9 resultados para Reliability of Path
em Aston University Research Archive
Resumo:
Background/aims Macular pigment is thought to protect the macula against exposure to light and oxidative stress, both of which may play a role in the development of age-related macular degeneration. The aim was to clinically evaluate a novel cathode-ray-tube-based method for measurement of macular pigment optical density (MPOD) known as apparent motion photometry (AMP). Methods The authors took repeat readings of MPOD centrally (0°) and at 3° eccentricity for 76 healthy subjects (mean (±SD) 26.5±13.2 years, range 18–74 years). Results The overall mean MPOD for the cohort was 0.50±0.24 at 0°, and 0.28±0.20 at 3° eccentricity; these values were significantly different (t=-8.905, p<0.001). The coefficients of repeatability were 0.60 and 0.48 for the 0 and 3° measurements respectively. Conclusions The data suggest that when the same operator is taking repeated 0° AMP MPOD readings over time, only changes of more than 0.60 units can be classed as clinically significant. In other words, AMP is not suitable for monitoring changes in MPOD over time, as increases of this magnitude would not be expected, even in response to dietary modification or nutritional supplementation.
Resumo:
Security and reliability of LDPC based public-key cryptosystems are discussed and analysed. We study attacks on the cryptosystem when partial knowledge of one or more of the private key components and/or of the plaintext have been acquired.
Resumo:
Aims: To establish the sensitivity and reliability of objective image analysis in direct comparison with subjective grading of bulbar hyperaemia. Methods: Images of the same eyes were captured with a range of bulbar hyperaemia caused by vasodilation. The progression was recorded and 45 images extracted. The images were objectively analysed on 14 occasions using previously validated edge-detection and colour-extraction techniques. They were also graded by 14 eye-care practitioners (ECPs) and 14 non-clinicians (NCb) using the Efron scale. Six ECPs repeated the grading on three separate occasions Results: Subjective grading was only able to differentiate images with differences in grade of 0.70-1.03 Efron units (sensitivity of 0.30-0.53), compared to 0,02-0.09 Efron units with objective techniques (sensitivity of 0.94-0.99). Significant differences were found between ECPs and individual repeats were also inconsistent (p<0.001). Objective analysis was 16x more reliable than subjective analysis. The NCLs used wider ranges of the scale but were more variable than ECPs, implying that training may have an effect on grading. Conclusions: Objective analysis may offer a new gold standard in anterior ocular examination, and should be developed further as a clinical research tool to allow more highly powered analysis, and to enhance the clinical monitoring of anterior eye disease.
Resumo:
Descriptions of vegetation communities are often based on vague semantic terms describing species presence and dominance. For this reason, some researchers advocate the use of fuzzy sets in the statistical classification of plant species data into communities. In this study, spatially referenced vegetation abundance values collected from Greek phrygana were analysed by ordination (DECORANA), and classified on the resulting axes using fuzzy c-means to yield a point data-set representing local memberships in characteristic plant communities. The fuzzy clusters matched vegetation communities noted in the field, which tended to grade into one another, rather than occupying discrete patches. The fuzzy set representation of the community exploited the strengths of detrended correspondence analysis while retaining richer information than a TWINSPAN classification of the same data. Thus, in the absence of phytosociological benchmarks, meaningful and manageable habitat information could be derived from complex, multivariate species data. We also analysed the influence of the reliability of different surveyors' field observations by multiple sampling at a selected sample location. We show that the impact of surveyor error was more severe in the Boolean than the fuzzy classification. © 2007 Springer.
Resumo:
In this paper we report on investigations of some of the factors that have a bearing on the reliability and repeatability of polymer fibre Bragg gratings. The main issues discussed are the fibre preform composition, the fibre drawing conditions and the thermal history of the fibre grating.
