15 resultados para Retinal nerve fiber layer

em Aston University Research Archive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retinal microcirculatory changes are useful markers in patients suffering from hypertension and other cardiovascular disorders. Conversely, localized retinal nerve fiber layer defects (RNFLDs) are less frequently explored in association with hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study utilised a Normal group, an Ocular Hypertensive (OHT) group and a Primary Open Angle Glaucoma (POAG) group to investigate two aspects. Firstly, the within- and between-visit variability for stereometric measurements of the optic nerve head (ONH) using the Heidelberg Retina Tomograph (HRT); retinal nerve fibre layer (RNFL) thickness using the HRT and using optical coherence tomography with the Optical Coherence Tomography Scanner (OCT); the visual field using white-on-white (W-W), short-wavelength (SWAP) and Frequency Doubling perimetry (FDT); and retinal haemodynamics using the Heidelberg Retinal Flowmeter (HRF). Secondly, the association demonstrated between some of the derived variables. The within- and between-visit variability for stereometric measurements of the entire ONH and the between-visit variability for sectoral measurements were similar for Normals and OHTs but greater for POAGs. The within-visit variability of the visual field pointwise parameters for SWAP were greater than for W-W and FDT particularly with increase in eccentricity and for the OHT group. The between-visit variability increased with increase in defect depth for the POAG group, across all types of perimetry. The MS was greater, the MD and PSD smaller and the examination duration shorter in FDT compared to W-W and SWAP across all groups. The within-visit variability was less than the between-visit variability for the OCT circumferential and sector RNFL thickness using the 1.5R, 2.0R and the fixed 1.73mm circular scan radii, across the three groups. The variability increased with decrease in the RNFL thickness, and was least for the 2.0R scan radius.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis and monitoring of ocular disease presents considerable clinical difficulties for two main reasons i) the substantial physiological variation of anatomical structure of the visual pathway and ii) constraints due to technical limitations of diagnostic hardware. These are further confounded by difficulties in detecting early loss or change in visual function due to the masking of disease effects, for example, due to a high degree of redundancy in terms of nerve fibre number along the visual pathway. This thesis addresses these issues across three areas of study: 1. Factors influencing retinal thickness measures and their clinical interpretation As the retina is the principal anatomical site for damage associated with visual loss, objective measures of retinal thickness and retinal nerve fibre layer thickness are key to the detection of pathology. In this thesis the ability of optical coherence tomography (OCT) to provide repeatable and reproducible measures of retinal structure at the macula and optic nerve head is investigated. In addition, the normal physiological variations in retinal thickness and retinal nerve fibre layer thickness are explored. Principal findings were: • Macular retinal thickness and optic nerve head measurements are repeatable and reproducible for normal subjects and diseased eyes • Macular and retinal nerve fibre layer thickness around the optic nerve correlate negatively with axial length, suggesting that larger eyes have thinner retinae, potentially making them more susceptible to damage or disease • Foveola retinal thickness increases with age while retinal nerve fibre layer thickness around the optic nerve head decreases with age. Such findings should be considered during examination of the eye with suspect pathology or in long-term disease monitoring 2. Impact of glucose control on retinal anatomy and function in diabetes Diabetes is a major health concern in the UK and worldwide and diabetic retinopathy is a major cause of blindness in the working population. Objective, quantitative measurements of retinal thickness. particularly at the macula provide essential information regarding disease progression and the efficacy of treatment. Functional vision loss in diabetic patients is commonly observed in clinical and experimental studies and is thought to be affected by blood glucose levels. In the first study of its kind, the short term impact of fluctuations in blood glucose levels on retinal structure and function over a 12 hour period in patients with diabetes are investigated. Principal findings were: • Acute fluctuations in blood glucose levels are greater in diabetic patients than normal subjects • The fluctuations in blood glucose levels impact contrast sensitivity scores. SWAP visual fields, intraocular pressure