15 resultados para Recording and registration
em Aston University Research Archive
Resumo:
This thesis begins by providing a review of techniques for interpreting the thermal response at the earth's surface acquired using remote sensing technology. Historic limitations in the precision with which imagery acquired from airborne platforms can be geometrically corrected and co-registered has meant that relatively little work has been carried out examining the diurnal variation of surface temperature over wide regions. Although emerging remote sensing systems provide the potential to register temporal image data within satisfactory levels of accuracy, this technology is still not widely available and does not address the issue of historic data sets which cannot be rectified using conventional parametric approaches. In overcoming these problems, the second part of this thesis describes the development of an alternative approach for rectifying airborne line-scanned imagery. The underlying assumption that scan lines within the imagery are straight greatly reduces the number of ground control points required to describe the image geometry. Furthermore, the use of pattern matching procedures to identify geometric disparities between raw line-scanned imagery and corresponding aerial photography enables the correction procedure to be almost fully automated. By reconstructing the raw image data on a truly line-by-line basis, it is possible to register the airborne line-scanned imagery to the aerial photography with an average accuracy of better than one pixel. Providing corresponding aerial photography is available, this approach can be applied in the absence of platform altitude information allowing multi-temporal data sets to be corrected and registered.
Resumo:
We present a video-based system which interactively captures the geometry of a 3D object in the form of a point cloud, then recognizes and registers known objects in this point cloud in a matter of seconds (fig. 1). In order to achieve interactive speed, we exploit both efficient inference algorithms and parallel computation, often on a GPU. The system can be broken down into two distinct phases: geometry capture, and object inference. We now discuss these in further detail. © 2011 IEEE.
Resumo:
Ambulatory EEG recording enables patients with epilepsy and related disorders to be monitored in an unrestricted environment for prolonged periods. Attacks can therefore be recorded and EEG changes at the time can aid diagnosis. The relevant Iiterature is reviewed and a study made of' 250 clinical investigations. A study was also made of the artefacts,encountered during ambulatory recording. Three quarters of referrals were for distinguishing between epileptic and non-epileptic attacks. Over 60% of patients showed no abnormality during attacks. In comparison with the basic EEG the ambulatory EEG provided about ten times as much information. A preliminary follow-up study showed that results, of ambulatory monitoring agreed with the final diagnosis in 8 of 12 patients studied. Of 10 patients referred, for monitoring the occurrence of absence seizures, 8 showed abnormality during the baslcJ EEG .and 10 during the ambulatory EEG. Other patients. were referred: for sleep recording and to clarify the seizure type. An investigation into once daily (OD) versus twice daily administration of sodium valproate in patients with absence seizures showed that an OD regime was equally as effective as a BD regime. Circadian variations in spike and wave activity in patients on and off treatment were also examined. There was significant agreement between subjects on the time of occurrence of abnormality during sleep only, This pattern was not ,affected with treatment nor was there any difference in the daily pattern of occurrence of abnormality between the two regimes. Overall findings suggested that ambulatory monitoring was a valuable tool in the diagnosis and treatment of epilepsy which with careful planning and patient selection could be used in any EEG department and would benefit a:wide range of patients.
Resumo:
As property lawyers, we are all familiar with the general principle that a contract for the sale of land, which is capable of specific performance, operates in equity so as to confer a trust on the purchaser pending completion of the sale. Although some controversy exists as to the exact nature of the trust, it is well established that, upon exchange of contracts, equity will ‘‘treat that as done which ought to be done’’1 with the consequence that the purchaser acquires equitable ownership even though full (legal) title to the land will not pass until completion (and registration). As land is unique, specific performance is readily available in the context of sales of land where damages would, clearly, not be an adequate remedy. The same cannot be said for contracts for the purchase of personal property where invariably the subject matter is not unique and where a substitute can easily be acquired in the open market. In circumstances, however, where the property is unique or scarce (for example, a rare painting or vintage car), the maxim that ‘‘equity treats as done that which ought to be done’’ may be invoked so as to confer on the seller an equitable obligation to transfer the property to the purchaser in fulfilment of the contract. Where, therefore, the contract is specifically enforceable in this way, the seller, it is submitted, will again hold the property on trust for the purchaser where, as in a contract for the sale of land, there is an interval between the date of the contract and completion of the sale. The notion that a seller holds personal property upon trust for the purchaser pending completion of the sale is admittedly controversial, but this article seeks to argue that the same principles governing equity’s intervention in sales of land should apply in the context of sales of personalty. It is submitted that equity’s role in imposing a trust on the vendor both in relation to sales of land and personalty may be important in safeguarding the interests of the purchaser prior to, as well as after, completion of the transaction.