Resumo:
Background: Summarised retinal vessel diameters are linked to systemic vascular pathology. Monochromatic images provide best contrast to measure vessel calibres. However, when obtaining images with a dual wavelength oximeter the red-free image can be extracted as the green channel information only which in turn will reduce the number of photographs taken at a given time. This will reduce patient exposure to the camera flash and could provide sufficient quality images to reliably measure vessel calibres. Methods: We obtained retinal images of one eye of 45 healthy participants. Central retinal arteriolar and central retinal venular equivalents (CRAE and CRVE, respectively) were measured using semi-automated software from two monochromatic images: one taken with a red-free filter and one extracted from the green channel of a dual wavelength oximetry image. Results: Participants were aged between 21 and 62 years, all were normotensive (SBP: 115 (12) mmHg; DBP: 72 (10) mmHg) and had normal intra-ocular pressures (12 (3) mmHg). Bland-Altman analysis revealed good agreement of CRAE and CRVE as obtained from both images (mean bias CRAE = 0.88; CRVE = 2.82). Conclusions: Summarised retinal vessel calibre measurements obtained from oximetry images are in good agreement to those obtained using red-free photographs.
Resumo:
Detection of elder abuse risk is a critical issue because a lot of cases remain hidden. Screening tools can be used to detect elder abuse. However, few tools have been developed for use with caregivers. The purpose was to develop a translation and adaptation of a Spanish version of the Caregiver Abuse Screen (CASE) and to assess its validity and reliability. The CASE was then used with 211 primary caregivers. Validity and reliability were evaluated, as well as the factorial structure of the instrument. This version showed good psychometric properties. It was found to have strong internal consistency and split-half reliability as well as allowing for a good replication of the original factorial structure. Additionally, several variables related to elder abuse were linked to the CASE such as depression, burden, frequency, and reactions to problem behaviors. The version developed showed sufficient validity and reliability and could be considered as a suitable instrument to assess risks of elder abuse in a Spanish-speaking context.
Resumo:
Considerable attention has been given in the literature to identifying and describing the effective elements which positively affect the improvement of product reliability. These have been perceived by many as the 'state of the art' in the manufacturing industry. The applicability, diffusion and effectiveness of such methods and philosophies, as a means of systematically improving the reliability of a product, come in the main from case studies and single and infra-industry empirical studies. These studies have both been carried out within the wider context of quality assurance and management, and taking reliability as a discipline in its own right. However, it is somewhat of a surprise that there are no recently published findings or research studies on the adoption of these methods by the machine tool industry. This may lead one to construct several hypothesised paradigms: (a) that machine tool manufacturers compared to other industries, are slow to respond to propositions given in the literature by theorists or (b) this may indicate that a large proportion of the manufacturers make little use of the reliability improvement techniques as described in the literature, with the overall perception that they will not lead to any significant improvements? On the other hand, it is evident that hypothetical verification of the operational and engineering methods of reliability achievement and improvement adopted in the machine tool industry is less widely researched. Therefore, research into this area is needed in order to explore the 'state of the art' practice in the machine tool industry. This is in terms of the status, structure and activities of the operation of the reliability function. This paper outlines a research programme being conducted with the co-operation of a leading machine tool manufacturer, whose UK manufacturing plant produces in the main Vertical Machining Centres (VMCs) and is continuously undergoing incremental transitions in product reliability improvement.
Resumo:
It is a crucial task to evaluate the reliability of manufacturing process in product development process. Process reliability is a measurement of production ability of reconfigurable manufacturing system (RMS), which serves as an integrated performance indicator of the production process under specified technical constraints, including time, cost and quality. An integration framework of manufacturing process reliability evaluation is presented together with product development process. A mathematical model and algorithm based on universal generating function (UGF) is developed for calculating the reliability of manufacturing process with respect to task intensity and process capacity, which are both independent random variables. The rework strategies of RMS are analyzed under different task intensity based on process reliability is presented, and the optimization of rework strategies based on process reliability is discussed afterwards.