30 resultados para Rational objective
em Aston University Research Archive
Resumo:
Purpose. To convert objective image analysis of anterior ocular surfaces into recognisable clinical grades, in order to provide a more sensitive and reliable equivalent to current subjective grading methods; a prospective, randomized study correlating clinical grading with digital image assessment. Methods. The possible range of clinical presentations Of bulbar and palpebral hyperaemia, palpebral roughness and corneal staining were represented by 4 sets of 10 images. The images were displayed in random order and graded by 50 clinicians using both subjective CCLRU and Efron grading scales. Previously validated objective image analysis was performed 3 times oil each of the 40 images. Digital measures included edge-detection and relative-coloration components. Step-wise regression analysis determined correlations between the average subjective grade and the objective image analysis measures. Results. Average subjective grades Could be predicted by a combination of the objective image analysis components. These digital ``grades'' accounted for between 69%, (for Efron scale-graded palpebral redness) and 98% (for Efron scale-graded bulbar hyperaemia) of the subjective variance. Conclusions. The results indicate that clinicians may use a combination of vessel areas and overall hue in their judgment of clinical severity for certain conditions. Objective grading call take these aspects into account, and be used to predict an average ``objective grade'' to be used by a clinician in describing the anterior eye. These measures are more sensitive and reliable than subjective grading while still utilizing familiar terminology, and can be applied in research or practice to improve the detection, and monitoring of ocular surface changes.
Resumo:
Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was
Resumo:
Purpose: To examine the objective clinical performance of ‘comfort-enhanced’ daily disposable contact lenses over a 16-h day. Methods: Four contact lenses (Hilafilcon B, Etafilcon A Plus, Nelfilcon A and Nelfilcon A Plus) were evaluated in an investigator masked, open label trial at the end of a week’s bilateral wear. Pre-lens noninvasive tear break-up time (PL-NITBUT), tear prism height, bulbar hyperaemia and ocular surface temperature (OST) were measured with the lens in situ at 8, 12 and 16 h of wear. Results: There was no difference between how many hours the lenses types were worn each day (F = 0.90, p = 0.44). The PL-NITBUT decreased with the duration of daily lens wear (F = 32.0, p < 0.001) and was more stable with Nelfilcon A Plus (F = 6.00, p = 0.002) than with the other lenses evaluated. Bulbar blood vessels increased in coverage (F = 11.5, p < 0.001) but not overall redness (F = 0.0, p = 0.99) with the duration of daily lens wear, but there was no difference between the lenses (p > 0.05). The tear prism height decreased with the duration of daily wear (F = 27.0, p < 0.001) and differed between lenses (F = 2.9, p = 0.04). The OST decreased with the duration of lens wear (F = 119.7, p < 0.001) and was reduced by daily disposable lens wear (F = 7.88, p < 0.001), but did not differ between lenses (F = 0.88, p = 0.45). Conclusions: Objective measures of tear film indicated a difference between the lenses evaluated for PLNITBUT and tear prism height, but not for wearing time or bulbar conjunctival hyperaemia. Therefore clinical benefits of daily disposable ‘comfort enhancing’ contact lenses can be measured, but challenges remain in producing contact lenses that do not compromise anterior eye physiology over the whole day. 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
In industrialised countries age-related macular disease (ARMD) is the leading cause of visual loss in older people. Because oxidative stress is purported to be associated with an increased risk of disease development the role of antioxidant supplementation is of interest. Lutein is a carotenoid antioxidant that accumulates within the retina and is thought to filter blue light. Increased levels of lutein have been associated with reduced risk of developing ARMD and improvements in visual and retinal function in eyes with ARMD. The aim of this randomised controlled trial (RCT) was to investigate the effect of a lutein-based nutritional supplement on subjective and objective measures of visual function in healthy eyes and in eyes with age-related maculopathy (ARM) – an early form of ARMD. Supplement withdrawal effects were also investigated. A sample size of 66 healthy older (HO), healthy younger (HY), and ARM eyes were randomly allocated to receive a lutein-based supplement or no treatment for 40 weeks. The supplemented group then stopped supplementation to look at the effects of withdrawal over a further 20 weeks. The primary outcome measure was multifocal electroretinogram (mfERG) N1P1 amplitude. Secondary outcome measures were mfERG N1, P1 and N2 latency, contrast sensitivity (CS), Visual acuity (VA) and macular pigment optical density (MPOD). Sample sizes were sufficient for the RCT to have an 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures when the healthy eye groups were combined, and CS, VA and mfERG in the ARM group. This RCT demonstrates significant improvements in MPOD in HY and HO supplemented eyes. When HY and HO supplemented groups were combined, MPOD improvements were maintained, and mfERG ring 2 P1 latency became shorter. On withdrawal of the supplement mfERG ring 1 N1P1 amplitude reduced in HO eyes. When HO and HY groups were combined, mfERG ring 1 and ring 2 N1P1 amplitudes were reduced. In ARM eyes, ring 3 N2 latency and ring 4 P1 latency became longer. These statistically significant changes may not be clinically significant. The finding that a lutein-based supplement increases MPOD in healthy eyes, but does not increase mfERG amplitudes contrasts with the CARMIS study and contributes to the debate on the use of nutritional supplementation in ARM.