Resumo:
Influences on general practitioner prescribing of drugs continue to be of interest and importance as cost containment becomes central to Government health policy. This thesis employs a plurality of research methods including quantitative and qualitative survey techniques for example, questionnaires, interviews and prescription analyses to investigate some of the factors which may influence GP prescribing such as information sources, hospital consultants and in particular the community pharmacist. When the use and influence of drug information sources by GPs was examined, the community pharmacist was given a relatively low rating as a source but a high rating, similar to that of the consultant, for helpfulness. Influences are needed to improve prescribing and reduce the incidence of iatrogenic disease for the benefit of the patient. The education and expertise of pharmacists and their familiarity with local prescribing habits places them in a unique position to meet the needs of local GPs. As 96.5% of the public always or nearly always take their prescriptions to the same pharmacy, patient medication records, now kept by 77.5% of pharmacies, provide a valuable check on the appropriateness and safety of patients' medication. The barriers to the pharmacist's greater involvement were shown to be suspicion by GPs of pharmacists' motivation, isolation of many community pharmacists, difficulties in leaving the pharmacy for domiciliary visits, residential home care and GP practice meetings. These barriers must be lowered if the pharmacist is to have a greater influence and involvement. It was concluded that changes are necessary in pharmaceutical education, staff training, organisation and remuneration. Some changes in the targeting of remuneration to the pharmaceutical care services provided and registration of patients with pharmacies would contribute greatly to these aims.
Resumo:
The number of fatal accidents in the agricultural, horticultural and forestry industry in Great Britain has declined from an annual rate of about 135 in the 1960's to its current level of about 50. Changes to the size and makeup of the population at risk mean that there has been no real improvement in fatal injury incidence rates for farmers. The Health and Safety Executives' (HSE) current system of accident investigation, recording, and analysis is directed primarily at identifying fault, allocating blame, and punishing wrongdoers. Relatively little information is recorded about the personal and organisational factors that contributed to, or failed to prevent accidents. To develop effective preventive strategies, it is important to establish whether errors by the victims and others, occur at the skills, rules, or knowledge level of functioning: are violations of some rule or procedure; or stem from failures to correctly appraise, or control a hazard. A modified version of the Hale and Glendon accident causation model was used to study 230 fatal accidents. Inspectors' original reports were examined and expert judgement applied to identify and categorise the errors committed by each of the parties involved. The highest proportion of errors that led directly to accidents occurred whilst the victims were operating at the knowledge level. The mix and proportion of errors varied considerably between different classes of victim and kind of accident. Different preventive strategies will be needed to address the problem areas identified.
Resumo:
Congenital nystagmus is an ocular-motor disorder characterised by involuntary, conjugated and bilateral to and fro ocular oscillations. In this study a method to recognise automatically jerk waveform inside a congenital nystagmus recording and to compute foveation time and foveation position variability is presented. The recordings were performed with subjects looking at visual targets, presented in nine eye gaze positions; data were segmented into blocks corresponding to each gaze position. The nystagmus cycles were identified searching for local minima and maxima (SpEp sequence) in intervals centred on each slope change of the eye position signal (position criterion). The SpEp sequence was then refined using an adaptive threshold applied to the eye velocity signal; the outcome is a robust detection of each slow phase start point, fundamental to accurately compute some nystagmus parameters. A total of 1206 slow phases was used to compute the specificity in waveform recognition applying only the position criterion or adding the adaptive threshold; results showed an increase in negative predictive value of 25.1% using both features. The duration of each foveation window was measured on raw data or using an interpolating function of the congenital nystagmus slow phases; foveation time estimation less sensitive to noise was obtained in the second case. © 2010.
Resumo:
Objective: To introduce a new technique for co-registration of Magnetoencephalography (MEG) with magnetic resonance imaging (MRI). We compare the accuracy of a new bite-bar with fixed fiducials to a previous technique whereby fiducial coils were attached proximal to landmarks on the skull. Methods: A bite-bar with fixed fiducial coils is used to determine the position of the head in the MEG co-ordinate system. Co-registration is performed by a surface-matching technique. The advantage of fixing the coils is that the co-ordinate system is not based upon arbitrary and operator dependent fiducial points that are attached to landmarks (e.g. nasion and the preauricular points), but rather on those that are permanently fixed in relation to the skull. Results: As a consequence of minimizing coil movement during digitization, errors in localization of the coils are significantly reduced, as shown by a randomization test. Displacement of the bite-bar caused by removal and repositioning between MEG recordings is minimal (∼0.5 mm), and dipole localization accuracy of a somatosensory mapping paradigm shows a repeatability of ∼5 mm. The overall accuracy of the new procedure is greatly improved compared to the previous technique. Conclusions: The test-retest reliability and accuracy of target localization with the new design is superior to techniques that incorporate anatomical-based fiducial points or coils placed on the circumference of the head. © 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
This thesis covers two major aspects of pharmacy education; undergraduate education and pre-registration training. A cohort of pharmacy graduates were surveyed over a period of four years, on issues related to undergraduate education, pre-registration training and continuing education. These graduates were the first-ever to sit the pre-registration examination. In addition, the opinions of pre-registration tutors were obtained on pre-registration training, during the year that competence-based assessment was introduced. It was concluded that although the undergraduate course provided a broad base of knowledge suitable for graduates in all branches of pharmacy, several issues were identified which would require attention in future developments of the course. These were: 1. the strong support for the expansion of clinical, social and practice-based teaching. 2. the strong support to retain the scientific content to the same extent as in the three-year course. 3. a greater use of problem-based learning methods. The graduates supported the provision of a pre-registration continuing education course to help prepare for the examination and in areas inadequately covered in the undergraduate course. There was also support for the introduction of some form of split branch training. There was no strong evidence to suggest that the training had been an application of undergraduate education. In general, competence-based training was well regarded by tutors as an appropriate and effective method of skill assessment. However, community tutors felt it was difficult to carry out effectively due to day-to-day time constraints. The assistant tutors in hospital pharmacy were found to have a very important role in provision of training, and should be adequately trained and supported. The study recommends the introduction of uniform training and a quality assurance mechanism for all tutors and assistants undertaking this role.