and diastolic pressure. This effect is similar for type 1 and type 2 diabetic patients despite the differences in their physiological status. • Long-term metabolic control in the diabetic patient is a useful predictor in the fluctuation of contrast sensitivity scores. • Large fluctuations in blood glucose levels and/or visual function and structure may be indicative of an increased risk of development or progression of retinopathy 3. Structural and functional damage of the visual pathway in glaucomatous optic neuropathy The glaucomatous eye undergoes a number of well documented pathological changes including retinal nerve fibre loss and optic nerve head damage which is correlated with loss of functional vision. In experimental glaucoma there is evidence that glaucomatous damage extends from retinal ganglion cells in the eye, along the visual pathway, to vision centres in the brain. This thesis explores the effects of glaucoma on retinal nerve fibre layer thickness, ocular anterior anatomy and cortical structure, and its correlates with visual function in humans. Principal findings were: • In the retina, glaucomatous retinal nerve fibre layer loss is less marked with increasing distance from the optic nerve head, suggesting that RNFL examination at a greater distance than traditionally employed may provide invaluable early indicators of glaucomatous damage • Neuroretinal rim area and retrobulbar optic nerve diameter are strong indicators of visual field loss • Grey matter density decreases at a rate of 3.85% per decade. There was no clear evidence of a disease effect • Cortical activation as measured by fMRI was a strong indicator of functional damage in patients with significant neuroretinal rim loss despite relatively modest visual field defects These investigations have shown that the effects of senescence are evident in both the anterior and posterior visual pathway. A variety of anatomical and functional diagnostic protocols for the investigation of damage to the visual pathway in ocular disease are required to maximise understanding of the disease processes and thereby optimising patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine whether curve-fitting analysis of the ranked segment distributions of topographic optic nerve head (ONH) parameters, derived using the Heidelberg Retina Tomograph (HRT), provide a more effective statistical descriptor to differentiate the normal from the glaucomatous ONH. Methods: The sample comprised of 22 normal control subjects (mean age 66.9 years; S.D. 7.8) and 22 glaucoma patients (mean age 72.1 years; S.D. 6.9) confirmed by reproducible visual field defects on the Humphrey Field Analyser. Three 10°-images of the ONH were obtained using the HRT. The mean topography image was determined and the HRT software was used to calculate the rim volume, rim area to disc area ratio, normalised rim area to disc area ratio and retinal nerve fibre cross-sectional area for each patient at 10°-sectoral intervals. The values were ranked in descending order, and each ranked-segment curve of ordered values was fitted using the least squares method. Results: There was no difference in disc area between the groups. The group mean cup-disc area ratio was significantly lower in the normal group (0.204 ± 0.16) compared with the glaucoma group (0.533 ± 0.083) (p < 0.001). The visual field indices, mean deviation and corrected pattern S.D., were significantly greater (p < 0.001) in the glaucoma group (-9.09 dB ± 3.3 and 7.91 ± 3.4, respectively) compared with the normal group (-0.15 dB ± 0.9 and 0.95 dB ± 0.8, respectively). Univariate linear regression provided the best overall fit to the ranked segment data. The equation parameters of the regression line manually applied to the normalised rim area-disc area and the rim area-disc area ratio data, correctly classified 100% of normal subjects and glaucoma patients. In this study sample, the regression analysis of ranked segment parameters method was more effective than conventional ranked segment analysis, in which glaucoma patients were misclassified in approximately 50% of cases. Further investigation in larger samples will enable the calculation of confidence intervals for normality. These reference standards will then need to be investigated for an independent sample to fully validate the technique. Conclusions: Using a curve-fitting approach to fit ranked segment curves retains information relating to the topographic nature of neural loss. Such methodology appears to overcome some of the deficiencies of conventional ranked segment analysis, and subject to validation in larger scale studies, may potentially be of clinical utility for detecting and monitoring glaucomatous damage. © 2007 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard SAP visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. The purpose of this study is to examine the benefit of adding mfVEP hemifield