Resumo:
PURPOSE: To assess the repeatability of an objective image analysis technique to determine intraocular lens (IOL) rotation and centration. SETTING: Six ophthalmology clinics across Europe. METHODS: One-hundred seven patients implanted with Akreos AO aspheric IOLs with orientation marks were imaged. Image quality was rated by a masked observer. The axis of rotation was determined from a line bisecting the IOL orientation marks. This was normalized for rotation of the eye between visits using the axis bisecting 2 consistent conjunctival vessels or iris features. The center of ovals overlaid to circumscribe the IOL optic edge and the pupil or limbus were compared to determine IOL centration. Intrasession repeatability was assessed in 40 eyes and the variability of repeated analysis examined. RESULTS: Intrasession rotational stability of the IOL was ±0.79 degrees (SD) and centration was ±0.10 mm horizontally and ±0.10 mm vertically. Repeated analysis variability of the same image was ±0.70 degrees for rotation and ±0.20 mm horizontally and ±0.31 mm vertically for centration. Eye rotation (absolute) between visits was 2.23 ± 1.84 degrees (10%>5 degrees rotation) using one set of consistent conjunctival vessels or iris features and 2.03 ± 1.66 degrees (7%>5 degrees rotation) using the average of 2 sets (P =.13). Poorer image quality resulted in larger apparent absolute IOL rotation (r =-0.45,P<.001). CONCLUSIONS: Objective analysis of digital retroillumination images allows sensitive assessment of IOL rotation and centration stability. Eye rotation between images can lead to significant errors if not taken into account. Image quality is important to analysis accuracy.
Resumo:
Objectives: To compare the recognized defined daily dose per 100 bed-days (DDD/100 bed-days) measure with the defined daily dose per finished consultant episode (DDD/FCE) in a group of hospitals with a variety of medicines management strategies. To compare antibiotic usage using the above indicators in hospitals with and without electronic prescribing systems. Methods: Twelve hospitals were used in the study. Nine hospitals were selected and split into three cohorts (three high-scoring, three medium-scoring and three low-scoring) by their 2001 medicines management self-assessment scores (MMAS). An additional cohort of three electronic prescribing hospitals was included for comparison. MMAS were compared to antibiotic management scores (AMS) developed from a questionnaire relating specifically to control of antibiotics. FCEs and occupied bed-days were obtained from published statistics and statistical analyses of the DDD/100 bed-days and DDD/FCE were carried out using SPSS. Results: The DDD/100 bed-days varied from 81.33 to 189.37 whilst the DDD/FCE varied from 2.88 to 7.43. The two indicators showed a high degree of correlation with r = 0.74. MMAS were from 9 to 22 (possible range 0-23) and the AMS from 2 to 13 (possible range 0-22). The two scores showed a high degree of correlation with r = 0.74. No correlation was established between either indicator and either score. Conclusions: The WHO indicator for medicines utilization, DDD/100 bed-days, exhibited the same level of conformity as that exhibited from the use of the DDD/FCE indicating that the DDD/FCE is a useful additional indicator for identifying hospitals which require further study. The MMAS can be assumed to be an accurate guide to antibiotic medicines management controls. No relationship has been found between a high degree of medicines management control and the quantity of antibiotic prescribed. © The British Society for Antimicrobial Chemotherapy; 2004 all rights reserved.
