to assess the clinical effectiveness of subthreshold laser treatment for retinal vascular diseases using the 532 nm green laser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces a revolutionary way to interrogate optical fiber sensors based on fiber Bragg gratings (FBGs) and to integrate the necessary driving optoelectronic components with the sensor elements. Low-cost optoelectronic chips are used to interrogate the optical fibers, creating a portable dynamic sensing system as an alternative for the traditionally bulky and expensive fiber sensor interrogation units. The possibility to embed these laser and detector chips is demonstrated resulting in an ultra thin flexible optoelectronic package of only 40 µm, provided with an integrated planar fiber pigtail. The result is a fully embedded flexible sensing system with a thickness of only 1 mm, based on a single Vertical-Cavity Surface-Emitting Laser (VCSEL), fiber sensor and photodetector chip. Temperature, strain and electrodynamic shaking tests have been performed on our system, not limited to static read-out measurements but dynamically reconstructing full spectral information datasets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fiber Bragg gratings can be used for monitoring different parameters in a wide variety of materials and constructions. The interrogation of fiber Bragg gratings traditionally consists of an expensive and spacious peak tracking or spectrum analyzing unit which needs to be deployed outside the monitored structure. We present a dynamic low-cost interrogation system for fiber Bragg gratings which can be integrated with the fiber itself, limiting the fragile optical in- and outcoupling interfaces and providing a compact, unobtrusive driving and read-out unit. The reported system is based on an embedded Vertical Cavity Surface Emitting Laser (VCSEL) which is tuned dynamically at 1 kHz and an embedded photodiode. Fiber coupling is provided through a dedicated 45° micromirror yielding a 90° in-the-plane coupling and limiting the total thickness of the fiber coupled optoelectronic package to 550 µm. The red-shift of the VCSEL wavelength is providing a full reconstruction of the spectrum with a range of 2.5 nm. A few-mode fiber with fiber Bragg gratings at 850 nm is used to prove the feasibility of this low-cost and ultra-compact interrogation approach.