Intersector analysis protocol to the standard HFA test when there is suspicious glaucomatous visual field loss. 3 groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey visual field HFA test 24-2, optical coherence tomography of the optic nerve head, and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the Hemifield Sector Analysis HSA protocol. The retinal nerve fibre (RNFL) thickness was recorded to identify subjects with suspicious RNFL loss. The hemifield Intersector analysis of mfVEP results showed that signal to noise ratio (SNR) difference between superior and inferior hemifields was statistically significant between the 3 groups (ANOVA p<0.001 with a 95% CI). The difference between superior and inferior hemispheres in all subjects were all statistically significant in the glaucoma patient group 11/11 sectors (t-test p<0.001), partially significant 5/11 in glaucoma suspect group (t-test p<0.01) and no statistical difference between most sectors in normal group (only 1/11 was significant) (t-test p<0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86% respectively, while for glaucoma suspect were 89% and 79%. The use of SAP and mfVEP results in subjects with suspicious glaucomatous visual field defects, identified by low RNFL thickness, is beneficial in confirming early visual field defects. The new HSA protocol used in the mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patient. Using this protocol in addition to SAP analysis can provide information about focal visual field differences across the horizontal midline, and confirm suspicious field defects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. The Intersector analysis protocol can detect early field changes not detected by standard HFA test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Novel surface plasmonic optical fiber sensors have been fabricated using multiple coatings deposited on a lapped section of a single mode fiber. UV laser irradiation processing with a phase mask produces a nano-scaled surface relief grating structure resembling nano-wires. The resulting individual corrugations produced by material compaction are approximately 20 μm long with an average width at half maximum of 100 nm and generate localized surface plasmons. Experimental data are presented that show changes in the spectral characteristics after UV processing, coupled with an overall increase in the sensitivity of the devices to surrounding refractive index. Evidence is presented that there is an optimum UV dosage (48 joules) over which no significant additional optical change is observed. The devices are characterized with regards to change in refractive index, where significantly high spectral sensitivities in the aqueous index regime are found, ranging up to 4000 nm/RIU for wavelength and 800 dB/RIU for intensity. © 2013 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We studied the effects of the composition of impregnating solution and heat treatment conditions on the activity of catalytic systems for the low-temperature oxidation of CO obtained by the impregnation of Busofit carbon-fiber cloth with aqueous solutions of palladium, copper, and iron salts. The formation of an active phase in the synthesized catalysts at different stages of their preparation was examined with the use of differential thermal and thermogravimetric analyses, X-ray diffraction analysis, X-ray photoelectron spectroscopy, and elemental spectral analysis. The catalytic system prepared by the impregnation of electrochemically treated Busofit with the solutions of PdCl, FeCl, CuBr, and Cu(NO ) and activated under optimum conditions ensured 100% CO conversion under a respiratory regime at both low (0.03%) and high (0.5%) carbon monoxide contents of air. It was found that the activation of a catalytic system at elevated temperatures (170-180°C) leads to the conversion of Pd(II) into Pd(I), which was predominantly localized in a near-surface layer. The promoting action of copper nitrate consists in the formation of a crystalline phase of the rhombic atacamite CuCl(OH). The catalyst surface is finally formed under the conditions of a catalytic reaction, when a joint Pd(I)-Cu(I) active site is formed. © 2014 Pleiades Publishing, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Early detection of glaucoma relies on a detailed knowledge of how the normal optic nerve (ONH) varies within the population. The purpose of this study focused on two main areas; 1. To explore the optic nerve head appearance in the normal optometric population and compare the south Asian (principally Pakistani) with the European white population, correcting for possible ocular and non-ocular influences in a multiple regression model. The main findings were: • The optic discs of the South Asian (SA) and White European (WE) populations were not statistically different in size. The SA group possessed discs with increased cupping and thinner neuro-retinal rims (NRR) compared with the WE group. The SA group also demonstrated a more vertically oval shape than the WE population. These differences were significant at the p<0.01 level. • The upper limits of inter-eye asymmetry were: ≤0.2 for cup to disc area ratio, and 3mmHg for intra-ocular pressure (IOP) for both ethnic groups and this did not increase with age. IOP asymmetry did not vary with gender, ethnicity or a family history of glaucoma and was independent of ONH asymmetry. ONH and IOP asymmetry are therefore independent risk factors when screening for glaucoma for both ethnic groups. 