Resumo:
Objectives: To develop an objective measure to enable hospital Trusts to compare their use of antibiotics. Design: Self-completion, postal questionnaire with telephone follow up. Sample: 4 hospital trusts in the English Midlands. Results: The survey showed that it was possible to collect data concerning the number of Defined Daily Doses (DDD's) of quinolone antibiotic dispensed per Finished Consultant Episode (FCE) in each Trust.. In the 4 trusts studied the mean DDD/FCE was 0.197 (range 0.117 to 0.258). This indicates that based on a typical course length of 5 days, 3.9% of patient episodes resulted in the prescription of a quinolone antibiotic. Antibiotic prescribing control measures in each Trust were found to be comparable. Conclusion: The measure will enable Trusts to objectively compare their usage of quinolone antibiotics and use this information to carry out clinical audit should differences be recorded. This is likely to be applicable to other groups of antibiotics.
Resumo:
The thesis addresses the relative importance of factors affecting working-class school-leavers' post-compulsory education transitions into post-sixteen education, training, employment and unemployment. It focuses on school-leavers choosing to enter the labour market, whether successfully or not and the influences affecting this choice. Methodologically, the longitudinal approach followed young people from before they left school to a period of months after. Discrepancies between young people's intended and actual destinations emphasised the diverse influences on post-sixteen transitions. These influences were investigated through a dynamic multi-method approach, drawing from quantitative and qualitative methodologies providing depth and insight while locating the research within a structural framework, allowing a comparison with local and national trends. Two crucial factors of school and gender affected young people's intended and actual post-sixteen directions. School policy, including treatment of disaffected pupils and recruitment to a large, on-site sixth form, influenced the number of pupils opting to continue their education. Girls were more likely to continue education after the end of compulsory schooling and gave different reasons to boys for doing so. Family and peer groups were influential, helping young people develop a 'horizon for action' incorporating habitus and subjective preferences that specified acceptable post-sixteen directions. These influences operated within the context of the local labour market. Perception of the latter rather than actual conditions informed post-sixteen decisions; however, labour market reality influenced the success of the school-leavers' endeavours. The research found that the economics-based rational choice model of decision-making did not apply to many working class school-leavers. The cohort made pragmatically rational decisions dependent on their 'horizon for action'. based on partial, occasionally inaccurate information. Policy recommendations consider the careers service and structure or school sixth forms as aiding successful transitions from compulsory education into education, employment or training. The maintenance allowance may be ineffectual in tackling its objective of social inclusion.
Resumo:
Aluminium (Al) is known to be neurotoxic and has been associated with the aetiology of Alzheimer's Disease. To date, only desferrioxamine (DFO), a trihydroxamic acid siderophore has been used in the clinical environment for the removal of Al from the body. However, this drug is expensive, orally inactive and is associated with many side effects. These studies employed a theoretical approach, with the use of quantum mechanics (QM) via semi-empirical molecular orbital (MO) calculations, and a practical approach using U87-MG glioblastoma cells as a model for evaluating the influence of potential chelators on the passage of aluminium into cells. Preliminary studies involving the Cambridge Structural Database (CSD) identified that Al prefers binding to bidentate ligands in a 3:1 manner, whereby oxygen was the exclusive donating atom. Statistically significant differences in M-O bond lengths when compared to other trivalent metal ions such as Fe3+ were established and used as an acceptance criterion for subsequent MO calculations. Of the semi-empirical methods parameterised for Al, the PM3 Hamiltonian was found to give the most reliable final optimised geometries of simple 3:1 Al complexes. Consequently the PM3 Hamiltonian was used for evaluating the Hf of 3:1 complexes with more complicated ligands. No correlation exists between published stability constants and individual parameters calculated via PM3 optimisations, although investigation of the dicarboxylates reveals a correlation of 0.961 showing promise for affinity prediction of closely related ligands. A simple and inexpensive morin spectrofluorescence assay has been developed and optimised producing results comparable to atomic absorption spectroscopy methods for the quantitative analysis of Al. This assay was used in subsequent in vitro models, initially on E. coli, which indicated that Al inhibits the antimicrobial action of ciprofloxacin, a potent quinolone antibiotic. Ensuing studies using the second model, U87-MG cells, investigated the influence of chelators on the transmembrane transport of Al, identifying 1,2-diethylhydroxypyridin-4-one as a ligand showing greatest potential for chelating Al in the clinical situation. In conclusion, these studies have explored semi-empirical MO Hamiltonians and an in-vitro U87-MG cell line, both as possible methods for predicting effective chelators of Al.