Resumo:
The work presented in this thesis is divided into two distinct sections. In the first, the functional neuroimaging technique of Magnetoencephalography (MEG) is described and a new technique is introduced for accurate combination of MEG and MRI co-ordinate systems. In the second part of this thesis, MEG and the analysis technique of SAM are used to investigate responses of the visual system in the context of functional specialisation within the visual cortex. In chapter one, the sources of MEG signals are described, followed by a brief description of the necessary instrumentation for accurate MEG recordings. This chapter is concluded by introducing the forward and inverse problems of MEG, techniques to solve the inverse problem, and a comparison of MEG with other neuroimaging techniques. Chapter two provides an important contribution to the field of research with MEG. Firstly, it is described how MEG and MRI co-ordinate systems are combined for localisation and visualisation of activated brain regions. A previously used co-registration methods is then described, and a new technique is introduced. In a series of experiments, it is demonstrated that using fixed fiducial points provides a considerable improvement in the accuracy and reliability of co-registration. Chapter three introduces the visual system starting from the retina and ending with the higher visual rates. The functions of the magnocellular and the parvocellular pathways are described and it is shown how the parallel visual pathways remain segregated throughout the visual system. The structural and functional organisation of the visual cortex is then described. Chapter four presents strong evidence in favour of the link between conscious experience and synchronised brain activity. The spatiotemporal responses of the visual cortex are measured in response to specific gratings. It is shown that stimuli that induce visual discomfort and visual illusions share their physical properties with those that induce highly synchronised gamma frequency oscillations in the primary visual cortex. Finally chapter five is concerned with localization of colour in the visual cortex. In this first ever use of Synthetic Aperture Magnetometry to investigate colour processing in the visual cortex, it is shown that in response to isoluminant chromatic gratings, the highest magnitude of cortical activity arise from area V2.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
The internal optics of the recent models of the Shin-Nippon SRW-5000 autorefractor (also marketed as the Grand Seiko WV-500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field-of-view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW-5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root-mean-square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on-line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses. © 2004 The College of Optometrists.
Resumo:
A newly released commercial autorefractor, the Shin-Nippon SRW-5000 (Japan), has been found to be valid compared to subjective refraction and repeatable over a wide prescription range. Its binocular open field-of-view allows the accommodative state to be monitored while a natural environment is viewed. In conventional static mode, the device can take up to 45 readings in 1min using digital image analysis of the reflected retinal image of a measurement ring. Continuous on-line analysis of the ring provides high (up to 60Hz) temporal resolution of the refractive state to an accuracy of <0.001D. Pupil size can also be analysed to a resolution of <0.001mm. The measurement of accommodation and pupil size was relatively unaffected by eccentricity of viewing up to ±10° and instrument focusing inaccuracies of ±5mm. The resolution properties of the analysis are shown to be ideal for measurement of dynamic accommodation and pupil responses. Copyright © 2001 The College of Optometrists.
Resumo:
Long term recording of biomedical signals such as ECG, EMG, respiration and other information (e.g. body motion) can improve diagnosis and potentially monitor the evolution of many widespread diseases. However, long term monitoring requires specific solutions, portable and wearable equipment that should be particularly comfortable for patients. The key-issues of portable biomedical instrumentation are: power consumption, long-term sensor stability, comfortable wearing and wireless connectivity. In this scenario, it would be valuable to realize prototypes using available technologies to assess long-term personal monitoring and foster new ways to provide healthcare services. The aim of this work is to discuss the advantages and the drawbacks in long term monitoring of biopotentials and body movements using textile electrodes embedded in clothes. The textile electrodes were embedded into garments; tiny shirt and short were used to acquire electrocardiographic and electromyographic signals. The garment was equipped with low power electronics for signal acquisition and data wireless transmission via Bluetooth. A small, battery powered, biopotential amplifier and three-axes acceleration body monitor was realized. Patient monitor incorporates a microcontroller, analog-to-digital signal conversion at programmable sampling frequencies. The system was able to acquire and to transmit real-time signals, within 10 m range, to any Bluetooth device (including PDA or cellular phone). The electronics were embedded in the shirt resulting comfortable to wear for patients. Small size MEMS 3-axes accelerometers were also integrated. © 2011 IEEE.