2. To investigate the validity of the ISNT rule: inferior> superior> nasal> temporal NRR thickness in the optometric population. The main findings were: • As disc size increased the disc become rounder and less vertically oval in shape. Vertically oval discs had thicker superior and inferior NRRs and thinner nasal and temporal NRRs compared with rounder disc shapes due to cup shape being independent of disc shape. Vertically oval discs were therefore more likely to obey the ISNT rule than larger rounder discs. • The ISNT rule has a low adherence in our sample of normal eyes (5.7%). However, by removing the nasal sector to become the IST rule, 74.5% of normal eyes obeyed. SA eyes and female gender were more likely to obey the ISNT rule due to increased disc ovality. The IST rule is independent of disc shape and therefore more suitable for assessing discs from both ethnic backgrounds. Obeying the ISNT rule or IST rule was not related to disc or cup size.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New heterogenized catalytic systems for the low-temperature oxidation of CO were synthesized by supporting solutions of Pd, Cu, and Fe salts on carbon fibrous materials (carbopon and busofit). The carbon supports were studied by elemental analysis, SEM, TGA, and TPD. The effects of the nature of the support, the concentration and composition of the active component, and the conditions of preparation on the efficiency of the catalytic system were studied. It was ascertained that attenuation of hydrophilic properties of the support led to the decrease in system activity. The investigation of the catalysts by XPS showed that sample treatment in the reaction medium results in redistribution of the components of the active phase in the near-surface layer of the catalyst. The catalytic system based on carbon fibrous material carbopon prepared by supporting active components (Pd, Cu, and Fe salts) in three stages with intermediate activation in the reaction medium ensures 95% conversion of CO under respiratory conditions, and is promising for the design of the main element of breathing masks on its basis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present what is to our knowledge the first demonstration of a tunable fiber Bragg grating device in polymer optical fiber that utilizes a thin-film resistive heater deposited on the surface of the fiber. The polymer fiber was coated via photochemical deposition of a Pd/Cu metallic layer with a procedure induced by vacuum-ultraviolet radiation at room temperature. The resulting device, when wavelength tuned via joule heating, underwent a wavelength shift of 2 nm for a moderate input power of 160 mW, a wavelength to input power coefficient of-13.4 pm/mW, and a time constant of 1.7 s-1. © 2007 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we consider the possibility of using intermediate solutions, in which ideal apodisation profile for a dispersion-free, sharp-reflection profile fibre Bragg grating approximated in different degrees. The ideal apodisation profile for a flat dispersion, 50 GHz bandwidth grating was obtained using the layer-peeling algorithm. To verify the modelled results a version of the 5-section grating has been manufactured with excellent agreement between the model and the experimental results. The performance penalty due to multiple reflections from the FBGs in different situations was studied. The results showed that in the approximated gratings some post-compensation must be included to account for the local deviations from zero dispersion. © 2003 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate whether regional long-term changes in peripapillary retinal flow, measured by scanning laser Doppler flowmetry (SLDF), occur in patients with primary open angle glaucoma (POAG). Methods: 31 healthy volunteers (mean age: 65 8.3 years) and 33 POAG patients (mean age: 71.2 7.6 years) were followed up every 4 months for 16 months. Using SLDF, three images of the superior and inferior optic nerve head were obtained for each subject. A 1010-pixel frame was used to measure blood flow, volume and velocity in the four quadrants of the peripapillary retina. Central 24-2 visual field testing was carried out at each visit. Repeated measures analysis of covariance was used to assess change