Resumo:
This thesis set out to develop an objective analysis programme that correlates with subjective grades but has improved sensitivity and reliability in its measures so that the possibility of early detection and reliable monitoring of changes in anterior ocular surfaces (bulbar hyperaemia, palpebral redness, palpebral roughness and corneal straining) could be increased. The sensitivity of the program was 20x greater than subjective grading by optometrists. The reliability was found to be optimal (r=1.0) with subjective grading up to 144x more variable (r=0.08). Objective measures were used to create formulae for an overall ‘objective-grade’ (per surface) equivalent to those displayed by the CCLRU or Efron scales. The correlation between the formulated objective verses subjective grades was high, with adjusted r2 up to 0.96. Determination of baseline levels of objective grade were investigated over four age groups (5-85years n= 120) so that in practice a comparison against the ‘normal limits’ could be made. Differences for bulbar hyperaemia were found between the age groups (p<0.001), and also for palpebral redness and roughness (p<0.001). The objective formulae were then applied to the investigation of diurnal variation in order to account for any change that may affect the baseline. Increases in bulbar hyperaemia and palpebral redness were found between examinations in the morning and evening. Correlation factors were recommended. The program was then applied to clinical situations in the form of a contact lens trial and an investigation into iritis and keratoconus where it successfully recognised various surface changes. This programme could become a valuable tool, greatly improving the chances of early detection of anterior ocular abnormalities, and facilitating reliable monitoring of disease progression in clinical as well as research environments.
Resumo:
Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.
Resumo:
The starting point of this research was the belief that manufacturing and similar industries need help with the concept of e-business, especially in assessing the relevance of possible e-business initiatives. The research hypotheses was that it should be possible to produce a systematic model that defines, at a useful level of detail, the probable e-business requirements of an organisation based on objective criteria with an accuracy of 85%-90%. This thesis describes the development and validation of such a model. A preliminary model was developed from a variety of sources, including a survey of current and planned e-business activity and representative examples of e-business material produced by e-business solution providers. The model was subject to a process of testing and refinement based on recursive case studies, with controls over the improving accuracy and stability of the model. Useful conclusions were also possible as to the relevance of e-business functions to the case study participants themselves. Techniques were evolved to synthesise the e-business requirements of an organisation and present them at a management summary level of detail. The results of applying these techniques to all the case studies used in this research were discussed. The conclusion of the research was that the case study methodology employed was successful. A model was achieved suitable for practical application in a manufacturing organisation requiring help with a requirements definition process.
Resumo:
Lutein and zeaxanthin are lipid-soluble antioxidants found within the macula region of the retina. Links have been suggested between increased levels of these carotenoids and reduced risk for age-related macular disease (ARMD). Therefore, the effect of lutein-based supplementation on retinal and visual function in people with early stages of ARMD (age-related maculopathy, ARM) was assessed using multi-focal electroretinography (mfERG), contrast sensitivity and distance visual acuity. A total of fourteen participants were randomly allocated to either receive a lutein-based oral supplement (treated group) or no supplement (non-treated group). There were eight participants aged between 56 and 81 years (65·50 (sd 9·27) years) in the treated group and six participants aged between 61 and 83 years (69·67 (sd 7·52) years) in the non-treated group. Sample sizes provided 80 % power at the 5 % significance level. Participants attended for three visits (0, 20 and 40 weeks). At 60 weeks, the treated group attended a fourth visit following 20 weeks of supplement withdrawal. No changes were seen between the treated and non-treated groups during supplementation. Although not clinically significant, mfERG ring 3 N2 latency (P= 0·041) and ring 4 P1 latency (P= 0·016) increased, and a trend for reduction of mfERG amplitudes was observed in rings 1, 3 and 4 on supplement withdrawal. The statistically significant increase in mfERG latencies and the trend for reduced mfERG amplitudes on withdrawal are encouraging and may suggest a potentially beneficial effect of lutein-based supplementation in ARM-affected eyes. Copyright © 2012 The Authors.
Resumo:
This review provides an insight into the various opportunities for vaccine intervention, analysis of strategies for vaccine development, vaccine ability to modulate immune responses and resultant rational vaccine design. In addition, wider aspects are considered, such as biotechnological advances, advances in immunological understanding and host-pathogen interactions. The key question addressed here is, with all our research and understanding, have we reached a new echelon in vaccine development, that of rational design? ©2005 Elsevier Ltd. All rights reserved.