over time between the normal and POAG groups for the SLDF parameters. Univariate linear regression analysis for mean deviation and glaucoma change probability (GCP) analysis were used to identify visual field progression. Results: Blood volume, flow and velocity measured in the inferior nasal quadrant of the peripapillary retina decreased significantly over time for the POAG group compared to the normal group (p=0.0073, 0.0097, 0.0095 respectively). Overall, 2 glaucoma patients showed a significantly deteriorating MD slope, while 7 patients showed visual field progression with GPA. All of the patients progressing with GPA, showed change in the superior hemifield and, of those, 14% showed change in the inferior hemifield. Conclusion: Glaucoma patients showed a decrease in blood flow, volume and velocity in the inferior nasal peripapillary retina. A regional variation in microvascular retinal capillary blood flow may provide insight into the pathogenesis of glaucomatous optic neuropathy. Keywords: 331 blood supply • 554 retina • 624 visual fields

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeiss FF450+ fundus camera. Arterio-venous ratios (AVR), central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) were calculated on three separate occasions by one single observer semi-automatically using the software VesselMap (ImedosSystems, Jena, Germany). Following the automated grading, three examiners graded the AVR visually on three separate occasions in order to assess their agreement. Results: Reproducibility of the semi-automatic parameters was excellent (ICCs: 0.97 (CRAE); 0.985 (CRVE) and 0.952 (AVR)). However, visual grading of AVR showed inter grader differences as well as discrepancies between subjectively derived and objectively calculated AVR (all p < 0.000001). Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres. © 2014 Spanish General Council of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the Parr-Hubbard and Knudtson formulas to calculate retinal vessel calibers and to examine the effect of omitting vessels on the overall result. METHODS: We calculated the central retinal arterial equivalent (CRAE) and central retinal venular equivalent (CRVE) according to the formulas described by Parr-Hubbard and Knudtson including the six largest retinal arterioles and venules crossing through a concentric ring segment (measurement zone) around the optic nerve head. Once calculated, we removed one arbitrarily selected artery and one arbitrarily selected vein and recalculated all outcome parameters again for (1) omitting one artery only, (2) omitting one vein only, and (3) omitting one artery and one vein. All parameters were compared against each other. RESULTS: Both methods showed good correlation (r for CRAE = 0.58; r for CRVE = 0.84), but absolute values for CRAE and CRVE were significantly different from each other when comparing both methods (p < 0.000001): CRAE had higher values for the Parr-Hubbard (165 [±16] μm) method compared with the Knudtson method (148 [±15] μm). In addition, CRAE and CRVE values dropped for both methods when omitting one arbitrarily selected vessel each (all p < 0.000001). Arteriovenous ratio (AVR) calculations showed a similar change for both methods when omitting one vessel each: AVR decreased when omitting one arteriole whereas it increased when omitting one venule. No change, however, was observed for AVR calculated with six or five vessel pairs each. CONCLUSIONS: Although the absolute value for CRAE and CRVE is changing significantly depending on the number of vessels included, AVR appears to be comparable as long as the same number of arterioles and venules is included.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using excessively tilted fiber grating (Ex-TFG) inscribed in standard single mode fiber, we developed a novel label-free immunoassay for specific detection of porcine circovirus type 2 (PCV2), which is a minim animal virus. Staphylococcal protein A (SPA) was used to modify the silanized fiber surface thus forming a SPA layer, which would greatly enhance the proportion of anti-PCV2 monoclonal antibody (MAb) bioactivity, thus improving the effectiveness of specific adsorption and binding events between anti-PCV2 MAbs and PCV2 antigens. Immunoassay experiments were carried out by monitoring the resonance wavelength shift of the proposed sensor under different PCV2 titer levels. Anti-PCV2 MAbs were thoroughly dissociated from the SPA layer by treatment with urea, and recombined to the SPA layer on the sensor surface for repeated immunoassay of PCV2. The specificity of the immunosensor was inspected by detecting porcine reproductive and respiratory syndrome virus (PRRSV) first, and PCV2 subsequently. The results showed a limit of detection (LOD) for the PCV2 immunosensor of ~9.371TCID50/mL, for a saturation value of ~4.801×103TCID50/mL, with good repeatability and excellent specificity.